Germany, Aue
43km
...Cooling water systems consist of all components necessary to direct heated cooling water to the cooling system and transport the cooled cooling water to the consumer (heat source). This includes, among other things, water treatment technology as well as the cooling system along with dry coolers, chillers, and cooling towers. We offer systems for industrial use across all common industries. Our factory production under optimal conditions, including factory testing, guarantees optimal quality.
Germany, Immenhausen
199km
...BLUELINE HT: Cooling water for laser systems, welding technology, and generally systems with localized high thermal loads. Capacity of a filter cartridge approx. 400 liters of deionized water *) according to VDI 2035 BLUELINE HT: Simple and safe filling and refilling of cooling water systems No specialized knowledge required Produces deionized water according to VDI 2035 with...
Germany, Seligenstadt
213km
...Water cooling unit for use with the EVO 200 WP or LITE control systems or Tetrix 200 in conjunction with water-cooled welding tools. — Stand-alone or continuous operation possible — Temperature-controlled fan operation — Feedback on water flow via built-in flow meter Scope of delivery: — Water cooling unit — Connection cable inverter / cooling unit (permanently installed) — Clamping closures...
...Construction, Installation, Commissioning: When the cooling water systems reach a certain size or capacity, IKS provides modular, prefabricated components. The final assembly of the elements takes place on-site. Piping and electrical installation are carried out at the construction site. Your benefit: short assembly times due to precise planning and predefined installation situations. Design, construction, and service from a single source. Do you have questions about project planning, services, and conditions? We will promptly send you your individual offer.
Germany, Grünhain-Beierfeld
51km
...Application Areas at the Customer Installation in osmosis systems, cooling towers, ultrapure water treatment, irrigation systems, greenhouses, wastewater treatment Features of Our Valves High flow capacity Suitable for contaminated media Low closing stroke Free of non-ferrous metals...
Germany, Berlin
227km
...Corrosion and scaling inhibitor as well as dispersing agent for open cooling circuits and air washers POLYDOSIL AK is a mixture of cationic polyelectrolytes (free from zinc and chromate). The product is used for conditioning make-up water for cooling systems with high carbonate hardness. The polyelectrolytes enhance this effect and also act as a dispersing agent. Due to its excellent cleaning properties, the product can also be used for the operational cleaning of cooling water systems. Weight: 30, 60, 210, or 1,000 kg...
Germany, Burgtonna
108km
...In almost every large industrial hall, there are supply air systems that bring cool air into the halls to make the climate bearable. In this area, IMH has been active for 20 years and has included cooling water piping in almost every piping project for a paint shop. These pipes extend from Germany across Europe to Asia, where IMH has successfully completed many projects to the satisfaction of...
Germany, Oberndorf
232km
...Used for water treatment of cooling systems (cooling towers). This system includes an antiscalant dosing, and during downtime, automatic preservation occurs. Product/Application: Drinking water treatment using reverse osmosis Solid content supply: Limited water analysis Total capacity: UO 10,000 l/h Total filter area: approx. 450 m²...
...["— Save up to 1.8% on fuel costs through higher utilization of exhaust heat","— Easy retrofitting for older systems due to low space requirements and simple piping","— Coordinated control for safe operation of boilers and components","— Quick payback even for systems with few operating hours","— Ready for operation with just a few connections","— Simple commissioning, operation, and maintenance"]...
Germany, Nordhausen
132km
... trapezoidal forms. Mobility requires reliable cooling and heating systems. These help both people and machines – whether electric or combustion engines – adapt to varying environmental conditions on land, water, and in the air. Climate systems and all their components must endure high load cycles over time. Instead of testing durability in real operation, manufacturers can now flexibly and economically...
Germany, Rain
229km
...Energy systems for industrial plants can sometimes be expensive to maintain. This is why we already pay attention to economic solutions during the planning and conception of your plant. Our heating and cooling systems are needs-based, individual solutions for seasonal and user-related requirements. Heat transfer media such as water, air or oils are heated by means of large-capacity water boilers...
Germany, Berlin
238km
... temperature: 0 to 50 °C, with water cooling up to 180 °C Field of view: 90° Measurement points per line: Up to 1024 Line frequency: Up to 150 Hz Power supply: 24 VDC ± 25 %, 1 A Ethernet communication: TCP/IP (10/100 Mbit/s) Serial communication: RS485 Analog outputs: 3 x 4 – 20 mA Alarm output: Relay, contacts: 30 V, 1 A...
Germany, Hildesheim
225km
...The dry cooler from N-thalpie GmbH is used in refrigeration and air conditioning systems to dissipate the thermal energy from process fluids (e.g., coolants or refrigerants). Unlike water-cooled systems that use water as a cooling medium, dry coolers use air as the cooling medium.
Germany, Butzbach
242km
... arrangement. Entrained particles from the dry zone are removed in the wet zone. Moisture levels of less than 1 % can be achieved. The residence time of the product is typically between 5 and 15 minutes. The outstanding heat transfer rate for hot solid products enables cooling of large amounts of solids in a compact machine compared to usually used cooling screws and without cooling air.In product...
Germany, Niederwinkling
197km
... reduces machining costs. Castrol Alusol ABF 10 is suitable for both central systems and individual systems. Application Castrol Alusol ABF 10 was specially developed for processing aluminum alloys. The product can also be used to process low-alloy steels and non-ferrous metals . Product number:1721303 Container size:208 Product group:not water-mixable coolant...
...THE RIGHT COOLING SYSTEM MATTERS! We assist you in finding the right cooling solution - Gathering technical data - Calculating the required parameters - Selecting the most suitable cooling concept - Choosing the necessary equipment with the appropriate capacity - Adjusting the system to the profile...
... connection DN50 Steam line connection (cooler) DN100 for flanges according to DIN EN 1092-1 Form B Positioner Digital positioner type 8049 Positioner with integrated process controller type 8049 IPC Positioner type 8049 also available in explosion-proof version Mounting of the positioner according to NAMUR standard Size::DN 50 Pressure::PN 40 - Huge control range thanks to a system of 4 nozzles. Material::Stainless steel 1.4571 / 1.4408 Temperature::-60 °C to +220 °C Application::Water injection for steam cooling...
Germany, Ronneburg
28km
...Water with fewer biofilms and legionella Electrolytic disinfection Smartpure Permanently stagnant rainwater in tanks or circulating water in climate, humidification, or open cooling systems are heavily contaminated with germs. Facilitated by a warm climate in the surroundings or in the pipes, biofilms and legionella form. In addition to the intensive use of biocides, health hazards are...
... groundwater - cleaning of cooling circuits as partial flow cleaning or as cleaning of the entire volume - protective filters for downstream systems in case of disturbances - removal of hydrocarbons, oils, or organic components using activated carbon filters.
Germany, Gornau/erzgebirge
69km
... drinking water but also of utility water and process water in industrial applications. Typical applications include: • Disinfection of drinking water, e.g., in residential and hotel facilities • Treatment of process water in the industry, e.g., in the beverage sector (CIP systems) or washing systems • Disinfection of water in humidifiers, air conditioning systems, or cooling systems • Germ reduction in cooling water circuits, e.g., in open cooling towers, cooling plants, or air conditioning systems • Sustainable disinfection of swimming pool water • Wastewater treatment in...
...We deliver and install complete cooling and chilled water systems, including the necessary machine cooling technology, heat exchangers, buffer storage, pumps, steel construction, fittings, control and regulation technology, and insulation. The required planning, commissioning, and maintenance services complete our offering. Complete distribution systems for: • Ammonia pipelines • Solar pipelines...
Germany, Linsengericht
210km
... to ensure test repeatability. 4500 W water-cooled xenon arc lamp Total exposure area of 2,188 cm 2 (339 in 2) TFT full color 12" touch screen control panel display of all test parameters Direct setting and control of Black Panel Temperature; uninsulated (BPT) or insulated (BST) Direct setting and control of relative humidity Direct setting and control of specimen chamber air temperature Display...
...High-efficiency heat recovery system for heating and cooling. EcoCond is a high-performance circuit connection system. Essentially, the system consists of a counterflow air-water heat exchanger in the supply and exhaust air unit, a circulation pump, hydraulic connections, and an integrated control system. Thanks to the economical operation of the system, the life-cycle costs of air conditioning systems can be sustainably reduced.
Germany, Niederstetten
204km
...With our HPT heat pump test bench you can simulate humidity as well as temperature. The test stand is used for functional testing of air-to-water heat pumps according to DIN EN 14511. Current test systems on the market, which are used to test e.g. air-to-water heat pumps, are climatic chambers with a cooling, heating and humidification unit fixed to the roof. The disadvantage of this concept...
...The Split System WP HEATER BLN-TAS Series 012...018TAS consists of an indoor and an outdoor unit, and is best protected against freezing. Split inverter heat pump for heating, cooling, and hot water preparation in a power range of 4.3 to 20.5 kW. It features a separate outdoor unit and a hydronic box inside the building. Energy label A++ DC inverter compressor with EVI and regulated fan...
...The operator wants to limit the amount of refrigerant even in compound cooling systems (e.g., hotels). 3. There are consumers where heat exchangers are installed that need to be cooled with cold water, such as mainframe computers, radiological specialty devices like magnetic resonance or computed tomography scanners, or machine tools in industrial use. Chilled water systems are available from under 10 kW cooling capacity to the megawatt range.
Germany, Stadtallendorf
215km
...Advantages The multiple options enable us to fulfill special customer requests in a flexible way. FAUDI Belt Filters have the ability to be installed on existing vessels or can be delivered as complete systems with vessels, pumps, heating, cooling and control systems. Furthermore, the system enables an increased flow rate. Area of application For the continuous cleaning of coolants, especially...
Germany, Mühlheim
236km
...The flow monitor reliably protects your device or system from failure. It monitors, for example, coolant, lubricant, or water circuits. These are often used in coolant systems, air conditioning units, lubrication systems, machines, welding heads, laser heads, presses, conveyor belts... There are various ways to monitor flow. Our flow monitor is much more affordable compared to other electronic...
... chamber. In addition to temperature treatment, height differences of up to 5 meters can be overcome simultaneously. Technical Data: —Chain width: up to 1400 mm —Usable chain length: up to 1000 m —Temperature range: +1°C to +85°C —Insulation hood with access doors and viewing windows according to customer specifications —Cooling system with direct evaporation or flow cooler with refrigerant (e.g., brine) —Heat exchanger with hot water or steam connection...
Germany, Bad Königshofen
120km
... station, washing machine with salt recovery, chamber tempering furnace, and charging cart. The heat treatment goods are transported on special transport racks using the rail-guided charging cart, either via manual control or in automatic mode from station to station. Batches weighing up to 1200 kg can be heat treated. The salt quenching bath with air or water cooling is designed for both bainitic and martensitic hardening. Possible heat treatment processes: - Annealing - Tempering - Hardening - Quenching - Carburizing...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play