China, Dachong
... a liquid polyurethane resin which with the use of additives can simulate the properties of a wide variety of plastics. Between 15 and 30 parts can be produced depending on the requirements of the material and surface finish. This method is ideal for the production of small batches and prototypes in which the production of expensive injection molding tools is not feasible. Industries Applied:SCIENTIFIC INSTRUMENTS Industries Applied:MEDICAL DEVICES...
Germany, Ettlingen
...The German Technical and Scientific Association for Gas and Water (DVGW) and the Austrian standardization committee have defined the requirements for UV water disinfection systems with UV low-pressure lamps in DIN 19294-1:2020-08. This also specifies the design, function and opening angle of DVGW reference radiometers. The previous technical rule W294-3 and ÖNORM 5873 continue to apply to devices...
United Kingdom, Harrietsham
...Looking to improve you medical system? Then look no further. Knight Optical presents to you their Dichroic colour filters range. These Dichroic colour filters are typically used in scientific instrumentation or/and medical systems in particular palm vein scanners, ophthalmic diagnostics, professional eye care equipment from optical equipment or ophthalmic instruments. Our Dichroic filters...
Germany, Bad Bellingen
... sampling scoop, we placed particular importance on ergonomics; thanks to the special handle design and the slightly angled front edge, the scoop stands horizontally, allowing it to be set down without spilling the sample material. – White, white bio, blue, or blue detectable – Single-use, optionally sterilized...
France, Canéjan
...Let's define together your brand image, its scientific orientation, and its marketing positioning.
...Unlock the power of component analysis with Sciospec's LCR-1! Electrical component analysis has never been easier. Based on the same technology as our industry leading impedance analyzers, the LCR-1 combines next-level performance with the simplicity of an LCR meter. In terms of range, accuracy, and speed, the LCR-1 sees eye to eye with competing high-end devices while maintaining a compact form factor, simple setup, and ease of use previously unseen in this class.
Matching products
LCR-1
LCR-1
Other products
ISX-3
ISX-3
France, Saintes
Dynasource is a wholesale company providing support services for businesses in their merchandise import projects. Our company has a wide network of manufacturers in Asia, including a partner purchasing office in China. We also collaborate with European manufacturers. With 12 years of experience, we have expertise in a variety of sectors: Electronics, home appliances, decoration, textiles, toys, pr...
...Vienna Scientific has developed the automatic feeding station IR-401 for the established FAO/IAEA tray and rack system for rearing insect larvae in medium-sized facilities. Our feeding station is designed to dispense precise and uniform amounts of liquid feed into the stacked larvae rearing trays, thereby reducing the labor involved in feeding and minimizing the risk of human error or contamination. The feeding station can be easily adapted to other liquid feeding applications for tray and rack systems.
Germany, Kirchheimbolanden
...The MAX series cameras are high-quality devices featuring a large sensor, integrated active cooling technology to reduce sensor noise, and USB 3.0 for fast data transfer. These cameras are ideally suited for dark field imaging, astrophotography, UV imaging, etc., in the scientific and technical fields. The cameras can be delivered either with an M52x0.75 mm thread or with the standard C-Mount...
France, Saint Genis Laval
... engineers have been managing the after-sales service for major brands of laboratory scientific equipment such as Bruker, Brookfield, Thermo Fisher, and Tinius Olsen for several years. We handle the after-sales service for several brands ourselves and maintain a stock of products and spare parts to send to clients if needed, allowing us to be even more responsive during on-site interventions.
France, Toulouse
...Thanks to the expertise of its chemists and toxicologists, Toxi Plan® is able to offer its services to assess the biological safety of your medical devices. Toxi Plan® handles the characterization of active ingredients and degradation products in the medical device. We collaborate with laboratories that have all the scientific equipment to perform the following techniques: - UV-Vis spectroscopy...
...We specialize in the marketing, calibration, and verification of devices in the following areas: • Metrology and Calibration Standards (Non-contact measurement, calibration blocks, dimensional calibration accessories, …) • Scientific and Laboratory Equipment (Oven, microscope, precision balance,…) • Test and Measurement Instruments (Cable fault locator, hydraulic test pump, high voltage system...
France, Couëron
...In scientific and biological research, it is essential for researchers to obtain accurate and reliable results in order to draw valid conclusions from their experiments. This is what the Memmert brand is committed to providing to laboratory technicians by developing its range of climate chambers and constant climate chambers.
Italy, Fossalta Di Portogruaro
...High-tech instrument for biological testing of anaerobic digestion. Complies with VDI4630 and UNI/TS 11703 standards.
Germany, Erligheim
... cable with a Schuko plug. Features: • Reduced power consumption due to electronic holding current reduction • Prevention of valve internal parts from seizing through automatic daily valve closing pulse • Nominal diameters from DN10 to DN50 • Connections G1/2 to G2 • Piezo buzzer alarm • LED operating voltage indicator • Drinking water approval available upon request Function: After switching on the mains voltage, the electronics open the solenoid valve. The sensor detects a water film of approximately 0.5 mm and sends a signal to the control electronics. The valve is then closed.
France, Montpellier
...Compact temperature, humidity, and light recorder for transport or use as a Bluetooth® connected sensor with a Cobalt X™ recorder.
...the BlueInOne Ferm operates independently of flow and humidity, ensuring the highest accuracy and reliability. The BlueInOne Ferm can replace space-consuming central analyzers, which often pose a safety risk. This PAT and QbD-compliant combination sensor represents the latest technology and can be easily integrated directly into the exhaust stream of your bioprocess. Measurement subject: Oxygen, Carbon Dioxide, CO2/O2 Measurement parameter: Concentration Configuration: Benchtop, Integrable Additional features: Sensor, Laboratory, Process, Infrared...
... This product is both simple, reliable, and robust, equipped with a clipper to facilitate the positioning of the device on containers or tanks. Need more information? Feel free to check the product page on our website!
France, Wasquehal
...Everything you need to transform tap water into Type 1 pure water - This package includes: > Arium Mini Plus UV > Arium SterilePlus (final filter) > Arium Mini Plus pretreatment cartridge > Arium UV lamp > Arium Scientific Pack > Arium Bagtank (5-liter bag) The compact Arium Mini laboratory water purification systems are designed to meet your Type 1 water needs. With a production capacity of up...
Spain, San Sebastian De Los Reyes
... you: Coriolis, differential pressure, vortex, magnetic, ultrasonic, turbine, and positive displacement. Represented companies: - Emerson Automation Solutions - Trigas FI - Trigas DM - Alicat Scientific - Katronic - Fluidwell - Dosch...
France, Saint-Quentin-En-Yvelines Cedex
...HPLC Columns for Varied Selectivity Separations When developing your methods, you want to leave nothing to chance and need to know for certain if your columns are suitable. To make an unequivocal choice, opt for Waters' Spherisorb columns, one of the most cited HPLC columns in the scientific literature. There are over 2,000 publications referencing Spherisorb columns. These offer a vast number of...
France, Montpellier
...APPLICATION AREAS: - Hospitals - Pediatric hospitals - Blood donation centers - Pharmaceutical companies - Food analysis laboratories - Scientific laboratories in universities - Forensic laboratories - Paternity testing laboratories...
Belgium, Brussels
... map, making it the preferred method for testing hatches by charterers, freight forwarders, P&I insurers, and other stakeholders in the maritime industry. Another first for SDT is that the further development of testing instrumentation led SDT to launch in 2000 the world’s first Type Approved SHERLOG product range. Since then, SDT’s SHERLOG instruments have become synonymous with reliable and professional hatch tightness testing.
...The elasticity measurement machine EMM is used to measure the spring travel and elasticity in chassis joints in two load directions. After placing the test object in the measurement machine, it is clamped on both the housing and pin sides. The force-controlled loading devices first move the joint pin against the joint housing in the axial direction and then in the radial direction. Using a...
Italy, Roma
... specified temperatures - Storage of liquids and samples for physicochemical analysis Available models: - BASE, COMFORT, PREMIUM Controller: - Smart and Smart PRO Special models: - FOT – photoperiodic system – day and night simulation TECHNICAL DATA - Air convection: forced - Chamber capacity [l]: 70 / 70 / 70 - Working capacity [l]: 55 / 55 / 55 - Controller: microprocessor PID - Display: 4.3...
...The firm Optonom Scientific Instruments provides the ability to conduct optical projects professionally for national and international companies, institutions, or individuals through design, engineering, and manufacturing, along with consultancy services. Our company represents TracePro, OSLO, and RayViz software in Turkey. Particularly, Optonom is actively engaged in designing original new...
ufs.country_names.RU, Moscow
... for academic and industrial applications. Features: - A wide array of functions due to various attached modules and detectors - Capability of additional external devices connection for IR spectrum registration - Stability to temperature fluctuation and vibration due to unique patented interferometer design - Humidity resistance because of ZnSe optics - Spectrum recording control buttons on...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play