... environments. In the area of partly or fully sunk in the ground supports, foundations and floors the underlying soil receives the cold. If the natural heat flow from the environment and the earth is insufficient, the moisture in the ground freezes, expands and the ground is lifted. Depending on the nature of the ground, this may cause substantial damage to buildings. Frost heave protection in cold stores and cooling chambers is, therefore, an essential and a reliable preventative measure against frost damage and damp.
Germany, Bünde
...Protection technology is essential for the safe operation of electrical systems. Our solutions protect against overloads, short circuits, and other electrical disturbances. They are suitable for various applications and help enhance the safety and reliability of your electrical systems.
... can be steplessly regulated by our built-in thermostat. It keeps the temperature of your choice constant between +5°C and + 30°C or just protects your room from frost. The red signalling light shows when power is on. Power:500W - 1000W Voltage:230 V Lenght:1040mm - 1840mm Protection mode:IP66 / IP67...
Germany, Köln
...For sealing openings, gaps, joints, and corners in all DIBt ZZ fire protection systems, as well as for use as an independent approved cable seal. The ZZ fire protection compound BDS-N (1K) can also be used for guiding cables through fire-separating building components (walls and ceilings) in accordance with the Model Cable Installation Directive MLAR dated November 17, 2005, and is suitable for...
Germany, Geisenheim
...GAT is a manufacturer and supplier of highly advanced Slip Rings and Rotary Unions. Further to an extensive range of standard products, we also provide individual solutions as your competent partner. Our Slip Rings are based on a modular system and are available with contacting and contactless transmission technology. Combined units comprising Rotary Unions are also available and can be realized as compact units. Compliance with specific directives or protection classes as well as certifications in accordance with UL/CSA can be provided on request.
... products for dry preservation: VCI dispensing systems Dust-free dispensing systems such as impregnated PU foams. Various carrier materials are available (papers, films, foams, etc.) → VCI packaging. VCI dispenser boxes for electrical and electronic applications.
Germany, Zella-Mehlis
... Connection external thread: R 1 1/2" Dimensions (L x Ø in mm): 928 x 100 Flange distance: 710 mm Weight: 8.0 kg Lamp service life: 10,000 h Dose: 400 J/m² Max operating pressure: 10 bar Enclosure protection class: IP 65 electrical connection: 110-240 V 50/60 Hz Power: 90 W Fuse: 10 A...
Germany, Kernen
...The PERFECT EMC cable gland made of nickel-plated brass is the ideal solution for the passage of shielded cables and wires, ensuring trouble-free operation of electrical devices and systems. Features: — quick and easy EMC connection — integrated strain relief for cables and wires — large sealing and clamping range — for cables with diameters from 3 to 44 mm — temperature range -20 °C / +100 °C (dynamic) -40 °C (static, short-term) — protection class IP68 - 5 bar Material: Nickel-plated brass Protection class: IP68 For cable diameters: 3 - 44 mm...
...Mechanical protection, reliable electrical insulation, moisture shielding, and heat dissipation – with continuously optimized casting resins (polyurethanes, epoxies, etc.) and casting systems, PRÜFREX is a leader in the field of vacuum casting. When it comes to the safe protection of your electrical and electronic components, our state-of-the-art, automated manufacturing facilities meet all...
...Maintenance, repair, and service of electrical and pneumatic smoke and heat extraction systems, hold-open devices, fire and smoke protection curtains.
Germany, Düsseldorf
... 62305 Part 1 to Part 4 • Grounding systems according to DIN 18014. Deep ground rods and potential control • Surge protection in low-voltage systems according to DIN VDE 0100-534 • Potential equalization in low-voltage systems according to DIN VDE 0100 Part 540 and Part 430 • Planning and revision of electrical documentation with E-PLAN...
... product series • Various locking systems, including M8, M12, and M16 • Coding options, including M12 - B, -D, and -X • Protection class from IP20 to IP69K • 2 to 8 contacts • Shielded and shieldable • PUR and PVC cables • Cable lengths from 0.5 m to 10 m...
... mechanical and electrical insulating properties in a single component. This enables more efficient systems that comply with industry-specific safety standards. Our high-performance plastics, classified as V-0 according to the fire protection standard UL94, offer you tailored solutions that are aligned with your specific needs. Our particularly robust plastic profiles contain neither red phosphorus nor halogens and feature excellent surface quality.
... mm, construction lengths from 400 to 1500 mm, extendable inner housing + 50 mm, base housing height adjustable + 100 mm, complete with base plate and impact plate as construction protection. Also available in surface-mounted version!
Germany, Mühltal
... Application: — Marking of glass, wood, rubber, engraving, and color change of plastics (automotive, medical, consumer goods) — Labeling of folding boxes and outer packaging (e.g., in the pharmaceutical, cosmetics, and food sectors) — Coated substrates (e.g., anodized aluminum) — Direct labeling of food products — Marking on laser color change — Engraving in color mirror Protection class: IP65...
Germany, Darmstadt
...Oil Filter for Rainwater From small oil filters for 5 liters/min of rainwater to high-performance systems for filtering oil-contaminated water with a flow rate of 1500 liters/min, for example, as environmental protection for electrical transformers. The filters prevent contamination of rainwater - after filtration, <5 mg of oil per liter is guaranteed.
...- Level monitoring for component A and B: Min. and pre-min. (potential-free contacts) - Pre-pressure monitoring analog or digital... Control panel: with 5.7 Electrical connection data (power supply) 1: 230 V, 16 A, 50 Hz (D/Dm) Electrical connection data (power supply) 2: 3x400 V, 16 A, 50 Hz (DTg) Housing: Steel, painted RAL 7035 Control cabinet size (WxHxD) 1: 600x800x250 mm (D/Dm) Control cabinet size (WxHxD) 2: 600x1000x250 mm (DTg) Protection class: IP 54...
Germany, Wertheim
... panic rising within you? This is now a thing of the past! Because our AMFE fights fires where they start - and it does so automatically. This way, you can keep a cool head in fiery moments. The AMFE Automatic Mini Fire Extinguisher Unit is to be understood as a small extinguishing device. It detects and extinguishes the fire within a closed housing, thus preventing the spread of the fire. The AMFE provides fire protection for your control cabinet, electrical distribution, and electrical systems as a small extinguishing system!
Germany, Schwäbisch Hall
...Waterproof Colors: light gray, dark gray, black Cable protection hose for industrial use, for electrical installations, control systems, switch cabinets, flexible, impact and kink resistant, good oil resistance.
...Electrical insulation of mechanical engineering components using thermally sprayed ceramic coatings In the production of thermal spray coatings, COATEC is one of the leading providers in Europe. The components coated with electrically insulating oxide ceramics by COATEC offer the following advantages over electrically insulating plastic coatings: - lower wear - improved corrosion protection...
...In contrast to digital locking systems, access control systems are used when door statuses need to be monitored and electrical or motorized locks need to be controlled. This is particularly true for doors along escape routes, emergency exits, and fire protection closures. However, elevators, barriers, and personnel turnstiles must also be taken into account.
Germany, Heiligenstadt I.ofr.
...Type USI Category Transformers Design Safety transformer (single-phase) Application For supplying electrical circuits or devices that are to be operated with protective low voltage (SELV, max. 50 V) (e.g., devices for materials testing technology, film welding machines, certain systems in the chemical industry and mining, etc.). Execution open design (IP 00, installation max. up to IP 23) with...
...Products for Industrial Cable Protection Systems – Safety Even Under Extreme Conditions Cables are often exposed to various safety risks: - Overheating - Cold - Moisture - Etc. Adequate protection is therefore essential if you want to ensure that all connected devices and applications function smoothly. At FRÄNKISCHE, you will find products for high-quality industrial cable protection systems...
Germany, Porta Westfalica
...if the user wants to position them quickly and to his personal needs. • Simplest and most cost-effective solutionfor hanging and free-standing operator stations • Quick and easy ergonomic adjustment • Continuous equipotential bonding • Maximum cable diameter: Ø 40 mm • Flexible and cost-effective connectionfrom round to square tube • Easy to retrofit – complete exchange of the existing suspension system is not necessary Material:Aluminium die-casting Temperature range:-5 °C to +70 °C Protection class:IP65 according to IEC 60529...
Germany, Meinerzhagen
... energy recycling, lowering the energy demand at individual stations, converting energy, or utilizing it multiple times simultaneously, and ultimately disposing of it sensibly. The result is a significant energy saving that leads to cost reduction and contributes to environmental protection. Feature: central, with heat recovery, for energy recycling...
...Small distribution boards are the control centers in residential buildings, offices, and medical practices, as well as anywhere that manageable electrical systems are consolidated in one or more fuse distribution boards. We offer grounded and protection-insulated circuit breaker distribution boards with depths of 120, 140, 210, and 230 mm, as well as other depths upon request. You can find more information about the different types and distribution board accessories in our brochures.
... general statements. For high-quality assessments of insurance claims, I am well-suited with my certification as an IQ-Certified Expert for Insurance Claims related to electrical systems. This certification also meets the professional requirements of insurance companies (5-170-K 09 V1), as well as the personal suitability according to 3-030-K 09 V1 of the insurance companies. To clarify the facts and explore the possibilities for creating an expert report, please contact me directly.
... where space or budget rule out an additional angle or speed sensor. For mobile use and for instant digital access to measurement data, the 8661 torque sensor is also available with a USB interface. Principle:Rotating Measuring range:0 N.m ... ± 1000 N·m Signal output:0 ... ±10 V / USB / 0 ... ±5 V Ratio:No dual-range / 1:10 / 1:5 / 1:4 Mechanical connection:Round shaft , Keyway Electrical...
...For fast determination of thermally-dependent interruptions in electrical circuits or components Avoidance of heat damage when soldering electrical components For heat protection of neighbouring components Shrinking of inner parts for removal of seized taper plugs, pins, plugs or bearing bushes Generation of shrink seats for assembly of inner parts For rapid temperature adjustment during...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play