... thicknesses and widths and up to twelve acquisition channels • Replaceable NiMH battery on-site and rechargeable from a port or USB socket to be 'always ready'. • On/Off control via push button, clock, or temperature for greater user control. Temperature range: -100 °C to 1370 °C Number of channels: 6 or 12 Memory: 50,000 entries per channel Accuracy: ±0.5 °C Resolution: 0.1 °C Thermocouples: Type K Battery: Rechargeable NiMH Data collection start: Start and stop buttons or triggered by time or temperature...
Germany, Köln
... configured for a dual sensor. The rate sampling mode allows a shuttered sensor to extend sensor life in high rate processes. Rate displays of 0.1Å/s or 0.01Å/s are user selectable. In addition, Frequency or Mass displays can be selected. Four relay outputs allow the SQM-160 to control source or sensor shutters, signal time and thickness setpoints, and signal crystal failure. Digital inputs allow external...
Germany, Villingen-Schwenningen
... sensor can be accessed. Easy commissioning and data evaluation. The advantages of the DS 500 at a glance: — Clear: 7" color display with touch panel — Versatile: Up to 12 arbitrary sensors can be connected — Industrial-grade: Metal housing IP 65 or control cabinet installation — Globally available: Network-capable and remote data transmission via web server — Daily, weekly, and monthly evaluations — Mathematical function for internal calculations — Totalizer function for analog signals — Saves time and costs during installation — Mathematical function for internal calculations...
... in the video image. - Data recording: - Configurable status line with date, time, and meter value. - Save and retrieve from 64... Item number: 5-0037-001 Power supply: 12 - 24 V DC via external power supply (100 - 240 V AC) Type: Control unit...
... integrated hydrogen sensor to monitor ammonia dissociation quality in real time. A large custom designed operator interface provides easy access to review generator operation and the integrated paperless chart recorder tracks generator performance to meet production and quality auditing requirements.
...hydraulic unit, vacuum pump, time-volume recorder Kienzle, temperature recorder, relay control, retrofitted Siemens Micromaster 440 frequency converter, coding of ampoule base 2-line and closure 1-line, cutting waste separation, suitable for the exclusive processing of low-density polyethylene (PE), drive 400V/50Hz/17kW, filled with saline solution (NaCl), installation, commissioning, and training by technicians from the previous operator possible worldwide.
Germany, Dresden
... Sequencer: Maximum Events: Unlimited (Dependent on CPU) Resolution: 960 Parts per ¼ Note (ppq) Sequences: 128 Tracks per Sequence: 128 Drum Pads: 16 (Velocity and Pressure Sensitive) Drum Pad Banks: 8 Synchronization: MIDI Clock, MIDI Time Code Transport: MIDI Machine Control Effects: Program Effects: 4 Insert Slots per Pad, 4 Sends per Track Effects per Pad Track Effects: 4 Inserts and 4 Stereo...
...The remote sensor heads and any alarm or recording devices connect to terminals on the front of the module. Each Statox 501 control module has three relays for alarm 1 and 2 and system failure (115 / 230 V AC / 2 A). An analog output for recorder or process control systems is also included. Measured values are displayed on a 4 digit LED-display. It is easy to program or calibrate the Statox 501...
Germany, Heidelberg
... video support - Status notifications and alerts via email - View and evaluate the time course of measurement values for all pools on the integrated chart recorder - Simple, unlimited connection via LAN – just like in your home network...
Germany, Berlin
...-analysis of current and voltage harmonics up to the 51st for class I (according to EN 61000-4-7). -configurable archives of actual values and event recording. -data archiving on an SD card - memory up to 32 GB. -web server, FTP server. -interfaces: RS-485 Modbus slave, Ethernet 100 Base-T (Modbus TCP server), USB device & Host. -colour touch screen: LCD TFT 5.6”, 640 x 480 pixels. -IP65 protection grade from the frontal side. -synchronization of RTC clock with the NTP time server.
... use: For analog and digital sensors Embedded, Linux, LabVIEW, real-time: System construction, certifications, analyses, evaluations Calibrates sensors: with data logger With integrated chart recorder: evaluation system Parameterization of all sensors: calibrates infrared sensors Calibrates analog sensors: calibrates transmitter sensors...
Matching products
Sentax
Sentax
Other products
Thermostick
Thermostick
... completion, 16-bit analog/digital converters, and an option for ICP accelerometers. With the latest development, SWIFT presents the MAS-MICRO-III-X system in the third MICRO generation, a forward-looking, powerful, directly recording, and autonomous data acquisition system in 4 to 40-channel versions. The recorder offers enormous reserves of computing power for executing complex algorithms, such...
Popular countries for this search term

The europages app is here!