Germany, Karlsruhe
...The compact inverters of the SUN2000 series from Huawei are the all-in-one solution for PV systems with storage. Whether for off-grid operation, grid feeding, or zero feeding - everything is possible. The output power can be limited to 600VA. Thus, they represent a professional alternative to simple microinverters. With the higher maximum DC input power, the PV system can be expanded with...
Germany, Heiligenstadt I.ofr.
...-releasing terminal clamps (in higher current ranges on bolts or Cu rails) high-quality, tropical-grade vacuum impregnation in... Input voltage: max. 1000 V Connection group: Ii0 Output voltage: max. 1000 V Protection class: IP 00 Insulation class: B/F Ambient temperature: typically 40°C Frequency: 50-60 Hz Power range: 40 kVA - 400 kVA Output current at: - screw terminals max. 200 A - bolts max. 500 A - Cu rail max. 3000 A Protection classes: I...
Germany, Willich
...Silicone switch mats have always been one of our core competencies. We provide you with detailed advice on the equipment needs of your switch mat and assist you in selecting the right materials. We offer comprehensive guidance in choosing the appropriate materials and provide options for cost reduction. If desired, we can support you already in the design phase and accompany you through to...
Germany, Andernach
... MPPTs to maximize flexibility, it stands out as an extremely attractive option. Key Features: Higher yields: Two integrated MPPTs allow for the input of two arrays from different roof orientations. Safe & Reliable: Comprehensive protection features, including DC reverse polarity protection and AC short circuit protection. Smart: Enables remote monitoring and control of the system. User-friendly: Easy...
Germany, Villingen-Schwenningen
... side, the inductive voltage that occurs with inductive loads is internally limited. Input voltage: max. 500 (575) V AC Max. output current ADC: Single-phase: 0.7 - 2.0 A; Bridge: 0.7 - 2.0 A; Overexcitation: 1.4/0.7 - 3.0/1.5 A Overexcitation: depending on type 2:1 Rapid disconnection: external or internal with voltage or current detection Standards: CE, ROHS, IP 00, UL Accessories (optional): DIN rail clip, adhesive pad, mounting clip, wires for motor connection M4...
Germany, Seligenstadt
...) Power: 1000W / 4.5A Protection class: II Speed control: 6-step control Weight: 47 - 77kg Package includes: Tube saw with electric drive One saw blade One bottle of saw blade lubricating oil Size range in mm:OD 6 – 220mm Size range in inch:0.236 – 8.661 Wall thickness:1 – 8mm Electric drive:Single-phase AC motor Mains voltage (input):200/220VAC (50/60Hz) Power:1000W / 4.5A Protection class:II Speed control:6-step control Weight:47 - 77kg...
Germany, Singen
... display and single-knob operation (rotary control) is derived from the automotive industry and has proven itself worldwide in the "infotainment systems" of modern luxury vehicles. The... 165 CA: Connection voltage Wide-Range 90 - 260 V, 50/60 Hz, single-phase 300 CA: Connection voltage 400 - 480 V ± 10%, 50/60 Hz, three-phase 300 CA AC/DC: Connection voltage 400 V ± 15%, 50/60 Hz, three-phase 300 CA AVC/OSC: Connection voltage 400 - 480 V ± 10%, 50/60 Hz, three-phase...
...-phase primary switched • Stabilized output voltage • Short-circuit and overload proof • Wide input voltage range • Mounting on DIN rail according to EN 60715 Ready for shipment: in approx. 3-4 days Item No.: 42 20A 500...
Germany, Wilkau-Haßlau
...Electronic Reactive Power Controller BR 7000 Three-phase measurement and control Reactive power controller and network measuring device LCD full graphics 128 x 64 pixels Dimensions: 144 x 144 x 50 mm Inputs: Operating voltage: 110...440V~ 50/60Hz 3 x Measuring voltage: 30...440V~ (L-N) 50...690V~ (L-L) 3 x Measuring current: X:1A / X:5A 1 x external input Outputs: 3 x 5 relay switching outputs for capacitors 3 relay outputs for notifications, alarms, fans 2 interfaces RS485 - Modbus RTU (RJ45)...
...Input Voltage: 230V Output Voltage: 0 ...... 230V Single-phase step-down transformer with rotary knob and scale, maximum ambient temperature 40°C, insulation class E, protection class IP 00, suitable for installation up to IP 23, screw terminal connection, frequency 50-400 Hz. Ring transformers are used depending on the application for normal or demanding operation. If the current collector is not moved for an extended period (24h) or is frequently switched on or off under load, this constitutes demanding operation.
...according to EN 61558, with capacitor smoothing, insulation class T40E, complete resin impregnation, separate windings, with shielding winding, conditionally short-circuit proof due to secondary fuse (up to 10A - device with operating indicator light, protection class IP00, screw connection, terminals according to BGV A3, protection class 1, silicon rectifier in bridge configuration. Residual ripple 4%, 50/60 Hz Input voltage: 230 V / 400 V ± 15 V Output voltage: 24 V DC (no-load voltage approx.: 29 V)...
Germany, Bruchköbel
...Frequency inverter with high accuracy and excellent torque adjustment. It offers a three-phase input of 200-480V. The output voltages range from 200-480V for motor powers of 0.75-160kW. Technical Details: Constant torque / Variable torque for normal and heavy load operation U/f and U/f PG control, sensorless vector control, vector control with selectable sensor 150 MIPS high-speed DSP Outstanding...
Germany, Oestrich-Winkel
...The MDR series is a single-phase primary switched power supply designed for mounting on DIN rails or busbars of type TS-35/7.5 or TS-35/15. The power supply is used in enclosed distribution cabinets such as control cabinets or control systems. High energy efficiency and wide input range. The power supply can be operated with either alternating current or direct current. Highlights - Active DC...
Germany, Nanjing
...5 Wire AC system Nominal Input Voltage: 380V (+20% and -20%) Input Frequency: 50Hz, ±1.5Hz / 60Hz, ±1.5Hz Ambient Temperature: -25 to 55°C Ambient Humidity: 5 to 95% Storage Temperature: -40 to 70°C IP Ratings: IP 54 Cooling: Forced air cooled Number of Outputs: 1 OR 2 Type of Each Output: 250-750VDC (+20% and -20%) Output Current: Max. 150Amp Power Factor: ≥0.99 (50% load above) Display & Touch...
Germany, Gräfelfing
...The DFC locking electronics consisting of the Phase Frequency Detector (PFD) and FALC 110 provides high-end phase frequency locking for comb applications. The PFD RF input is designed for use with the RF output signal of the DFC MD. The error signal generated by the PFD is fed to the input of the FALC 110 regulator. The main output of the FALC is passed through the PFD to allow for remote...
Germany, Nürnberg
... motor Input signal: Terminal W of 24 V three-phase motor Output contact: Potential-free normally closed or normally open Maximum switching power: 40 W (0.2 A at 220 VAC) Operating temperature: -20...+70 °C Connection: DIN 46244 flat plug A6.3 x 0.8 Mounting: G-rail TS32 or DIN rail TS35...
...They are the equivalent of single-phase transformers, but designed for connection to three-phase networks. We naturally manufacture versions with safe galvanic isolation, as well as transformers in savings configuration according to EN61558-13. Input: according to customer specifications Output: according to customer specifications Connection group: according to customer specifications Power...
Germany, Dauchingen
...-step driver Supply voltages: 12...48 V DC, 5 V DC for logic Max. motor current per phase: 2.0 A Max. step frequency: 40 kHz Typical operating temperature: 0 ... +50 °C Limit values for heat sink temperature: 0 ... +70 °C Additional options and accessories (selection): Interface boards (INT-462, OSC-462H), heat sinks, connector strips INT-462 Description: Interface board for IB462He with screw terminals INT-462 Communication interfaces: Opto-coupled clock/direction input...
...Simple stirrer directly driven by a three-phase motor for high speeds. Standard version -Three-phase motor -Stirring shaft -Stirring element (propeller design) -Speed range from 750 rpm to 3000 rpm. Application area -Fast runner -low viscosity media -Water treatment -Paints and coatings / Automotive industry -Direct drive for dispersions with high power input -for IBC containers -for stands...
...By using a power contactor sized for the rated input current in combination with a second power contactor tailored to the pre-magnetization current, the ICL can be used like a main contactor (coil voltage 230VAC). Connections up to 95A are made via terminals; above that, directly at the main power contactor. Up to 10 switch-ons per hour are allowed. The ICL is optimized for vertical installation on a mounting plate.
... required. • Form factor F < 1.05, resulting in low motor heating and high torque reserves. • Overload capacity up to 200% peak current for a maximum of 1 second. • Stall protection with overload shutdown. Accessories: • Module carrier for 35mm mounting rail • Module carrier for screw fastening • Setpoint potentiometer 1 gang or 10 gang Dimensions: • PCB version: 160 × 100 × 40 mm (L × W × H) • Connection: 16-pole pluggable screw terminal block Armature voltage: 0-210V DC Description: 1Q GS1/xx-294 Input voltage: 230V AC Motor current: 2/4 A...
... solutions, blocking filters are designed for high, ideally linear insertion loss without significant level reduction at the input and output. EICHHOFF offers PLC filters for frequency ranges of 20-120 kHz, 50-500 kHz, and 1.8-68 MHz, available in 1-phase and 3-phase versions with rated currents up to 63 A.
Germany, Hohen Neuendorf Ot Bergfelde
... expansion module (RS232, BACNET, ETHERNET) Current input 1A or 5A – connection to external current transformers (transformer ratio (CT) adjustable) Voltage: 80…500V (Phase-Phase) – direct or with voltage transformer (transformer ratio (VT) adjustable) Auxiliary voltage: 80…265Vac/110…300Vdc or 11…60Vdc...
...Hot Runner System - Temperature Control Device DP1/DP2 The compact controllers for cost-effective and comfortable regulation of small hot runner systems Easy operation through separate displays and input buttons Total connection power single-phase, 230 VAC*, 16 Fuzzy-PID control behavior Soft start function for gentle ramp-up Actual temperature and level display for each zone...
Germany, Kirchzarten
... additional safety during the positioning phase (optional). Nominal torque / Nominal revolutions: 1 .. 10 Nm / 30 .. 0.25 rpm Analog setting of the nominal value: 0 .. 10 V, 0/4 .. 20 mA Stroke: max. 50 revolutions Body: Plastic with IP 55 Output shaft: Solid shaft of 12 mm Power supply: 24 VAC...
Germany, Regensburg
...{"IP Protection Class":"IP20","Warranty":"3 years (optional 5 years) without operating hour limitation (according to LEDAXO warranty conditions)","Color Rendering (CRI)":">82 Ra (optional 90 Ra)","Beam Angle":"15° | 24° | 40°","Input Voltage":"100-265 V AC","Features & Special Characteristics":{"-":"Available in 3 different beam angles"},"Mounting Type":"3-Phase Track","Weight":"1.90 kg...
Germany, Bonndorf
...Wide selection of blowers based on universal motors and brushless motors - The blowers are available in various sizes and optionally as Thru-flow or Bypass variants - All variants are available for both 3-phase AC or low-voltage DC supply - Optionally with integrated control electronics featuring speed input (AI or PWM) and fault output...
Germany, Friedberg
... % 50 / 60 Hz Electronics: Symmetrical phase-cut control with automatic soft start and current-dependent adjustment. Interference suppression: Complies with EN standards. Housing: Plastic housing Weight: 600 g Dimensions: 150 X 80 X 55 mm Fuse: Touch-protected fuse holder, 6.3 A super-fast.
Germany, Wiesbaden
...The DP6812 HUD is a visualization toolkit that enables customized input and extraction of image data on existing components. The product offers hardware expansion for head-up displays tailored to various vehicle models. The DP6812 HUD is used during the development phase in prototypes, test benches, technical carriers, and test vehicles or show cars. It allows for individual head-up display customization and installation of the DP6812 HUD even in production vehicles. The DP6812 HUD takes over the switching function between the original head-up display image and the custom image from the PC system.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play