Türkiye, Istanbul
...Corrosion resistant, light Aluminium heat exchanger Efficiency upto %109 Five capacities options (70 , 95, 125, 155, 190* kW) Cascade system with 16 boilers 17 modulation ration Workıng pressure 6 bar High combustion performance with low exhaust emission Different zone controls with Siemens control panel Compability with Open Therm ve BUS comunication systems External chimney flap Low noise level Easy to use and maintenance...
Germany, Kirchzarten
...The PSD 43 series actuators are mechatronic systems with integrated drive, bus interface, and battery-free absolute measurement system. They are ideal for adjusting machine axes intended for format changes. Thanks to the stepper motor with integrated control and bus communication, it is possible to combine low torque with very high speeds. Rotary switch for actuator addressing (not for IO-Link...
France, Neuillé
...noise detection calls, caller identification...) > Access and link intercom (building access, corridors, airlocks...) > Visiting room intercom (listening and recording capabilities) > Counter intercom (package/document handling...) > Graphical supervision of communications, access, and alarms, video control > Acoustic quality and robustness > Bus, star, and IP architecture > Interoperable solutions that integrate seamlessly into centralized management systems...
Belgium, Waterloo
... of PA amplifiers, MPA multiplexers, and PAB 'bus' amplifiers that, in combination with the appropriate sensor, form a unique and complete system. Distance up to 70m Control LED Wide selection of housings Connection via molded cable or connector Distance up to 70m Power supply 230VAC, 115VAC, 24VAC/VDC · Automatic or manual sensitivity adjustment...
...The master concentrator module CT-V900-ATR is the heart of the Centaur access control system. All inputs and outputs, readers, and expansion modules are directly connected to the module. Systems with multiple controllers are interconnected via RS-485 serial communication bus. The distributed database architecture allows each controller to make decisions in a few milliseconds without querying the...
...A burglary alarm system is MORE than just an "alarm system." Whether in analog, BUS, or wireless technology, a burglary alarm system provides intelligent information for you as the operator, as well as for a security service. In addition to the typical detectors of a burglary alarm system, more and more technical elements are gaining importance. Take advantage of these opportunities and thus...
...The transfer car is based on the innovative DAMBACH Shuttle technology, using power caps for energy storage – making bus bars unnecessary. However, if required a traditional energy supply via bus bar or cable chain is possible. The transfer car can be equipped with up to two load handling devices or with roller or chain conveyors. Good throughput rates Low height Low installation requirements With one or two load-handling units With optional transfer unit for safe transfer of mesh box pallets...
Germany, Rostock
... and interpreters for Python, Perl, and Ruby are available. The data logger is designed as a data acquisition device for use in buses and trains. It is equipped with railway interfaces (IBIS-BUS). The data logger can be operated in conjunction with the piSmart Gateway and pironex IoT Portal. This enables you to read and analyze your collected information and measurement data.
Türkiye, Istanbul
...Multi-Jet Dry Dial (Domestic) Cold Water Meters / 360° rotatable cover / Display on 5 roller counter mechanism m³ and 4-roller for litres / %100 Brass materials body / Non return valve / Magnetic field protection / From DN15 ~ DN50 dimension / Measuring range R100 - Class B / Pulse, M-bus, RF (Radio Frequency) output interfaces (optional) / Hermetically sealed register (IP68...
ufs.country_names.RU, Novoivanovskoe
...THOR represents one or two superpowerful loudspeakers housed in spheroidal structures made of titanium-steel alloy. The system is suitable for absolutely any modern car. You will only need CAN-bus of your car`s engine to install THOR system. It is CAN-bus via which a complete synchronization of electronic exhaust system and your engine operation is performed. Installation warranty is two years...
China, Sichuan Province
...The CN-8033 EtherCAT I/O module supports standard EtherCAT protocol access. The adapter supports a Max. input of 1024 bytes and a Max. output of 1024 bytes. It supports 32 pcs of extended IO modules. Hardware Specification System Power: Nominal 24Vdc, Range-9-36Vdc Protection: Overcurrent Protection, Reverse Protection: YES Power Consumption:110mA@24Vdc Internal BUS Supply Current:Max...
Germany, Düsseldorf
Germany, Kevelaer
... (pls. observe the installation instructions provided in the "abZ") EN 795:2012, C & CEN/TS 16415:2013 Compatible with most ABS Safety system supports Suitable for Installation on virtually any surface 8 or 6 mm stainless steel cable (V4A) Designed for facades, crane ways, filling plants, industrial, bus, plane and maintenance halls etc. Simultaneous protection for up to 4 individuals...
China, Shenyang
...designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output. Connect different control systems (Siemens, Emerson, Schneider Electronics, ABB, Yokogawa, Rockwell, etc.)...
Türkiye, Bursa
...Since 1983, we have been producing spare parts for bus and minibus automatic door systems, combining our modern and high-quality production approach with our strong team and commitment to quality. Today, we continue our production at a rapid pace in our factory, which has a closed area of two thousand five hundred square meters, established on an eighteen-acre site. Our areas of activity...
Belgium, Ans ( Liege )
...Power module and NX bus extension, unique, board, Power outputs: 3 Output voltage: 13.85V DC, Output current: max 2A, siren output max 2A (monitored), Total output current: max 2.5A (0.5A battery + 2A power & siren output), Tamper input: NF (unbalanced) Bus extension: extra 800m, Power supply voltage: 16.5V AC (transformer 51-0003 optional), Consumption: 10mA, Battery: max 12V/18Ah, Dimensions (LxHxD): 236x86x30mm...
France, Fondettes
... sounds that suit you best. Moreover, thanks to its IP67 waterproof rating and IK08 shock resistance, the product adapts to all your environments, even the harshest ones. As a result, it is a product that will provide you with safety, productivity, and comfort. The audible and easily understandable information ensures better awareness of the information. It is a driving aid that is becoming essential. The adaptalarm comes in 3 technical solutions to best fit your needs: Can Only, Can +, and Bus Free.
ufs.country_names.RU, Zarechny
... for: - the absence of special authorization for this frequency band, enabling the application of barriers in several countries around the world - immunity to electromagnetic interference - a narrow detection zone that covers more applications of barriers. The advanced configuration of the barriers (Windows) via USB ensures optimal operating mode, including connection via an RS485 bus from a remote...
France, Lormont-Bordeaux
... the buses, trip consumption, and transport network scheduling, our program can adapt the charging plan for the buses and the bus network usage plan. This AI enables the city to consume a minimum amount of electricity steadily over time. This ensures the sustainability of the batteries in both the short and long term by managing the bus replenishment network while achieving savings within a framework of sustainable development.
Spain, Paterna
...The module has a single output of 100 kW and a frequency range of 10 to 400 kHz allowing easy paralleling for power upgrading. The w100k400 is fed with a DC voltage between 500 to 650 VDC.The module provides all the required features needed in an induction heating power supply, and also provides a CAN Bus Communication output for the communication with a dedicated HMI. The output of the module feds directly the heating station (output transformer, capacitor bank and heating inductor).
Germany, Celle
...Goliath Intercom System Basic – the new line from Goliath is characterized by its simplicity. The connection is made using just 2 wires, allowing you to utilize existing wiring for installation. No additional cables need to be laid. Even in the Goliath Intercom System Basic line, you won't miss out on any features. Messages from visitors can be recorded, and the remote door opening function is also available to you. Additionally, caller lists can be created, and different ringtones can be selected for each door station.
Germany, Weilburg
...ISO14443/ISO15693 DESK READER • for the identification of 13.56MHz transponders • 144 x 84 x 18mm (LxWxH) • Integrated antenna • Interface: USB 2.0 • Power supply: 5 V, USB bus powered • Transponder: ISO15693, ISO14443-A/-B • Application examples: - Identification of files and documents - Identification of rental items - Libraries • Special features: - Anti-collision function - Polling mode...
Italy, Sangiovanni Valdarno
... third rows of seats to create more space in the cargo area. We also offer models with seat attachments equipped with an ISO-FIX system to safely transport infants on board the vehicle. All our models can be driven with just a B license and are very easy to maneuver, as well as being equipped with automated parking systems with sensors, air conditioning, climate control, snow chains, cigar lighter sockets, and USB ports so you can listen to your music whenever you want using a USB flash drive.
...Receiver compatible with the entire range of JMei transmitters. The JMei RECF receiver is the new ideal control interface for your embedded and industrial applications. Create your RECF receiver based on the options provided in the downloadable datasheet via the links above. Complying with the latest industrial standards, the receiver can be installed in the most demanding technical areas at all...
Germany, Crailsheim
...Manufacturing of bus module systems for silo level monitoring and filling systems Bus module system for silo level monitoring, filling systems,... · Load cell interface LCI-M · Housing 85mm x 65mm x 25mm · DIN rail mounting · Load cell connection 1 · Connection type terminal technology, cold welded · Sensitivity 1mV/V-3.6mV/V · Maximum number of measurements 4000/s · Power supply via power...
... Systems are intelligent solutions for power distribution and digitalization in vehicles with CAN communication. The SCS portfolio includes standardized hardware combined with flexibly adaptable software for easy vehicle modernization and system integration. Comprehensive diagnostic functions enable early fault detection and reduce or prevent consequential damages, vehicle breakdowns, and downtime. With flexible and compact CAN controllers, existing CAN networks can be easily and quickly expanded.
...Double-acting support cylinders are available in various sizes tailored to your load conditions. Stroke lengths can be chosen freely. Integrated safety valves and oil connections in the cylinder base without external oil supply. Valve block control via valve control module and tilt sensors with manual control unit. Can be integrated into a CAN bus system. Robust components, specially designed for use in mobile applications. 12-24 V. Power supply for vehicle electrical systems. Compact unit for oil supply for vehicles without hydraulics.
Germany, Montabaur
...SmartHome-compatible power strips for controlling underfloor heating / cooling systems for 6, 10, and 12 heating circuits - 24 / 230 V supply voltage. Alternatively available as a bus or radio system.
...The compact single-jet heat meter Dialog WZ R5.M is designed to measure the consumed heat energy in closed heating systems. Measuring unit approved up to 120° C Temperature difference: 3 ... 90 K Approval for symmetrical installation of temperature sensors 16-bit microcontroller 8-digit LCD 2 buttons for display switching Measuring unit housing removable and...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play