Germany, Herrenberg
230km
...A special feature of the compact pressure switches is the adjustable hysteresis. In the standard version, the fixed contact distance in the pressure switch determines the hysteresis for the user. In the following series, the contact distance can be changed, allowing both the switching point and the reset point to be precisely adjusted. The HDC is designed for environmental conditions. It operates...
...Whether it's custom switching programs, personalized terminal labeling, or other extensive customizations. We offer a solution for every application – starting from a quantity of 1. Contact us for a switch tailored to your needs.
Germany, Porta Westfalica
206km
... oxide layers are rubbed away – the electrical contact is made reliably. — Door contact with contact plates or contact pins — Mechanical lifetime: more than 10 million switching cycles — Protection class IP20...
Germany, Heiligenstadt I.ofr.
106km
... and currents with separate windings Input voltage: max. 230 V Switching group: Ia0 Output voltage: max. 0 - 230 V Protection class: IP 00 Ambient temperature: max. 40°C Output current: max. 63 A Frequency: 50 - 400 Hz Power range: 184 VA - 14490 VA (higher power on request) Thermal class: 130 (B) Protection classes: II...
Germany, Obrigheim
150km
...The MINICOMB® is a pressure switch for measuring the pressure or vacuum of gaseous and liquid media, based on a force gauge measurement system with a bellows sensor that actuates a switching contact. The force gauge measurement system with bellows sensor is designed to be frictionless, providing high repeatability and excellent long-term stability. The MINICOMB® can be configured in measurement...
...-way comparator with switching outputs is available for classifications and selections. Of course, temperature compensation is available for any test object material. Specific temperature coefficients can be entered. Temperature recording takes place using a PT100 sensor or a temperature transmitter (pyrometer) with an analog output. A special circuit for protecting the measurement input when...
... an isolating washer. The resilient preloading disk ensures excellent performance. The resilient preloading disk keeps the contact pressure constant throughout the entire temperature range of the BEDIA switch until switching occurs. The mechanically and electrically unloaded bimetal disk snaps over at a preset temperature, with either opening or closing the contact arrangement. The bimetal will only snap back to its initial condition after the temperature has dropped significantly.
Germany, Lindlar
196km
...Format 48 x 96 mm, portrait Two/three step, continuous controller Sensor monitoring Up to 5 outputs 1 Analogue input (universal) 1 Binary input 1 Relay output (closing contact) Self-optimization (autotuning) for exact PID control Manual/automatic mode Configurable limit monitoring (alarms) Setpoint switching Level/keyboard locking RS485 interface (Modbus RTU) Ramp and timer function Firing curve for ceramic furnaces Plug-in controller module Setup interface (USB Mini-B)...
... operation - Self-supporting construction - No additional fastening required - Long service life Application area Short-circuit switches of type SCC with specially encapsulated contacts are used in all electrolysis processes. The encapsulated contacts ensure maintenance-free operation and a very low voltage drop. Pre-contact systems The main switch can be equipped with various pre-contacts. This increases the switching capacity of the switch. Ritter is the only manufacturer to offer a type-tested pre-contact with a switching capacity of up to 70 V DC at 45 kA.
Germany, Zell Unter Aichelberg
211km
...The ToolGrip SK tool clamping sets have been a proven series product for automatic tool changes for many years. They clamp steep cone tools with clamping bolts according to DIN 69871/72. The 6-piece clamping finger set provides optimal force distribution, allowing for higher permissible clamping forces. And this is achieved with faster switching cycles. On request, all clamping sets are also available in wear-resistant, coated versions. Contact us!
Germany, Bretten
189km
... • Rugged, wear-resistant workmanship • Numerous application options for coil gauges from 0.5 to 10 mm • Viscosities up to 150 mm2/sec possible Design versions and details In this field we offer three product lines with different roller diameters. 32 Series Our compact felt roller lubricators are designed for coil gauges up to 0.5 mm as well as viscosities up to 100 mm2/sec (recommended guideline values). Fields of application Contact components: tab connectors, electric switching contacts, contact springs Punched and bent parts: medical technology, microelectronics, precision engineering Fine bla...
...• Contactless voltage tester with flashlight • For AC • With voltage field sensor for non-contact detection of alternating currents with visual indicator (red LED), voltage range 90 - 1000 V, e.g. in cable connections, wall sockets, junction boxes, circuit breakers & fuses and many more • Integrated flashlight for measuring point illumination • Pushbutton for switching on, with self-test and...
Germany, Mülheim
242km
...Inductive sensors detect metallic objects without contact and wear. They utilize a high-frequency electromagnetic alternating field. The sensors' notable strengths include exceptional durability, high reliability, fast switching frequencies, and a long lifespan. Thanks to a unique coil concept, uprox® sensors additionally provide the greatest switching distance, a factor of 1 for all metals, and the highest operational safety from the start through simple and secure installation.
Germany, Karlsruhr
206km
... interface between (electrical) power supply / control and a pneumatic SITEMA clamping head. All pneumatic SITEMA clamping heads with an operating pressure of up to 4 bar and an operating volume of up to 220 cm³ can be pneumatically controlled by the EPM. It is also possible to operate several clamping heads in parallel with one EPM. The EPM is controlled by a 24V supply and switching voltage. The outlet pressure which is required to open or keep open a pneumatic clamping head is controlled by a control signal. If the voltage fails or the input signal is switched off, the pressure is...
Germany, Köln
223km
... … +8.5 Measuring range 3PIx-0xx-xxx2:+0.375 … +5.529 Measuring range 3PIx-0xx-xxx3:+1.57 … +8.875 3PIx-0xx-xxx0:1.286 Load impedance:>10 Range (N 2):5×10 -5 … 1000 Relay contact:n.o., potential free Hysteresis:10 Contact rating solid state relays:≤30 Contact rating mechanical relays:≤30 Switching time:≤30 Interface (digital):RS232C 3PIx-0xx-x0xx:FCC, 8-pin 3PIx-0xx-x1xx:D-Sub, 9-pin, male 3PIx-0xx...
Germany, Niederkassel
218km
... various construction heights and materials. It couldn't be easier! The Optima-Plus connection with crimp joint allows for simple and secure assembly – using tools readily available on any construction site. In three steps, all assembly phases are completed quickly and precisely – from cutting the trailing chamber to inserting the blue cap inner part into the switching chamber, and finally alternately tightening the screws and inserting the rubber end cap – all without gluing the switching chamber!
Germany, Oestrich-Winkel
155km
... the datasheet. Please contact us; we are happy to assist you in finding the right power supply for your project. Item No: 6367 Manufacturer No: SBU58-108 Number of output voltages: 1 - Single Output connection: Plug connector Design: PCB (Open Frame) Input connection: Plug connector Usable in region: Europe, USA / Canada, China Protection class: Class I...
Germany, Dettenhausen
223km
... cable and plug Sensor PT 100 1.6 mm Ø 250 mm long Sensor PT 100 2.0 mm Ø 250 mm long Sensor PT 100 2.5 mm Ø 250 mm long Sensor PT 100 3.0 mm Ø 250 mm long Sensor PT 100 3.0 mm Ø 250 mm long; Double... Dimensions: L x W x H 150 x 80 x 55 mm Connection: 1.20 m long connection cable with Schuko plug Output: 230V, two-pole switched Output current: max. 8A On-Off switching: Illuminated rocker switch...
Germany, Sankt Augustin
206km
... can be set with Add1 and Add2 to maintain the contact. The lower and upper switching points can function as either normally open or normally closed (changeover). All settings can be protected by a password. Features include zero point correction and switching of the pressure unit from bar to MPa or psi.
Germany, Neu-Ulm
237km
...The tread step contact strip is activated by a foot when stepped on, generating a switching impulse that leads to door opening/reversal. This system can also be retrofitted to inward-swinging, outward-swinging, folding, sliding, and pivot sliding doors for buses and trains.
Germany, Heilbad Heiligenstadt
95km
... contact and activates it. The repulsion between the similarly charged permanent magnets supports the buoyancy (version VK..deviating). As soon as the level drops again, the float follows and reactivates the reed contact. The level switches of the VK series are made of plastic and are available with various float variants and PVC jacketed cables. Switching function: Contact opens at falling level Nominal pressure: PN 10 Temperature ranges: Medium Max. 100 °C Ambient -25...70 °C...
Germany, Mühlheim
98km
... switching level + precise switching behavior + high repeat accuracy + durable and maintenance-free Various variant types available. Further options and customizations upon request. Contact us now at Tel: 0049 (0)6108 70010 We are here to help you.
Germany, Rödermark
108km
... and made available as an analog signal (adjustable 0/4..20mA or 0..10V). Additionally, the module features an adjustable switching point that can be set via a potentiometer. The state of the relay contact is indicated by an LED on the front panel of the module. The module is designed for use in control cabinets and for mounting on a DIN rail, operating with a supply voltage of 230VDC.
... the aluminum base plate, enabling a rapid response to temperature changes. The raised side parts of the insulating body provide extensive protection for the switching spring. Due to the open design, care must still be taken to ensure that the internal components of the fuse are not damaged. According to EN 60 691 for use in resistive circuits under normal atmospheric conditions.
... distance from the front film by a spacer film with holes at the switching contacts, ensures that when pressing the control symbol on the control film with a fingertip, the front and back films make contact. An electric current flows, and the switch is activated. High-performance adhesives are used to bond the various films. The spacer films can be applied in different thicknesses, and the control symbols on the control film can be represented in relief through embossing.
Germany, Wendlingen
212km
...Your benefits: Hold objects temporarily for processing, lighting, testing, etc. Allow for a gentle placement on the adhesive surface. Allow for careful positioning before activation. (Stop set to a specific measurement) Allow for effortless, gentle removal without risky jerks or force. Product features to your advantage: Very flat, square design. Load attachment via central hole M16x1 or 4 or 8 threaded holes M4. Switching operation with the thumb via a knurled wheel at half the height of the block. (90° rotation) Blued surface.
Germany, Hannover
212km
...{"Protection Class according to EN 60529":"IP 40 (see contact type)","Printing":"wet magnet (customer printing possible)","Switching Function":"3/2 Ways (2/2 Ways on request)","Thermal Class of Insulating Materials according to DIN VDE 0580":"F","Medium Quality according to ISO 8573-1":"Compressed air of quality class 3, 3, 3","Voltage Tolerance":"± 10 %","Electrical Connection":"USC","Ambient...
Germany, Ratingen
243km
... measurements according to the effective pressure method, versions with a square scale division are available. TECHNICAL SPECIFICATIONS: Operating Mode: Measurement Mode Measuring Medium: Air or non-aggressive gases Measuring Sensor: Mechanical Membrane Measuring Instrument Measuring Unit: Pa Smallest Measuring Span: 0…50 Pa (1 mbar) Measuring Range Selection: Factory preset Setpoint Adjustment: 2 setpoint indicators adjustable over the full scale range, 1 output relay with potential-free switching contact per limit value Storage Temperature: -25…+60°C...
...CO Control Center in BUS technology for up to 200 measuring points on 8 BUS lines and up to 45 illuminated signs Bus topology: RS485 Measuring sensor cable: JY(St)Y 2x2x0.8mm Alarm switching points: 5 (medium or measured value determined) Alarm output: Collective fault: 1 x potential-free changeover contact, 250V/2.5A, collective alarms: 3 x potential-free changeover contacts, 250V/2.5A, plus...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play