Italy, Fontanafredda
... frost formation. Probe cycles: the temperature of the core probe controls the cycle ensuring control and precision. Cooling capacity (Evap. -10°C / Cond. 45°C): 4452 W Condensation: air-cooled Refrigerant gas: R452A GWP: 2141 Climate class: 4 Power supply (Ph / Volts / Hz): 380-420/3N/50 Max electrical absorption cold cycles: 2576 W - 5.69 A Max electrical absorption hot cycles (optional humidity): 1240 W (1240 W) Chilling capacity (+90°C/+3°C): 45 kg Freezing capacity (+90°C/-18°C): 34 kg...
Italy, Bolzano
...OB1000 medical suction unit equipped with: autoclavable collection jar OB-J FA 1000 ml with overflow valve and protective filter inserted directly in the lid, autoclavable max 30 cycles recharging cable complete with cigarette lighter plug and 2-pole connector Nominal suction power: 850 mbar (85 kPa) ±10% Nominal suction flow: 25 LPM at free air speed ±10% Maximum operating time (free-cycle): 60...
Italy, Guarene
... button and emergency mushroom, at a fixed speed of 15 meters / minute - Pneumatic tail lifts and compressed air system up to the gate movement management valve. Total length (mm):935 Total width (mm):950 Maximum box width (mm):650 Minimum box width (mm):160 (on request 120 mm) Minimum box height (mm):75 Conveyor rollers width (mm):780 Conveyor roller diameter (mm):48 Feed speed (m/min):15 Installed power (kW):0.37 Maximum load (Kg):50...
Italy, Caraglio
... PLUS) Integrated aftercooler for cool air delivery (FIBRA PLUS) Unit ready to operate High quality air output (oil carry-over <1 PP) Compact design, extremely manoeuvrable Easy to transport, lift and load Outstanding accessibility for maintenance...
Italy, Faenza
...Towed and transported atomizer with a tank capacity from 200 to 2000L and an air unit of 470, equipped with a 450mm diameter turbine, 6 outlets, 18 nozzles, with the possibility of hydraulically adjusting the upper mouths.
Italy, Bedizzole
...The RW ax systems for industrial refrigeration of process fluids (water, water and glycol) are air-cooled: the only resource used is therefore electrical energy, a decisive advantage in contexts where water conservation is advisable (due to its cost or scarcity). The IP54 level protection for the machines (against dust and other agents) facilitates their installation in outdoor environments...
Italy, Magenta
... flow of hot air, up to 20 times lower than the initial flow, and are finally treated in a significantly smaller thermal oxidizer. The advantage of this process is to achieve a reduced and highly concentrated flow to send to the oxidation unit to reach the self-sustaining condition, which is the state in which the heat produced by the oxidation of VOCs is sufficient to maintain combustion without the need for supporting fuel, significantly reducing the operating costs of the plant.
...MITA offers various configurations of industrial chillers, either air-cooled or water-cooled: all equipped with an electronic microprocessor for setting and displaying liquid temperatures at the outlet, and all suitable for Industry 4.0. Some advantages of industrial cooling units: - Autonomous air-cooled unit. - Maximum reliability and efficiency confirmed by rigorous internal testing. - Customizations and flexibility allowing for up to 80% energy savings in versions with free cooling systems.
...Aerobic type plants. Total Oxidation Activated Sludge Reactor. Moving Bed Biofilm Reactor. Combined Reactor. Membrane Bio Reactors. Water and Air Mixing. Dissolved Air Flotation unit.
...This unit was designed and built for protection of workstations mobile or permanent on the battlefield or in defense of sen- sitive targets, air-transportable as it is of limited weight and size. Aimed at the protection of operators armed. Front tilted 30 degrees with 8 mm x 70 mm slots suitable for hooking the side panels. Side panels dimensions 1000 x 1000 mm base 900 mm hypotenuse...
Italy, Pocenia
...The air handling unit (AHU) is a small piece of equipment for the simple treatment of air in small environments. It is usually composed of a single chilled water and hot water heat exchange coil, both for cooling and heating, or of a direct expansion coil in which the refrigerant gas circulates. Evaporation takes place in the coil itself within the rooms of use by an air filter and a low head...
Italy, Goito
... exposed rebar (by sandblasting or using abrasive brushes). Pour about 2/3 of the mixing water into the mixer, add Grout 6 SFR and the remaining water; continue mixing until a homogeneous, lump-free mixture is achieved. The mixing water should be about 13%-15% by weight (3.5-4.5 litres per bag). Use casting procedures that ensure the absence of discontinuities and avoid the formation of air pockets. For high anchoring sections, it is advisable to add Ghiaietto 6.10 (please refer to the appropriate technical data sheet for more information). Packaging: 25 kg bag Unit of Measure: €/kg...
Italy, Fidenza
...N ° 1 drilling rig, Ellettari brand, Ek 200 P model with separate control unit. Year of construction: 1999 Recently revised Power unit on wheels Diesel engine with 60 hp power Drilling unit with modular Mast rubber tracks for booms 1 m or 1.5 m long maximum pull 2000 kg Rotation head with maximum torque 700 kgm. 5 speeds Floating shaft with internal passage 40 mm Air / water / mud adduction head Excellent movements Immediately available Visible at our office Price upon request Year:1999 Condition:Refurbished Stock number:PX21943 Guy:drilling rig...
Italy, Grugliasco
... the stem: 4 - 13 mm Wheel width: 150 / 200 mm Working wheel dimensions: 610 x 150 x 304.8 mm Working wheel speed: 20 - 45 m/sec Guide wheel dimensions: 350 x 150 x 127 mm Cycle time: 400 pcs/h Power supply: 400V 50Hz 3Ph V/Hz Air: 5 - 6 bar Dimensions (height 2000 mm): 2400 x 1600 mm Machine weight: 8500 kg...
Italy, Colli Al Metauro
... technology ensures high accuracy; minimum noise production; reduced power and air consumption; reduced maintenance. Cuts per minute:30 Pulling Speed:115 m/min (380 ft/min) Pulling Speed (Brushless):160 m/min (530 ft/min) Average power consumption:3 kWh...
...Our outdoor air conditioner cover protects the external unit of the air conditioner from atmospheric agents, pigeons and wasps nests.
Italy, Bassano Del Grappa (vi)
...InRack Cooler HD is the ideal solution for cooling rack cabinets with 19" mounts, where precise control of the internal temperature and 24-hour operation are required. It features a split design with an external condensing unit using R410A refrigerant, with a range from 3.6 to 7.3 kW. InRack Cooler High Density is controlled by dedicated software, allowing for LAN connectivity of up to 16 units and interfacing with an automatic door opening system in case of an alarm.
Italy, Cervasca
...The Win Cooler is an evaporative cooler capable of reducing temperatures in small rooms, finding applications in various fields. It is an eco-friendly and low-cost solution, operating on the principle of evaporation: warm air passes through the wet evaporative panels inside the unit and is released back into the environment cooled down. The practicality of the Win Cooler lies in the fact that it is installed outside, thus avoiding clutter in small spaces. It can also be applied in civil contexts.
Italy, Fraz. Mollaro-Predaia
... flows can be achieved, up to a maximum of 48,000 m³/h. The filters in the Electrostatic Line, model AR, are designed with a robust structure made of bent sheet metal, suitable for floor installation. The units are equipped with an inlet flange for coupling with a fitting to connect to the system's ductwork. The filter also includes an electrical control panel for managing the electrostatic part and, in the case of models with a fan, also the start/stop controls for the suction unit.
Italy, Turin
...Introduced for the first time to the market in 2008, the Recube unit is now the flagship of Rimor's production. Recube is a compact ventilation unit capable of achieving excellent performance in limited spaces. It can be mounted on coating, rotogravure, flexography, and laminating machines, and allows integration with energy recovery systems, insulation systems, solvent control, flow rates, and pressure.
Italy, Civita Castellana
...The machinery is equipped with a COMPRESSED AIR TANK with solenoid valves for filter cleaning. There is a FAN FOR DUST EXTRACTION, a VENTILATION CHIMNEY, and a VENTILATION BASE. The filter consists of a metal box divided into two sections: one for the intake of dusty air and the other for the discharge of clean air. Both the intake of the air to be purified and the outlet of the purified air are located at the top.
Italy, Valgreghentino
... equipped with 6 rolls with insert in tungsten carbide, an air-blower and a tank for collection of the scales. The lubricant dispenser Mod. DL14 has two cochleas, one vertical and one horizontal. The cold rolling cassettes Mod. CRC150-30-33 are strong-built and do not require an axial regulation of every single roll because the very close tolerances of every single components of the cassettes guarantee the auto-alignment. The vertical bullblock Mod. MV14 can work with one or two passes. The double pass is necessary to obtain the diameter 4.00 mm.
Italy, Cherasco
...Army containers are suitable for air, land and sea transport available in both ISO 8’6” and 8′ with side doors and/or end doors painted in different colour shades and finishing (i.e. antiinfrared) 40ft, 20ft, Bicon, Tricon and Quadcon configurations (Italian production – TAA compliant) It is possible to provide customized unit on demand.
Italy, Sasso Marconi
... water condensing unit such as evaporative W-tech condensers over air condensers is simple: - Consistent performance throughout the year due to lower condensing temperatures - Higher thermal efficiency during winter/summer months - Optimum efficiency thanks to the use of recirculating water in fall with countercurrent air - Lower power consumption compared to an air unit...
Italy, Pernumia
... parts covered by the leaf wall: crucial for avoiding surprises from diseases and pests. As a professional product, it comes standard with an electric control unit featuring pressure adjustment and a main switch with calibrated returns and cabin control, ensuring safe operation.
Italy, Roma
... culture, thanks to precise temperature control, appropriate humidity, and CO2 concentration. With the most advanced controller – SMART PRO, the CO2 incubators offer an intuitive menu and user-friendly software. The ILC 180 incubators fully protect the tested load, allowing for hot air sterilization up to 180°C, ensuring that each new test begins in a clean unit. The absence of a fan further eliminates the potential for sample contamination.
Italy, Sissa Trecasali
... stroke of the hydraulic cylinder is 500mm, while the gap between the two working tables is 600mm. The MST electro-hydraulic press is equipped with a hydraulic power unit with monitored Rexroth solenoid valves. Other standard features include the following: – Siemens CPU for setting dimensions – Cylinder adjustment with limit sensors – Automatic movement controls using dual buttons – Air/oil heat exchanger – Pressure switch – Rear protective metal mesh.
Italy, Milano
... method to reduce the effects of moisture damage (a single unit can dry very large areas). - Does not require supplementary heat to operate. - Integrated heater regulators ensure peak performance throughout the year and help minimize operating costs. - Can be placed in indoor or outdoor environments. - Air can be directed to specific areas using flexible ducting. - Temperature control accessories are...
... cones (one per lane). After the picking phase, a pneumatically controlled mechanical system deposits the paper cones onto their respective lanes on the conveyor, located beneath the machine. The complete cycle time for inserting the paper cone is 2.5 seconds. Compressed air supply at 5 atm.
Matching products
ASM 216
ASM 216
Other products
EM208-4500
EM208-4500

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play