France, Rillieux La Pape
..." machine controller, allowing for direct and quick programming without the need to configure your PLC system. It is a plug & play accessory: simply set the operating mode according to the "micro-percussion marking" model. The combination of the eZ150 and the pneumatic "micro-percussion marking" machine is the ideal choice when cycle time is the main criterion.
France, Gémenos
...electrostatic painting. Reduced lost height: ensured by the possibility of a direct coupling between the hoist and the trolley (to be specified at the time of order), otherwise the hoist's suspension hook attaches to the trolley's beam. CE marking: guarantees compliance with European Machinery directives. Phase loss protection that prevents the hoist from being used during phase reversal or phase loss. SKU: PALELEEFAM Lifting Speed: 1 speed, 2 speeds Capacity: 0.5T, 1T, 2T, 3T, 5T Length: 3m, 4m, 5m, 6m...
France, Guenange
...%) Input current: 16A or 32A Output voltage: 200/208/220/230/240 Electronic circuit protection Transfer time: 8 to 12ms Efficiency: 99% (linear load) Compliance: EN62310-2 Dimensions: MultiNET_ATS 16A: 275x440x44 mm (1U) MultiNET_ATS 32A: 275x440x88 mm (2U) 2 years warranty on electronics...
France, Clichy
... to our clients to answer all their questions and provide personalized advice for their electrical installations. Electrical issues can arise at any time, which is why we offer electrical troubleshooting services for all types of failures, whether for outlets, switches, lighting fixtures, or electrical panels. We are also capable of installing electrical equipment such as air conditioning systems, electric heating, and security systems.
France, Marcy-L'etoile
...Electric cable hoist 0.5T with electric trolley HPN 24 m lifting height 23 m control cable 400V three-phase power supply – 50Hz Control in 48VAC (including transformers, contactors) Upper and lower limit switches (slowdown then cut-off) and direction (slowdown then cut-off) Trolley designed for beam widths between 90 and 306 mm (to be specified at the time of order) SKU: 27635 Classification according to FEM / ISO: 3m / M6 Load capacity: 500 Kg Lifting: 1 strand Lifting height: 24 m Lifting speeds: 25/4.1 m/min Lifting power: 2.4/0.35 Kw Duty factors: 50/20% Direction speed: 20 / 5 m/min...
France, Montreuil
...Sections: Energy Doser/Switches, Regulations Timer for all applications, In-wall synchronous timer, delay, timer Energy Doser Description: cycle of repeated on and off switching. Non-linear adjustment from 10 to 100% Single-pole cut only Type MS 65 Description: In-wall synchronous timer Cut-off 16A 230V Bipolar inverter Audible signal at the end of the timing Ref. Time minutes MS 65 60 60 MS 65 120 120...
France, Paris
... from 8 a.m. to 5 p.m. on 01 87 65 30 80. 1st time range:0.1-360000 height:70 mm Number of switches:1 Control voltage 1:12-230 V Frequency of control voltage 1:50-60 Hz Supply voltage:250-250 V EAN/Gencode:4010957047443...
France, Huningue
... real-time information about the connected signal. It is used for pump control in the wastewater industry and for economical level measurement in silos. Input: 1 x analog (U, I) Output: 1 x transmitter power supply Power supply: Not defined...
France, Canejan
...connect to mains power and connect the battery. The mains power indicator on the panel lights up solid green. 1. Press the EVACUATION button: The red indicator lights up and the sirens operate for 5 minutes, after which the panel returns to standby mode. 2. Restricted alarm (if delay activated): The duration of the restricted alarm is set using Switches 1 to 4. When a manual trigger is activated, the ALARM indicator lights up and a buzzer sounds during the restricted alarm. It is possible to acknowledge the alarm process during this time...
France, Canéjan
...Forced-controlled relays / safety switches of class A EN 50205 on DIN rail Compact 22.5 mm format Six power contacts of class A EN 50205 Removable screw terminals Cycles up to a dangerous failure: B10d = 100,000 at 5A Max. closing time of the closing contact (NO): <15 ms (including bounce) Bounce time of a closing contact (NO): <4 ms Max. closing time of the opening contact (NC): <16 ms...
France, Grand Bourgtheroulde
...After thirty-two years in the building electrical trade, I have filed a set of patents for an invention that has been in the works for a long time! The ability to secure cables, tubes, conduits, and Plexo devices without a hammer drill! Yes, it is possible thanks to small "insert boxes" and chemical sealing resin. You could say I am the inventor of surface chemical fastening! As a side note, and...