...research, development...), these sensors are used due to their excellent measurement quality, high protection rating, and long service life. Application areas include: - Monitoring of slow and fast movements between machine parts - Position measurements and changes in position of components and foundations, servo controllers, valve controls, robot controls - Growth measurements The incremental...
Belgium, Jumet
... Compliant with EMC EN 500822 Reference:CONV-UI Weight:130 g Type (-):Signal converter Accuracy (% F.S.*):<= ± 0.2 % Bandwidth (Hz):0...1 Service temperature range (°C):-10...+60 Storage temperature range (°C):-30...+80 Power supply (-):20...270 VAC / 20...300 VDC Output tension (V):0...10 V (load resistance > 1 kohm) Output current (mA):0...20 mA, 4...20 mA (load resistance < 750 ohms) IP rating (-):IP20...
Switzerland, Rossens
...As a Signal Conditioner, the AN1500M is designed to process and display signals coming from various types of transducers (weight, load, pressure, torque, etc.) that use standard strain-gauge bridges. As a Load Monitor the AN1500M can also receive any signal within the ±150mVDC range coming from a shunt, a converter or any type of transmitter. The Load Monitor provides selectable input...
Switzerland, Winterthur
...In the high-precision level sensors of the 36XW series, the temperature dependence and nonlinearity are precisely compensated for in the microcontroller by means of a mathematical model. In addition to the RS485 interface, the measurement results can also be output via the integrated D/A converter as a rangeable analog signal. Extended lightning protection is also available as an option. Pressure Ranges:0…0,3 to 0…30 bar Accuracy:±0,05 %FS Total Error Band:±0,1 %FS @ 0…50 °C Interfaces:RS485, 4…20 mA, 0…10 V Special characteristics:Optimum accuracy...
...The measurement data acquisition module µCAN.1.ai-SNAP acquires analogue measurement signals and links them to the digital CAN world. Voltage +/- 10 V:Current 0(4)…20 mA Accuracy 0.01% (FS):Resolution 16-bit (1 mV / 1 µA) Sampling rate 20 ms / 50 Hz:Signal type freely configurable Fieldbus CAN:Protocol CANopen / Raw CAN...
Germany, Thierstein
...The LMP 308i is designed for continuous fill level and level measurement of water and liquid mediums. The signal processing of sensor signal is done by digital electronics with 16-bit analog digital converter. Consequently it is possible to conduct an active compensation of sensor intrinsic deviations from normal condions like nonlinearity and thermal error. In order to facilitate stock...
Germany, Gschwend
...) Frequency output 10kHz ±5kHz large input voltage range (10-28,8V) strain gauge technology robust design for use in field applications IP67 easy installation accurate results (0.2% accuracy) The torque sensor DRVZ provides a precise measurement of torque and angle of rotation when testing systems that are driven by PTO shafts, such as a tractor gearbox. Supply voltage:10 - 28,8 V DC Power consumption Ub 12 V:approx. 180 mA (Switch converter 2,2 W)...
...USB temperature converter - including free readout software - efficient and flexible measurement without additional measuring system - mobile and directly on site - for all common thermocouples.USB stick with software for direct reading and further processing on the PC Plug connection - flexibly connect the USB stick to the temperature sensor Processing of the measured values, transfer to the...
Germany, Duisburg
...ASME Section III, RCC-M) — Qualified according to IEEE Std 323, IEEE Std 344, and RCC-E — The separate measurement converter can be installed up to 400m from the probe Measurement range: 0.6…40 m / 2…131 ft Process temperatures: -50…+150°C / -58…+302°F Pressure: -1...100 barg / -14.5...1450 psig...
...Complete system for continuous measurement of specific conductivity in drinking water, process water, and swimming pool water. Ready to use on a stainless steel mounting plate: Measurement converter AMI Solicon4 in a robust aluminum housing (IP 66). • 4-electrode conductivity sensor Swansensor Shurecon P with integrated Pt1000 temperature probe. Flow cell M-Flow PG with manual needle valve and...
Germany, Donaueschingen
...adjustable range: -31000 to +31000 Accuracy:depends on input, see data sheet Output:2 alarm relays SPST, max. load 3 A / 250 V AC and 3A / 30 V DC; Optional: Analogue 0 or 4...20 mA ou Measuring rate:(15 s for the 0…50 mV, 4…20 mA, 0…5 V and 0…10 V input types) A/D converter resolution:128000 levels, display: 62000 levels Power supply:100...240 V AC ± 10%, 50…60 Hz Display:1-row, 5-digit LED...
...Simple design to facilitate connection to a PLC. 3. Operating functions by 4 set buttons. 4. I/O points (1 input, 2 outputs) as standard. Flexible Operation with Stable Performance 1. Optional analog output (0-5V initial). 2. Powers up to 8units of load cells with 6 wires connection, provide long distance compensation. 3. Selectable A/D Converter 30/60/120/240/480/960times/sec. 4. 1,000,000 weight resolution ability, with second generation Vibration Cancellation Filter. 5. Support theoretical calibration with loadcell sensitivity.
...Galvanically isolated, highly dynamic measurement system In the 200 kHz SIRIUS data acquisition modules, the analog measurement data in each channel is captured by its own dual A/D converter (2x24 bit resolution) with a dynamic range of up to 160dB. DEWESoft's modular system is suitable for any signal and any sensor and can be scaled from 4 to 1,000 channels without limitation. Galvanic...
...Measurement Software Measurement Data Acquisition Measurement Data Evaluation Machine Measurement Technology Measurement Automation Display Device Measurement Converter Measurement Instrument Interface Dynamic Measurement Static Measurement automated Measurement Station inline Control...
...CNC machines from isel are highly customizable systems that adapt to the specific requirements of your production. This primarily enables powerful machine accessories such as components for machine configuration, operation and monitoring, measurement technology, as well as efficient extraction systems. Our experts are happy to provide you with comprehensive advice before you purchase CNC...
Germany, Wimsheim
...Independent measurement system for measuring the surface speed of rollers on roller test benches. Precise measurement of vehicle speed for correlation measurements on the roller test bench. Easy setup on the roller. Spring force compensation for vibrations and surface irregularities. Integrated encoder with TTL pulse output. For analog signal conversion, a programmable F/V converter SmartTach can be offered.
Germany, Neumünster
...Electro-hydraulic installation tool for automated fixed or manual processing of blind rivets and nuts. — DMSD 2G control system Stroke measurement system with a resolution of 0.01 mm Force measurement via sensors through hydraulic pressure — Hydraulic connection for the pressure converter — Mechanical connection — Tolerance compensation Position offset 1.5 mm Angle offset 8° — Electric motor...
Germany, Weidenbach
...What you can expect from APROVIS SCR catalytic converters: - SCR housing with insulation - Optimised design of the catalytic converter honeycombs - Injection section with static mixers - Daily service tank - Dosing station for exact dosing of the reducing agent - Continuous measurement of nitrogen oxides (NOx) - Controlled urea injection at measured NOx values - High conversion rate and long service life...
Germany, Hamburg
...The PR 6221 series load cells have been specifically designed for use in truck scales. Exceptional precision and long product lifespan reduce service and calibration costs, helping to minimize downtime. When combined with the Connexx® converter, the PR 6221 sensor becomes a digital solution. - Exceptional reliability thanks to German quality - Precise measurement results due to the special...
France, Chateaufort
...Small-sized membrane sensor. Total insulation by silicone oil cushion. Protection against polarity reversal and integrated lightning protection (except for model 1660). Total liquid tightness, robust and reliable construction. Very high measurement sensitivity (on the order of a millimeter). 4-20 mA converter integrated into the sensor or remote depending on the version. Electrical insulation...
Germany, Ettlingen
...The RMD radiometer is one of the latest developments from Opsytec Dr. Gröbel GmbH. This easy-to-use radiometer is based on more than 30 years of experience in all areas of irradiation and illuminance measurement. It features a wide dynamic range and extremely low noise. For this purpose, the sensor already contains a multi-stage amplification, an extremely precise analog-to-digital converter and...
Germany, Hilden
...Typically, a converter is used to transform the current into a lower measurement range that can be processed by a measuring device or another electronic device.
Germany, Sulzbach-Laufen
...Kiesewetter Measurement Technology "Measurement technology calibrated to meet the highest demands of the 21st century. The highest quality standards combined with optimal value for money are a matter of course for us!" As a reliable supplier of top-level products in the field of measurement technology and accessories, we have been operating as a traditional company since 1908, both nationally and internationally. In doing so, we continuously strive to expand our extensive product range and provide you with the best possible service.
...The MID measuring transducer with EX approval (Zone 1 and 2). Flow rate from 0.05 to 203500 l/min. Accurate measurement ±0.2 % of the measured value. With a 4-line display.
... Diagnostic device Model Number:Futai-2000AV Application:For pig pregnancy testing Certificate:CE Scanning Model:Mechanical Sector Scanning Frequency:2.5MHz, 3.5MHz, 5.0MHz Display Depth:≥190mm Display Mode:B, B+B, B+M, M Obstetric Measurement:Distance, Perimeter, Area, Volume, Obstetrics(GA measurement for pig) Battery Capacity:≥2200mAh Image Processing:Smoothing, Pseudo-color and Histogram Image...
Belgium, Welkenreadt
...The IFQ MONITOR is an easy to use and configure monitor and converter for Flow-Tronic flow sensors. It disposes of one RS485 digital serial communication port with specific protocols for RAVEN-EYE or BELUGA flow sensors and one 4-20 mA input for external level. The IFQ MONITOR is the easiest way to integrate an open channel flow sensor from Flow-Tronic to a local station. KEY FEATURES...
Netherlands, Nieuw-Vennep
...The versatile Cinergia GE/EL+ vAC/DC Regenerative Converter combines all Cinergia models in one unit. A 4 quadrant AC Grid Emulator and AC regenerative load combined with a bi-directional DC power supply and regenerative DC load. This makes the unit widely usable in many applications. Think of battery testing, battery characterisation, battery emulation, PV panel simulation and testing of solar...
Germany, Hückelhoven
...The Model 682C03 signal converter can be used to supply constant current-fed ICP®/IEPE accelerometers and connect them to 4 ... 20 mA signal circuits. The signal converter supplies an output current proportional to the RMS or peak value of the vibration acceleration, the vibration velocity or the vibration displacement (adjustable). For an individual offer, please contact us directly.
Germany, Steinenbronn
...The electro-pneumatic converter T6000 operates on the nozzle-baffle principle. This allows for very precise, nearly hysteresis-free pressure control in the range of 0 to 8 bar overpressure.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play