United Kingdom, Bedfordshire
...The ZWR+ is 5 times more productive than any standard measurement of SF6 gas purity in gas insulated switchgear and high voltage equipment. Delivering laboratory-standard accuracy, stability and repeatability in the field: the ZWR+ provides automatic, multi-analysis gas quality testing using advanced IR measurement technology for the fastest and simplest, zero-emission measurement solution in GIS preventative maintenance. ...
Germany, Rain
... product, such as containers made of the material 1.4404 (316L) or 1.4435 (316L defined delta ferrite content) Tanks and pipes cooled, heated and/or insulated ("chloride-free") Pipe dimensions according to DIN 11866 Aseptic pipe connections as clamp connections according to DIN 32676 Easy assembly and disassembly...
Germany, Saarbrücken
...Robot cover manufactured with specific materials (fabrics and accessories) and developed to guarantee the lowest thermal conductivity. Innovative, two-layer fabrics that comply with the ISO 9001 quality standard (TÜV certification in the 2015 version). Insulated and sealed protective cover with air intake on axis 1 and axis 4 rotating rings Built-in dehumidifier – no moisture build-up. High-quality robot cover made of TKS-ALU aluminum fabric (M1 fire rating). Repairable and flexible robot protection that guarantees the robot’s freedom of movement, even in climatic chambers.
France, Montmirail
... offered by axon' are made with tin plated copper, nickel plated copper, copper alloy, or silver plated copper conductor. They are insulated with special halogen free insulating material including Poliax™, Neutrax™, Polyimide, Axon Special Compound. This is an ideal solution for cabling of buildings, trains, subways, ships, industrial premises and all public places where security of people and material have to be assured non propagation of fire and flame:compliance with IEC standard...
... dust or liquid from passing through. We offer a wide range of standard grommets, but we specialize in custom products based on the technical requirements and drawings provided by the customer. EPDM grommets are excellent for UV and ozone resistance and can be used outdoors. NR/SBR grommets are highly abrasion-resistant and exhibit low compression set, but are less suitable for outdoor use.
... - Completely insulated, encapsulated design - Impact forces are transmitted into the foundation slab - Fully insulated even during loading - Green Plus package included as standard, up to 70% energy savings - Ergo Plus package included as standard - NCI on board - Accessibility Technical Data - Rated load according to EN 1398: 60 kN - Nominal widths: 2000, 2250 mm - Nominal lengths: 2000, 2500, 3000 mm - Construction heights: 830, 900 mm - Extension lengths: 700, 1000 mm - Power supply: 3 N - 400 V/50 Hz/16 A - Protection class: IP 65 - Motor power: max. 1.5 kW...
Romania, Bucharest
...Endowments of Elite Turbo Plus Model + Fibre optic STARS20 illumination STANDARD STRUCTURE Acrylic crustmodel 195x195x72 armoured and thermal insulated color, 3 hip bath seats + 2 flat seats. Metal bolstertreated anticorrosive with adjustable legs 1 pump with 2 speeds 1.5HPfor recirculating – filtration – warming and hydro-massage dedicated to the 2 flat seats 1 pump with 1 speed 1,5HPfor...
United Kingdom, Hull
...Product Features: • Toroidal design. • Supplied with 24" insulated secondary leads, terminated with crimped ring connectors. • Suitable for use with bare (uninsulated) primary conductor in circuits up to 600 V (4 KV Hi pot); or at higher voltage when a suitably insulated conductor is used. • All units have 5 A secondary for use with standard AC ammeters with 5 A movements. • Two hole mounting bracket on all models. • UL E227616 volume #1 file number X0DW2...
France, Kedange-Sur-Canner
...{"COMPOSITION AND APPEARANCE":{"•":"Hardness °IRH: 40-90. Max Force Mpa 10. Max temp 6v°C: +100°C. Cold resistance: -55°C"},"TECHNICAL DEFINITION":{"•":"Quick and easy installation, secured with metal fixing brackets"},"DOCUMENTS TO CONSULT":"Compliant with NF - EN 13829 standard for BBC sites (RT 2012).","TECHNICAL CHARACTERISTICS":{"•":"..."}}...
...Fire protection for joints tested according to European standard EN 13501-1 with a fire resistance class of EI 90. Rexpandit is a foam-expanding joint element designed for use in joints in timber construction, hybrid construction, and solid construction (concrete, aerated concrete, masonry). Rexpandit is elastic and compressible and is clamped into the joint during installation (without adhesive). The joint is immediately smoke-tight and sound-insulated. It forms an effective barrier against the passage of fire, heat, and smoke. Tested for joints with expansion and shear movements.
... to ensure test repeatability. 4500 W water-cooled xenon arc lamp Total exposure area of 2,188 cm 2 (339 in 2) TFT full color 12" touch screen control panel display of all test parameters Direct setting and control of Black Panel Temperature; uninsulated (BPT) or insulated (BST) Direct setting and control of relative humidity Direct setting and control of specimen chamber air temperature Display...
United Kingdom, Wells
...Colour TFT display - 4 adjustable cycles - wash and rinse temperatures displayed, drain pump, break tank and chemical pumps fitted as standard - chemical dosing adjusted from control panel - heavy-duty wash pump - superior peristaltic detergent and rinse aid auto-dosing units - optional thermostop - insulated cabinet and door - double skinned boiler - extra usable wash height - low volume wash...
United Kingdom, Weston Coyney
... - Thermostatically controlled. - Bolt-in removeable ultrasonic transducer plate. - Bolt-in ultrasonic transducers ensure minimal downtime and extend tank life. - Multi-frequency ultrasonic transducers. All ultrasonics use sweep frequency technology. - Separate ultrasonic generator. - Industrial standard – continually rated. - Insulated frame. - Basket and lid inclusive. - Table top or bench inset mounted. - Operates from standard mains voltage. - CE Certified – UL approval also available. - Etc. ** Click for more **...
United Kingdom, Honiton
...Available with either 2 zip front door, or 1 zip front door with short rear zip, for all your Butt Fusion/Electrofusion requirements. Standard specifications: - 8oz cover material - 2 zip front door - Flame retardant (BS7837:1996) - Non-conductive with fibreglass frame - No loose components - Rubber feet for extended product life - Insulated and fully enclosed centre joint for operator finger protection - Waterproof - Guy lines & tent pegs - Storage carry bag - Assembly instructions...
Portugal, Faro
...Compact double-walled insulated cup with a swivel lid. The outer layer of the cup is made from recycled plastic. It fits under most coffee machines. The cup features a full-color wrap design molded to the product, making it durable and resilient. It complies with the EN12875-1 standard, and is dishwasher and microwave safe. The volume capacity is 250 ml. Mix and match colors to create your...
Germany, Köln
... 16 CF-F Voltage per pole:0.3 Current per pole:120 Bakeout temperature:400 Tightness:5 x 10 -11 Pressure (absolute):1 x 10 -10 mbar ... 2 bar Flange:stainless steel 304L / 1.4306 Conductor:OF-copper 2.0040 Insulator:aluminum oxide ceramic Al 2O 3 Weight:0.15 vacuum side:100 vacuum side:400 vacuum side:stainless steel 304/1.4301 atmospheric side:100 atmospheric side:not insulated atmospheric side:150 atmospheric side:silver-plated brass...
...In addition to our standard program, we also design and manufacture valves for extreme operating conditions. This includes pressure surge-resistant valves, as well as valves that can be used at temperatures up to 1200 degrees. There are various designs available for high-temperature valves. The housing can be either lined or insulated with ceramic wool. The metallic valve disc can be air-cooled...
Germany, Porta Westfalica
... an IP66 protection rating and an impact resistance of 7 Joules. An EMC version with coating is also available as an option. Technical Data: ---> Temperature Range min. temperature -40 °C max. temperature 60 °C ---> Seal Material: CR-(Chloroprene) ---> Protection Insulation: fully insulated according to VDE 0100 ---> Toxic Behavior: halogen-free ---> Surface Resistance Standard: IEC 60093...
Romania, Floresti
...It is an externally applied roller system with insulated aluminum slats, available in RAL colors and wood imitations, offered at the highest level of quality with manual operation, motor with switch, motor with remote control or crank. The Standard roller system can also be installed later after the carpentry has been installed, in this way the roller casing becomes part of the design of the building, and their color can be matched with that of the exterior of the building or the carpentry...
Germany, Bielefeld
...Whether single-walled, double-walled, heated, insulated, or a combination thereof, H.Behle GmbH stands by you as a reliable partner as a manufacturer. Of course, we take care of the entire planning process from sizing to thermal technology and agitator selection. In particular, document-intensive products such as pressure vessels for the chemical industry are part of our daily business. Our manufacturing capabilities allow for the following dimensions: • Components up to 10 tons • Vessels with a diameter of up to 3500 mm • Components up to 15 m in length.
...Place of Origin: China Type: Insulated Application: industry,construction,decorative etc. Conductor Material: Copper Conductor Type: Solid Insulation Material: PVC Stock: stock for standard dimension and weight Length: as required Cu (Min): 99.99% Alloy Or Not: Non-alloy Shape: Round Lead time:15-30days Price term: Ex-work,FOB,CIF,CNF etc. Payment term: T/T,L/C,etc. Port of shipment:Xiamen Cu(Min):99.99%...
Germany, Kahl
... products. "Made in Germany" ThermSys offers all common mineral-insulated (MI) jacket heating conductors with outer jacket diameters ranging from 0.5mm to 6.5mm, with standard jacket material made of stainless steel up to 700°C (e.g., 1.4301, 1.4306, 1.4404, 1.4541, 1.4571) or with nickel-based alloy 2.4816 (Inconel 600) up to 1000°C jacket temperature. Special jacket materials such as 1.4845, Inconel 625, Inconel 800, and others can be manufactured upon special request.
Türkiye, Ankara
...The steel pipes used in the manufacturing of pre-insulated pipes are manufactured longitudinally welded (ERW) or spirally welded (SAW) in accordance with the norms required by the standard TS EN 253 or customer demands. Pipes comprise three basic materials. Carrier pipes are established as steel, copper or plastic based according to the properties of the carried fluids. Casing pipes are...
Germany, Lüdenscheid
... painted in other RAL colors. Full visibility can be optionally guaranteed at any installation site through large-scale glazing. The standard triple DURATEC glazing is scratch-resistant and thermally separated. Counterweights in the side sections ensure a quiet door operation and are particularly low-wear.
...0.6/1 kV copper conductor, XLPE insulated, halogen-free filled, galvanized steel wire, halogen-free sheathed multi-core energy cables. PRODUCT STANDARD BS 6724 / IEC 60502-1 ELECTRICAL PROPERTIES Rated Voltage 0.6/1 kV Test Voltage 3500 V DC PHYSICAL PROPERTIES Operating Temperature 90 °C Short Circuit Temperature 250 °C Minimum Bending Radius 6D for 1.5 - 16mm² 8D for 25 mm² and above...
France, Auxerre
... standard gray versions and blue versions for intrinsic safety. We also offer halogen-free instrumentation cables that are fire-resistant and non-propagating of fire. Technical details: -NF M 87 202 -Halogen-free -Mechanical protection -Fire-resistant -Good fire behavior -Significant stock...
Georgia, Tbilisi
...For fixed installation indoors, outdoors, in ground and in waterThe structure of conductor core is single-wire and conforms to 1or 2 class flexibility according to the standard IEC 60228:2004. On fillers of insulated sheaths a round copper wire (10-12) net and copper foil is wound, which performs protective and neutral cores function. The sections of conductor cores are: 1,5-10,0mm2 Number of...
France, Saint-Ouen-L'aumône
For over 35 years, 3P France has been the specialist in isothermal products and offers you solutions for short, medium, and long durations to address all your cold chain maintenance challenges. 3P France is committed to providing the cold chain maintenance solution best suited to your needs: - PE isothermal bags - Kraft frozen bags - Coolers - Isothermal covers - Refrigerant gels The isothermal ...
Ukraine, Radiviliv
... roof. It consists of 100 mm stone wool (solid type – 135 kg per 1 m³) and 50 mm standard stone wool; • 180 mm insulated floors, made of 180 mm polystyrene; • Underfloor heating (not infrared heating), controlled by a combined Buderus Logamax Plus GB-172-24K gas heating system; • Triple-glazed windows and doors from VEKA; • The exterior cladding is made of high-quality PVC panels from Kerrafront...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play