...With our in-house calibration laboratory, accredited according to DIN EN ISO/IEC 17025:2018, we provide calibration services for gas meter testing facilities. We cover the areas of gas volumetric flow measurement, temperature, pressure, relative humidity, and frequency measurement. This allows us to realize all relevant measurement parameters for a complete gas meter calibration system.
Germany, Bergneustadt
...AU Device Calibration Gas A 1.2 liters volume 10 bar results in 12 liters of gas mixture...
...The test bench is designed for calibration with critically operated nozzles of domestic gas meters or others such as diaphragm gas meters, ultrasonic meters, thermoelectric gas meters. The test bench is specially designed for the calibration of domestic gas meters (bellows gas meters, ultrasonic meters, thermoelectric gas meters). The test bench is modular - 1x6 to 4x6 clamping positions for...
Germany, Remscheid
... sensors (future-proof) Innovative • Measurement range 1ppm to 100% LEL (Methane = 44,000ppm)* • Gas sensor with linear characteristic curve (minimal aging)* • Low cross-sensitivity* • No false alarms from cleaning agents or alcohol* • Base unit "maintenance-free"! Only sensors need calibration. Each sensor operates on a base unit. (No calibration to the base unit necessary) • Internal memory for documentation (additional cost) • Color display 320 x 240 pixels • Innovative menu-driven operation • Device capable of software updates • Additional sensors in planning...
Germany, Stuttgart
...The BW Clip series of single gas detectors offers up to three years of maintenance-free operation. This means greater flexibility and no downtime. - Up to three years of completely maintenance-free operation - Automated test routine for increased safety - No calibration or adjustment required - No battery or sensor replacement - Compact, lightweight, and user-friendly - intuitive operation with...
Germany, Seligenstadt
Germany, Duisburg
...The ALTOSONIC V12 is a 12-chord ultrasonic custody transfer (CT) flowmeter for natural gas. It has been designed to offer the best possible measurement accuracy, not only during calibration under ideal conditions but also during less ideal conditions in the field. As a result, ALTOSONIC V12 is the first ultrasonic flowmeter that was certified to OIML R137 class 0.5 by NMi. Due to its design...
...The MF-CO type sensors are used for measuring toxic carbon monoxide in underground garages, parking facilities, and loading halls. Measurement gas: Carbon monoxide Signal transmission: Analog measurement signal, 4-20mA Connection technology: 24V DC (+), 4-20mA (GND) Calibration: All controls on the sensor, manual adjustment of zero point and gain directly on the sensor possible, microprocessor-controlled sensor calibration Signal generation: Via electrochemical measuring cell...
Germany, Thierstein
... the profile. Features: — Nominal pressures: 0 ... 400 mbar to 0 ... 600 bar — Accuracy: 0.25 % FSO BFSL (Class 0.2) — Rotatable housing — 2-line LC display, 4.5-digit 7-segment display, 6-digit 14-segment additional display — Various mechanical connections: inch, NPT thread — Ceramic membrane Optional features: — Min/Max function with reset capability — Zero point and full scale calibration — Pressure unit adjustment — Automatic shut-off configuration...
Germany, Köln
... calibration leak or calibration gas Input/Output:-RS232 -Audio line out -Digital 3 in/4 out -Analog out USB (slave) SD card reader Maintenance:none Power Supply:100 – 240 VAC, 50/60 Hz, 2 A Dimensions (WxHxD):305 x 165 x 182 mm (12 x 6.6 x 7.2 in.) Weight (excl. probe and probe cable):4.2 kg (9.2 lb.)...
Germany, Köln
...With us, you get everything related to gas warning technology! As a full-service provider, we supply and service all brands in the field of gas warning technology and offer both training and rental equipment. Starting from comprehensive, tailored consulting and planning to the commissioning and calibration of the devices. We also provide regular maintenance of the devices, as well as repairs when...
Germany, Essen
... mixtures - Certificate as a state-recognized testing facility - Express certification upon request Mobile Measurement and Analysis Systems: - Calibration-capable gas quality, volume measurement, and energy calculation - Calibration of gas quality reconstruction systems Operational Gas Measurement: - Inspection of volume and gas quality measuring systems/devices - Commissioning of measuring devices after new construction and renovation measures - Fault analysis and resolution...
Germany, Hohen Neuendorf Ot Bergfelde
...Gas warning device for oxygen, toxic or flammable gases, and CO2 True one-button operation Easy-to-read LCD display with backlight Clear and unambiguous indication of operational status 30 days advance warning for due calibration Acoustic 95-dBA alarm Striking red/blue visual dual alarm Internal vibration alarm 2-stage alarm Time-weighted average alarms for...
...Calibration; Inspection of fume hoods, safety cabinets, hazardous material cabinets - We offer you the following services in the laboratory sector: • Inspection of laboratory fume hoods, safety cabinets, hazardous material cabinets, centrifuges • Inspection of gas cylinder cabinets, acid-alkali cabinets • Calibration of CO2 incubators, incubators, and pipettes • Calibration of the parameters temperature and CO2 in laboratory equipment...
... glance via a three-color LED, green display = everything OK, yellow display = still OK, but a check is due soon, red display = not OK Particularly noteworthy is the loud alarm at 95 db and the optical signaling indicated by two LEDs that can be recognized from each side. The measured gas concentrations are saved every 10 seconds and stored in the internal memory. In addition, various events...
...10 litres calibration gas (100 ppm H 2 in nitrogen) for all FAN H 2 breath test devices. Compressed in an 1–litre aluminium can, at least 12 calibrations can be readily achieved.
... measurement values are in view, and the hot-spot display quickly and easily locates the core flow. Easy, intuitive operation, the latest technology, and an ergonomically shaped housing with a soft case and integrated magnets are just a few of the outstanding features of the Fyrite® INSIGHT® Plus. The B-Smart® sensor technology allows users to replace the sensors on-site, eliminating the need for factory calibration. A long-lasting O2 sensor is also available. The flue gas measuring device is fully equipped and ready for immediate use.
Germany, Villingen-Schwenningen
... PID sensor (Photo-Ionization Detector) -Long-term stable measurement results through automatic zero-point calibration. The integrated mini-catalyst reliably generates a defined reference gas for zero-point calibration.
...The extremely robust H2 sensors of the BCP-H2 series can be easily integrated directly into gas pipelines. Each H2 sensor independently measures the hydrogen concentration in the exhaust gas, for example, from fermenters with algae. The hydrogen sensor at a glance: • low investment costs • direct integration into gas pipelines • quick installation via standard connection • monthly calibration with fresh air • factory calibration with certified test gases Gas type: Hydrogen Measuring method: Thermal conductivity Type of measurement: In situ...
Germany, Hallbergmoos
...Gas cartridges for air quality measurements with Kunak Air Pro and Kunak Air Lite - Kunak AIR stations are sensor-based devices equipped with slots for inserting Smart Gas Cartridges. Kunak Smart Cartridges (CO, CO2, NO, NO2, O3, H2S, SO2, NH3, VOCs) address many of the known issues of sensor technology: sensor variability, factory and field calibration, automatic data invalidation, sensor...
Germany, Kirchzarten
... calibration certificate or a DAkkS calibration certificate. Measuring ranges: 250 / 500 Pa, 1 .. 100 kPa freely scalable from 10 .. 100 % Measurement accuracy: ± 0.2 % of full scale or ± 0.5 % of full scale (reference measurement accuracy 0.3 Pa, for measuring ranges ≤±1.5 kPa) Medium: Natural gases Housing: Surface-mounted housing IP 65 also suitable for DIN rail Output: 0 .. 10 V, 0/4 .. 20 mA, ± 5 V Power supply: 24 VDC...
Germany, Steinenbronn
...with integrated critical nozzle gallery With the nozzle calibration system CFO-1x5, we offer a very compact flow calibration unit that can be equipped with precise sensors and an electronic pressure regulator as needed. Up to five critical nozzles and their flow can be switched with valves in a nozzle gallery. The mass flow is summed up, and up to 32 flow points can be set.
Germany, Neufahrn
...The average turnaround time for a calibration at TrigasFI is only five working days – we understand that you rely on your measuring devices. And since measurement results are needed around the clock, we also offer a 24-hour emergency service in case anything should get "stuck". Advantages: • Primary standards for gas and liquid calibrations • Over 20 years of calibration experience • Our...
...• Requires no charging or calibration • Display shows remaining lifespan, gas values, or both • Cost-effective device with no maintenance requirements that alerts the user to a potentially toxic environment. • With these maintenance-free measuring devices, you can focus on the safety of your employees instead of worrying about your equipment • 2 years of continuous operation means your measuring...
... equipped with automatically maintenance-functions, which contributes to a considerable reduction of costs for maintenance and training. This multi-gas device is provided with an own software allowing individual and specific adjustments and data recording. Features of Protégé: Easy handling with calibration and operation self-test Complies with all requirements of global supervisory authority through robust construction Easily maintained is due to automatic zero- and span calibration and easy replacement of sensors Through special ergonomic shape of an hourglass, well suited for all hand...
... mass flow base on thermal dispersion theory. It combines COMATE’s advanced technology on transmitter, sensor, filming and calibration, can provide stable and accurate measurement even under harsh industrial applications and require very less maintaining.
...Expertise in various engineering fields • Material behavior and application range • Mechanical Design (Casting, Forging, Assembly) – Structural Strength / Integrity – CFD / Heat Transfer – Fatigue (LCF, TMF, HCF) – Bolted Joints / Welded Joints – Fracture Mechanics – Creep (standard, user defined) – Modal, Buckling, Spectrum • Test data Post-processing, Calibration...
...Delivery and installation of gas analysis and indoor air monitoring systems tailored to your needs Expansion of existing analysis systems, e.g., for monitoring activated carbon filters Monitoring and alarm systems for hazardous substances, such as hydrogen sulfide Calibration of the measurement system with certified test gases Maintenance and servicing of gas analysis and indoor air monitoring by our specially trained technicians...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play