...The CS400 is a modular system for non-contact measurement and monitoring of the surface temperature of rotary kilns. The system reliably detects so-called "Hot Spots" on the rotary kiln, which may indicate faulty linings. This helps prevent malfunctions or damage to the kiln and costly production stoppages. At the core of the CS400 system is an MP150 line scanner with 1024 data points per scan...
Germany, Berlin
... analog outputs as well as various optional digital interfaces. Temperature range: 50 °C ... 1800 °C Spectral range: 2.3 µm Optical resolution (90% energy): 22:1 (3ML)/ 33:1 (3MH)/ 75:1 (3MH1 - 3MH3) Response time (90% signal): 1 ms Weight: 420 g Power supply: 8-36 V DC...
... frequencies. As a result of the fire-risk evaluation according to EN 13463-1, the pneumatic timers are not subject to ATEX regulations. This means they may also be used in explosion hazardous areas as defined in IIG/ IID. Time intervall:3 - 100 s  Function:5/2-way  Pressure range:0 - 10 bar Type of pneumatic connection:M5  Ambient temperature:-10 ... +60 °C...
Germany, Menden
... to melt soaps, fats, varnishes and oil-based products, or respectively reduce their viscosity. The 200-liter element can be combined with the HBD - base drum heater to reduce the heat-up time. The heating element of the HTSD heating jackets is sewn into a fleece made of silicone-insulated fibreglass material. The insulating outer housing consists of a binder-free mat made of textile glass. The...
...), and can be used in a variety of environments (-40 to 80°C). The durability and compact size of the TR41A, along with its rapid response time to temperature changes, make it the perfect solution for monitoring cargo temperature during transport. "TR4 Report" is a specialized mobile application for creating PDF reports for a specific period. It allows for the creation, printing, and sharing of data reports in simple steps. Temperature range: -40 to 80°C...
Germany, Donaueschingen
...:-70 ... + 200 ° C, ± 0.1% of the measured value, ± 2 digits Sensor calibrated to the device Protection category:IP67 Housing:ABS Response time temperature:ca. 10 sec Display:two 4-digit LCD (12.4 or 7 mm) Application temperature:-25...50 °C Supply voltage:2 x AAA batteries Dimensions:(LxWxH) 67 x 106 x 30 mm Scope of delivery:HACCP thermometers with Pt1000 core temperature probe, 1x instruction manual on CD Weight:0.245 kg...
... chemicals. This allows for the bonding of various fiber products to ceramic and metallic surfaces. The high-temperature adhesive is ready to use and can be applied with a trowel or a brush. The drying time depends on the ambient temperature. Material specification: Mixture of inorganic chemicals Application temperature: up to 1100°C Classification temperature: 1200°C Color: brown/beige Density: 1600 kg/m³ Consistency: Creamy paste Material consumption: approx. 400 to 1000 g/m² Packaging units: 500 g can | 1600 g can | 25 kg bucket...
... Contactless temperature measurement has become indispensable in measurement technology, especially in conjunction with induction heating. Modern devices set new standards in low-temperature measurement technology for metallic surfaces. The development is based on the latest findings built on state-of-the-art technology. The proven alternating light method achieves excellent long-term stability and insensitivity to temperature shocks. With a response time of only 5 ms, these thermometers are also suitable for the fastest measurement tasks. For precise...
...SILCADUR-CSMH is an inorganic-based repair adhesive with a classification temperature of 1,300 °C. It is used for bonding dense calcium silicates or other mineral building materials to each other, as well as for repairing cracks, breakages, etc. in fireclay or vermiculite products within the fireplace. The drying time depends on the layer thickness and the environment (temperature, humidity...
... colour display and easy menu navigation. All important parameters can be seen at a glance and temperature curves are displayed in graphic real time. Unistats are equipped with the most up-to-date pump technology for optimal heat transfer. The pump self regulates to ensure the best possible circulation and flow and delicate glass reactors are protected from breakage by the pumps soft start-up...
...The ES Thermal Imaging System for Sheet Extrusion from Fluke Process Instruments features a variety of linescanning systems that provide continuous, accurate and real-time thermal images and temperature measurements for moving processes and product. Each system comes in a wide choice of spectral and temperatures ranges to accommodate a variety of applications. The series also features dedicated...
...Digital time, date, and temperature displays, multi-line representation of time and temperature, for indoor and outdoor use, digit height 100-180 mm...
Germany, Heinsberg
... °C Response time: <150 ms Spectral response: 8 ~ 14 microns Laser class: Class 2 (II) Wavelength: 630 ~ 670 nm Power: < 1 mW Display: LCD, monochrome Measurement range (contact temperature sensor): 50 °C to 300 °C Accuracy (contact temperature sensor): ± 1.5 % ± 3 °C Repetition capability (contact temperature sensor): ± 1.5 % Environmental conditions (operation): 0 °C to 50 °C, 10 % to 90 % relative humidity Environmental conditions (storage): -10 °C to 60 °C, < 80 % RH (no condensation) Technology: infrared Display system: digital Configuration: portable...
Germany, Bad Bellingen
...With SnowPack®, you get a dry ice pellet at -79 °C weighing 50 or 250 g in a very short time, without the need for expensive technology or a power outlet. This way, you can achieve economical cooling at the lowest temperatures at any time. Application examples: Lowering the temperature in cooling baths or cooling traps, pre-cooling of tissue samples, transport insurance or incorporation of...
Germany, Meinerzhagen
... on DIN 4754. Design and technical configuration of all temperature controllers are based on the requirements of this norm. Exact film temperature calculation ensures, in combination with flow monitoring, efficient and at the same time reliable operation in all operating conditions. A lockable filter in the circulating medium return line is a standard installation; another installed feature is an expansion vessel with a cold oil container for reliable prevention of damage by oxidation due to oxygen accumulation in the heat carrier. Display:digital Type:circulating oil Use:cooling,heating,process...
... * Examples of media: viscous cosmetic products, food, etc. Features & Benefits * Consistent flow rate * Easy and quick cleaning * Gentle, pulsation-free product transfer * Smooth operation and low wear * Wide selection of robust and powerful drive motors * Approved according to ATEX Directive 2014/34/EU, Category 1/2 * The maximum delivery rate is a determined value measured in a test stand with water at a medium temperature of approximately 20° C.
Germany, Köln
... be able to reach an extrusion temperature of 280°C and a print bed temperature of 120°C, and ideally have a heated build chamber. Without a heated build chamber, only smaller components can be printed. Delivery time: 1-3 days Filament diameter: 1.75 mm or 2.85-3.00 mm Net weight: 750 g Color: yellow Application temperature: -100°C to +120°C...
... Application: - Supply and preparation of medium to high-viscosity media, such as: silicones, adhesives, resins, fats, color pastes, metallic-filled pastes Dispensing volume, ml / revolution: ViscoTreat-R 3 / 15: ~ 4.0; ViscoTreat-R 3 / 18: ~ 7.5; ViscoTreat-R 3 / 22: ~ 13.5 Content: 15 / 25 l Max. speed: 150 rpm (depending on the dosing medium) Medium temperature: -20° to +100 °C (depending on the medium)...
Germany, Balingen
... coil helps you to enhance the quality of your products and to minimize the risk of possible recalls. INTUITY reliably checks if your packaged or unpackaged products or bulk goods include metal foreign objects. It is impressive in terms of its high accuracy: With its multi-simultaneous technology it checks at the same time with at least two frequencies within a range between 30 and 900 kHz Product temperature:-20 °C to +80 °C Operating conditions:-10 °C to +40 °C Material:Coil housing Tunnel Electronic housing IP rating: IP65 IP66/69...
... on the vehicle performance and the service life of the tyre. Range:0 to 200 °C Accuracy:2 % FS Ambient temperature error:2 °C Sensitivity:20 mV/°C Response time (0-90%):250 ms Signal:0.5 at 0°C V Supply Voltage:5 to 16 V Supply Current:1,5 mA Output Voltage:0 to 5 V Output Impedance:47 Ω Sensitive Element:Thermopile with Silicium Lens Wave Length:8 to 14 µm Measurement distance:30 to 150 mm...
... (2,700 K I 3,600 K I 6,500 K) • The lithium-ion battery provides a long operating time of up to nine hours • Even workplace illumination • High luminance levels of 1,000 lux at a height of 60 cm on the surface of the table • Direct and indirect illumination thanks to rotatable lamp head • Narrow tolerance binnings ensure high colour fidelity • Temperature management for a long service life of the LEDs of well over 50,000 hours • Made in Germany Colour:orange Material:aluminium Reference:923109...
...One-time triggering temperature safety device from 72°C to 240°C - Elmwood temperature safety device with over 50 years of product experience - Switch type: single-pole opening on temperature rise, non-resettable - Construction with switching contact and integrated organic melting element - Switching capacity (rated voltage and current, resistive load): 16.7 A 250VAC, 10 A 12 VDC, 5 A 24 VDC...
Germany, München
...This saves you valuable time and eliminates the need to invest in additional devices. Coordinated components enable quick and smooth installation as well as continuous and reliable measurements. Wireless, rechargeable multi-sensor unit for stationary device and environmental monitoring. Encrypted, secure, and wireless data transmission to your smartphone or 24/7 in connection with the scouter gateway to the essentim cloud.
Germany, Frankfurt Am Main
... container is extremely easy to use. Simply place your contents in the container and close the lid. You can use it either half or fully, so that fruit and vegetable leftovers maintain their freshness. 4. This freshness capsule is ideal for fruits, vegetables, and many other products. It can be used both in the refrigerator and at room temperature. 5. The ZWEIKELL FRESHBALL storage container is made from durable and food-safe material.
...Compact valve manifolds with low piping effort, reduced maintenance time and minimize investment costs. A connection system well known from the field of hydraulics and adapted to the respective application, allows for the intelligent combination of several valves in a customerspecific manifold. All necessary connections between the individual process valves are integrated in the manifold. Size:DN 15 - DN 50 Pressure:PN 40 Material:Stainless steel 1.4571 / 1.4404 / 1.4301 / 1.4305 Spheroidal graphite iron (EN-GJS-400-15) Media temperature:-30 °C to +200 °C...
Germany, Mühltal
... use with 500 ml ink bottles Operating temperature:+10 °C to +40 °C Max. air humidity:90 %, non-condensing Print distance for text:up to 12 mm Print distance for 1D/2D codes:up to 6 mm Weight Controller:3900 g Digital Inputs:6 Digital outputs:4...
Germany, Owen
... without the release of toxic gases (contains no isocyanate). · Resistant to mold formation · Completely removable with ABchimie SND or DNS solvents · Very good dielectric properties · Certified according to UL, IPC-CC-830, and NF EN 61086-2 The acrylic spray lacquer. The lacquer dries at room temperature in 5 to 10 minutes and fully cures after 24 hours. The curing time can be accelerated in an oven to 2 hours at 90 °C or 4 hours at 60 °C.
Germany, Breitscheid
...Extension of workability time, e.g. for bridging of extended transportation or installation times, avoidance of construction joints, reduction of temperature peaks, specially in massive concrete components. Retarder for all concrete applications including concrete for road decks and bridges.
Germany, Rastatt
... • Pneumatically driven film applicator with precise, maintenance-free 180° turning gearbox for retrieving sealing plates from the magazine and placing them on the sealing edge, secured by a pre-sealer • Sealing station for closing containers with control of sealing temperature, sealing pressure, and sealing time for optimal adjustment of sealing parameters, conductive, optionally also inductive...