Belgium, Jumet
...Dual independent process input meters. o A math function can be performed on both signals. o Any of the 3 meter values can have alarms, analogue output or comms by adding optional card. o Intuitive and easy programming (high flexibility) o Variable intensity display o 16 points scaling for linearisation o Programmable function keys/user inputs Analogue output 4 (0)...20 mA or 0...10 V 2 or 4...
Belgium, Rumst
... seconds, if The engine will not start 3 or 4 times, Please wait for 10 minutes and repeat the operation mentioned above. Specifications: Input Voltage (V) 1ph230 Frequency (Hz) 50 Input Power (W) 12V 700 24V 1100 Rated Output (A) 12V 35 24V 35 Start Current (A) - 300 eff Battery Capacities (Ah) - 30-450 Adjustment Positions - 5 Output Fuse (A) - 1*50 Protection Grade - IP20 Reference:WM-CD-530 EAN:0634158802119 (L x l x H):60.00 cm x 26.00 cm x 31.00 cm Box Dimensions:60cm x 26cm x 31cm...
Belgium, Chaumont-Gistoux
.../250 VAC. Characteristics of the Releco relay: Ambient operating/storage temperature: -25 to 60°C/-40 to 80°C Voltage test between input/output: 4Kv rms/1 min. Pick-up time: max. 1/2 cycle Output time: 2 ms + 1/2 cycle Weight: 28 g.
Belgium, Anderlecht
...For motor: CVX/4T CVX/6T CVX/8T Suitable for indoor use, protection rating IP20. External control terminal. Control panel with digital display. Three-phase input / three-phase output (3x400V / 3x400V). EMC filter (electromagnetic compatibility). Input frequency: 4862 Hz, output frequency: 0500 Hz. Accepts a 150% overload for 60 seconds (175% for 2.5 seconds). Intensive operation up to an ambient...
Belgium, Herstal
...Transmec Group has been specialising in shipments, transport and logistics since 1850. Over the years, we have used our knowledge and expertise to deliver customised solutions that not only meet, but exceed the specific needs of our customers. Address:4ème Avenue 39, 4040 Herstal Covered area:2,250 sq m Eaves height:6 m Pallet spaces:1000 Number of input docks:3 Number of output docks:3 Vehicles input/output:45 per day...
Belgium, Schoten
...The B1205S-1WR2 dc/dc converter features a fixed input and an isolated & unregulated single output. These units from Mornsun are extremely reliable and have a long lifespan of 3500 K hours. They come in a miniature DIP package and have a power output of 1W.
Belgium, Waterloo
...The small ultrasonic sensor in a rectangular housing Construction similar to many optical sensors, a genuine alternative for critical applications Switching frequency up to 250 Hz for fast sensing Optional with SoundPipe focus Synchronization input 1 switching output in pnp or npn version Analog output 4–20 mA and 0–10 V 5 detection ranges with a measurement range from 20 mm to 1 m Teach-in microsonic via a push button Resolution 0.08 mm Operating voltage 20–30 V...
Belgium, Naninne
... - Airflow management. - Visualization of error codes with alarm history. - Advanced calendar functions with scheduled initialization. - Management of input/output signals. - Energy counting option. - Touch option. Data Analyzer function: It allows access to energy consumption information via a dedicated utility installed on a computer connected to the Smart Manager**. In graphical form, you can analyze the overall electrical consumption of the system as well as unit by unit. It is possible to compare, over 2...
Belgium, Temse
... completely counter clockwise. The input voltage for this potentiometer can lie between 0 - 24 VDC. The version handling 0 - 12 VDC is called the MTP-X10K-NA. The splash-proof housing of both potentiometers allows flush (IP44) or surface mounting (IP54).
Belgium, Herentals
...The machine can process both open and already sealed packages. Options: - extra pressing system - customized input and output systems - buffer for greater autonomy Applications: - olives - salads - sliced vegetables - soups - sauces - mayonnaise - paint or other chemical products ...
Belgium, Gullegem
... processing. KEY FEATURES Efficient storage and retrieval of raw materials Continuous material flow for uninterrupted and lights-out production Optimized use of floor space Highly reliable automated production PRODUCTIVITY-ENHANCING OPTIONS Direct unload station Input/Output (I/O) tower station 16 possible system configurations MODELS Available for Phoenix and Electra series (TAS 3015, TAS 4020 and TAS 6020) Specifications 3-ton capacity per pallet (5-ton for 6020) Up to 63 pallets, depending on system configuration Stack height of 90 mm...
...A simple installation with preservation of the configuration system - Ability to customize the WINATEQ software for the customer - Displaying and storing results (Output/Input in a table) - Visualization of the screens of the measurement modules (steps during the test, results,...) - Management of access levels (operator, responsible, supervisor) - Measurement module ATEQ and storage on the PC...
Belgium, Ans ( Liege )
...Wireless magnetic contact with wired output: Its magnetic sensor reacts to the opening of a door or window. It has an input terminal for external sensors (with NO or NC output).
Belgium, Welkenreadt
... optional battery pack or solar panels. The IFQ LOGGER keeps the same easy configuration enhanced by the IFQ MONITOR and stays in line with the flexible and modular architecture launched by the RAVEN-EYE. All flow sensors are field interchangeable. A dry contact output is available for users needing an output for samplers or any other instrument. KEY FEATURES: 1 x RS485 digital sensor interface for velocity (RAVEN-EYE or BELUGA) 1 x 4-20 mA analog input for level sensor 7 position sealed membrane keypad 2 Gb memory (SD card) Power supply : 9 to 18 VDC Enclosure: PPC (IP67)...