...Made from galvanized sheet metal, our booths can handle a flow rate ranging from 7900 to 19800 m³/h, with a capture length between 2 and 5 meters. It is also possible to create segmented booth compartments to increase the surface area to be treated (and thus the flow rate). Capture speed = a minimum of 0.4 m/s, regardless of where the measurement is taken. The paint booths can be equipped with...
Germany, Hammelburg
...Filter regulator Temperature range: -10° to +60° C Category Compressed-air technology / Compressed air preparation / Filter regulator Product number supplier 301804337 Adj.-range bar:1,5 - 12 Flow rate l/min:11500 Inner thread:G 1"-11 Measurement connection thread:G 1/4"-19 Series:3 Zollnr:84811005 Weight:1 kg Content:1 STK Barcode:301804337 Price Unit:1 Packaging Unit:1 quantity min:1 VAT key:19.00 %...
China, Shenyang
We supply instrumentation and field communication electronics for our clients from all over the world . You will find HART, Profibus, Fieldbus protocol pressure transmitters, temperature transmitters, protocol converters, and WirelessHART products here. What's more we are specialized in OEM service. We provide module, chips,boards, junction box, hart modem, communication controller, gateway, adapt...
Germany, Katzhütte
...The melt flow index (Meltflowindex, MFI), also known as the melt flow rate (Meltflowrate, MFR), is measured according to DIN EN ISO 1133. It is used to determine the flow properties of plastic melts and is expressed in g/10min. Our modern measuring devices undergo annual calibration to ensure the most accurate measurement possible.
Germany, Villingen-Schwenningen
...The DS 400 set for consumption measurement displays the current flow rate in m³/h, l/min, etc., as well as the consumption in m³ or liters, and reliably and automatically records the values.
Netherlands, Putten
...Venrius' portfolio includes a variety of variable area flowmeters. Metal tube variable area flowmeters, glass tube variable area flowmeters, and purge rotameters are the three main types. The volumetric flow rate of liquids and gases is measured using the float principle in metal and glass tube flowmeters. The purge flowmeter is intended for general use as a low-cost method of flow indication. It is suitable for the majority of non-critical purge applications that do not necessarily require high flow measurement accuracy.
France, Huningue
...Heartbeat Technology ensures compliance and process safety at all times. Maximum measurement error Volumetric flow rate (standard): ±0.5 % of m. ± 1 mm/s (0.04 in/s) Measuring range: 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2,650 gal/min) Product temperature range: –20 to +150 °C (–4 to +302 °F) Maximum process pressure: PN 40, Class 150, 20K Coating: PFA...
Germany, Asslar
... of physical values such as temperature, pressure, humidity, fill level, positioning, vibration, flow rate, power, torque, speed, ultrasound, infrared, composition, and concentration of gases and liquids, as well as adherence to measurement tolerances and production control, are of utmost importance.
... millimeter of strip thickness, they meet the demands of modern rolling mills. Contact measuring devices adapt to the strip flow and follow wavy material. Measuring material: Metal strip Maximum strip temperature: 120 °C (up to 200 °C with increased measurement uncertainty) Measurement resolution: 0.1 µm Sampling rate: 1 kHz Integration time Ti: 1 – 2,000 ms Protection class: Measuring head: IP64; Pneumatic cabinet: IP55; Control cabinet: IP55 Compressed air supply: Pressure: min. 5 bar; Volume: max. 7 m³/h...
...Orifice plate is installed on pipe line to ensure evolution of fluid cross flow section (by 1 orifice) in order to create calibrated differential pressure loss. The measurement of if by 1 or x pressure taps pair(s) allow to define fluid flow rate. Process norm: NF EN ISO 5167-2, ASME MFC-14M, ASME MFC-3M, ASME PTC 19.5 Construction code: NF EN 13480, RCC-M, ASME, CODETI SPM capability: DN15 to DN1000...
Germany, Hohen Neuendorf Ot Bergfelde
...The FST030 is designed based on the latest developments in digital signal processing (DSP) and is optimized for high measurement performance, short response times, high immunity to process noise, and easy installation, commissioning, and maintenance. The FST030 measuring transducer provides precise multi-parameter measurements of volumetric flow, standard volumetric flow, density, mass flow...
Germany, Crailsheim
... technology, cold-welded · Load cell supply 10V · Connection 4/6-wire · Sensitivity 1mV/V-4.0mV/V · Maximum number of measurements 4000/s · Accuracies: · Zero point 0.001% / K · Weight 0.002% / K · Load above nominal load 0.002% · Weighing range freely adjustable · Measurement value filter multi-stage · Filter stages adjustable · Serial interface TTY (20mA Current Loop). · Transmission rate 1200 Baud, 9600 Baud · Corner adjustment integrated via software · Calibration capable...
... the outlet flow of the test part. The design of the measuring section results in laminar flow. The resulting pressure difference is directly proportional to the volume flow rate. With the optionally available electronic pressure regulator and flow calibrations at up to four measuring section pressures, the application range is expanded. Special variant: The CETATEST 915-G is a fully automatic flow...
...TGF600 Screw-in thermal mass flowmeters for small pipe size gas meausred Inline type can be installed/removed without stopping the line Minimum flow rate down to 0.3m/s, 1:100 super wide turndown ratio No moving part, almost no pressure loss Direct mass flow measurement, do not require temperature or pressure compensation TGF600 Series screw-in inline thermal mass flowmeters measures the gas...
...Jerko flow measurement is a unique success story since the beginning of the project. At the request of the German Massivumformung e.V., a sensor system for the reliable detection of spray quantities was developed. Of course, the partners of Massivumformung e.V. could rely on the innovative power of Jerko and now have the possibility to monitor their process even better. The sensor is suitable for...
Germany, Windeck
...The Coriolis measurement principle allows for the determination of volumetric flow by measuring the flowing mass flow rate—regardless of the conductivity of varying media. In addition to mass flow, temperature can also be measured with high accuracy, as well as density. It is also suitable for measuring technical gases. We offer a variety of manufacturers in our product range.
Germany, Springe-Eldagsen
...The Minneapolis FlowBlaster, with a measurement range of 17 to 500 m³/h, has been specifically developed to control ventilation systems in residential and commercial buildings. In combination with the BlowerDoor MiniFan, it accurately measures the flow rate at the supply and exhaust air outlets. Measuring the supply or exhaust air flow rate indicates whether the planned target is being met. If the measured flow rates at the ventilation outlets differ from the target, adjustments can be made to the ventilation system.
Türkiye, Yenimahalle/ankara
...Measuring average volumetric flow rate in flow directions - Totalizing volume of flows independently or calculating their algebraic sum with regard to flow direction - Determining the current value of flow velocity and flow direction - Outputting measurement results to the frequency/pulse or logical output - Logging of measurement data and configuration settings in the internal nonvolatile...
Germany, Zimmern
... temperature regulation, the combiloop CL5 leaves no wish unfulfilled. Equipment:Size variable on request, weight depending on the stage of expansion Flow rate:Low-pressure system delivering up to 200 l/min Pressure:Depending on flow rate up to 1,200 bar Filter fineness :Automatic filter (40 μm), full flow filtration, desludging into wire mesh collector Operation:Cutting oil Water emulsion (min. 8 % oil content) Service connections:Up to 12 controllable service connections...
...The durability of a coated test specimen against the loss of adhesion strength is tested with a defined water jet pressure. The extent of damage to the test specimen depends on: - the adhesion strength - the distance of the nozzle to the test body - the flow rate - the testing time - the geometry of the nozzle - the impact surface and the impact angle - the water temperature of the test jet as well as on the cutting or scoring tool. The subsequent evaluation is carried out based on a visual comparison.
Spain, Tobarra (albacete)
...) ±0.30 or ±5 % of the value (Range: 5...30 m/s) - Temperature: ±1 °C Measurement Rate: Approx. 0.8 s Thermal Probe - Telescopic thermal sensor - Length: 210 mm (not extended) - Length: 426 mm (extended) - Diameter: 12 mm Display 2" LCD display, 170 x 220 pixels Interface Micro USB Environmental Conditions 0 °C ... 50 °C / <85 % RH, no condensation Power Supply Internal battery, 1000 mAh Memory Yes, for 10,000 values Device Dimensions 145 x 50 x 35 mm (without the telescopic probe) Weight 156 g...
Italy, Mo
...The T9731 is specifically designed for measure the adequate air flow rate in complete adherence to the standard EN 14683 for surgical masks testing. As shown in diagram C.1 on page 12 of the standard EN14683 , the instrument is equipped with two air flow meters of type Mass-flow with scales 0.0...20.0 nLitres/minute (2.12 of diagram - point C.2.1) servo driven valve controlled from the...
Germany, Kirchzarten
...The P 26 is particularly suitable for pressure control in clean rooms, laboratories, pharmaceutical plants, operating rooms, and for special applications in the field of mechanical engineering. The device measures not only differential pressure but also positive or negative overpressure, as well as flow velocity or volumetric flow rate. The measurement ranges are programmable from 10 to 100%. Two...
Germany, Neufahrn
...Our well-known CFlow+ LabVIEW-based data software offers a user-friendly interface. This type of calibrator provides truly exceptional accuracy and stability through the use of advanced computing algorithms and compensation techniques. Specifications: Measurement principle: LFE, secondary standard Flow rate: 0.001 to 1000 l/min (0.000035 to 36 ACFM) Pressure: up to 12 bar (test specimen) Measurement uncertainty: +0.25% of volumetric flow, typical Test specimen inputs: TTL pulse, magnetic pickoff, HF pickoff, visual, analog (0-10v, 4-20mA, etc.)...
...Application Examples FLOW MEASUREMENT and/or LEAK TESTING Cookers, ovens, gas burners, valves and flaps, lighters, valve seats and combustion chambers, engines, gearboxes, front and rear automotive optics, exhaust pipes and systems for cars and trucks, smoke and gas circuits for boilers, hydraulic blocks for construction machinery and trucks, all types of valves, membranes, sprays, aerosols, pumps, injectors of all types, hydraulic components,... For more information: md@aduplom.be...
Germany, Freiburg
...Sitrans FUS 3300/FUS060 • ATEX approved • Steel pipes DN 50 … DN 300 (2" … 12") • Pressure ratings PN 10 ... PN 40 or Class 150 … Class 300 • Flow rate 0.3 … 3,200 m³/h (1.3 ... 14,089 GPM) • No pressure drop • FUS060 transmitter for separate installation • The signal cables from the transmitter to the transducer are excellently protected from aggressive environments by stainless steel pipes...
France, Saint Genis Laval
... second - Standard sampling flow rate: 16 atm cc/min - Optional sampling flow rate: <1 atm cc/min to > 20 atm cc/min - Options for gas sampling corrosivity: yes Field of use: Real-time gas and vapor concentration analysis Simplified configuration and operation from template files: Quantitative data output and data export for up to 32 species Real-time data display in graphs and tables: OPC data available as raw data or quantitative output in %/ppm Automatic calibration with background correction: Gas/vapor mass spectrum library with intelligent scanning function...
Italy, Povoletto
...Composed of a separable electronic unit, single jet meter, Pt 1000 temperature probes For inline installation Installation at inlet or outlet and measurement unit configurable in the field Wireless communication interfaces: MBus, wireless MBus + 3 pulse inputs, MBus, MBus + 3 pulse inputs, 2 pulse outputs, LoRaWAN + 3 pulse inputs Replaceable battery, lifespan 10 years Prepared for external power supply MID certified Nominal flow rate qp: 0.6 m3/h, 1.5 m3/h, 2.5 m3/h...
France, Eybens
...Pressurization unit for resistance cycles SKC-100 Pressurization skid for the resistance cycle in trunnion valves. The system provides a total leakage flow rate of 0.7 l/min (0.5 l/min on the descending side and 0.2 l/min in the cavity). The control system can be directly connected to an axial piston motor to perform the opening and closing movement on the test valve with adjustable torque. The...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play