France
Manufacturer/ Producer
COMITRONIC BTI
France
RFID sensor with 16 million codes Category 3 total security management without an external controller Programmable code through auto-learning (no software or PC) Level of performance with AWAX controller: up to PL = e Safety category without an external controller: 3 (EN 954-1) Cycle after dangerous failure: B10d = 2000000 at 2 Amps Max activation distance: up to 24 mm Security contact/diagnostics: 2 x redundant NO 2A/48V and 1 x 400mA PNP auxiliary Detection encoding: inviolable multicode Indicator: LED indicates code recognition Reset: automatic Attachment: 4 tamper-proof M4 screws (in base option: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm PUR cable with M12 connector (base + MKT) Sealing: IP 67 Temperature: -20 °C to +60 °C Marking: pad printing + serial number for traceability
Request for a quoteCOMITRONIC BTI
France
NF EN ISO 14119 provides measures restricting the possibility of reasonably foreseeable fraudulent neutralization on locking devices. Some drawbacks The key does not provide inviolability. This system has problems related to minimum radius, alignment and breakage when operating the key. The switch often has only one door position contact and two locking contacts. For maximum performance level PL = e, a position sensor must be added with redundant outputs. This overburdens the wiring, occupying 4 inputs on a safety PLC.
Request for a quoteCOMITRONIC BTI
France
Contactless "door lock" encoded detection Unlock command with just one contact during serialization of products • Cycle before dangerous failure: B10d = 1,000,000 at 200mA • Bolt travel: 9 mm • Bolt diameter: 12 mm • Shearing strength: 1000 N • Distance between latch and lock: 0 to 4 mm (adjustable when assembling, recommended to 4 mm) • Maximum lateral displacement between strike and lock: +/- 0.8 mm • Maximum angular displacement between strike and lock: +/- 5° • Safety locking contacts: 2 x NO 0.4A /24V redundant and • Unlock command: PLC-compatible (12~30 VDC/2~5 mA) • Diagnostic error: Auxiliary output indicates unlocking • Reset: on command • Infinite automatic offset control when connected in series: minimal consumption • Auxiliary release: key supplied (free key in lock mode; captive key in release mode) • Attachment: 4 M4 screws (screw covers included) • Mounting position: 1 • Material: PA6 fiberglass reinforced • Electrical connection: very resistant 50 cm or 130 cm PUR UL20549 cord with M12 connector or cable (contact us) • Water resistance: IP 65 • Ambient temperature: -5°C to +40°C. • Marking: screen printed + serial no. for traceability
Request for a quoteCOMITRONIC BTI
France
Contactless "door lock" encoded detection Contactless "door open / closed" detection Unlock command with just one contact during serialization of products Emergency evacuation handle • Level of performance with AWAX controller: up to PL = e Safety category with an external controller: up to 4 • Cycle before dangerous failure: B10d = 1,000,000 • Bolt travel: 14 mm • Bolt diameter: 24 mm (beveled for "under-voltage" closed position or "lock" mode) • Shearing strength: 2000 N • Gap between strike and lock: 2 to 4 mm (adjustable when assembling, recommended to 4 mm) Maximum lateral offset between strike and lock: +/- 2.5 mm • Maximum angular displacement between strike and lock: +/- 5° • Safety locking contacts: 2 x NO 2A/50V • Safety door contacts: 2 x PNP/500 mA • Unlock command: PLC-compatible (12~30 VDC/2~5 mA) • Fault Diagnosis: bolt stuck, power out of specification, temperature out of specification, electromagnet failure, serialization failure • Reset: on command • "SMART consumption" for minimal power consumption when connected in series • Auxiliary release: female triangle key 8 mm x 14.2 mm (optional) • Attachment: 4 M6 screws (screw covers supplied, screws not included) • Mounting position: 2 (door pulling, door pushing) • Material: PA6 fiberglass reinforced • Electrical connection: very resistant 50 cm PUR UL20549 cord with M23 connector or cable (contact us) • Water resistance: IP 65 • Operating temperature: -15°C to +45°C • Marking: screen printed + serial no. for traceability • Reference for evacuation handle: AT
Request for a quoteCOMITRONIC BTI
France
No power or under-voltage locking on machine casings Machine protection closing control for harsh environments Antimicrobial handle available Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with AWAX controller or PLC SIL 3 Time before dangerous failure: MTTFd = 100 years Maximum detection activation distance: 2 mm Holding force: up to 936 N (ref. version + OX-R) or up to 820 N (ref. version + OX-E) Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Reset: automatic or controlled (ref. + OP) Housing mount: 4 tamper-proof M6 screws (optional ref: BH6) Handle attachment: 2 M8 screws Mounting position: 1 Casing material: 316L stainless steel mirror polished (OX version) Suction cup material: Magnetic INOX (ref. + OX) Electrical Connection: 50cm PUR cord with M12 connector Water resistance: IP 67/68 Temperature: -25°C to +50°C (thermal protection for suction cups in case of overheating due to a persistent command) Marking: laser engraving with mechanically punched serial number for permanent traceability
Request for a quoteCOMITRONIC BTI
France
No power or under-voltage locking on machine casings Machine protection closing control for harsh environments 100% stainless steel version available Level of performance with AWAX controller: up to PL = e Safety category: up to 4 with AWAX controller or PLC SIL 3 Time before dangerous failure: MTTFd = 100 years Maximum detection activation distance: 2 mm Holding force: up to 580 N Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA Detection encoding: mono-code inviolable Indicator: LED Reset: automatic or controlled (ref. + OP) Attachment: 4 M4 screws (inviolable on new generation and optional ref.: BH4) Mounting position: 1 Casing material: INOX316L mirror polished (OX version) or POLYCARBONATE (PL version) Suction cup material: INOX (SM1 + OX) or steel (SM1 + PL-AC) Electrical connection: the M12 metal base will be replaced with a 50cm PUR cord with an M12 connector on the new generation Water resistance: IP 67/68 Temperature: -25°C to +50°C. Marking: laser engraving with mechanically punched serial number for permanent traceability (OX version) or screen printed serial number for traceability (PL version)
Request for a quoteCOMITRONIC BTI
France
Compact 22.5 mm format Suitable for RDX8 or other sensor Removable terminals Cycle before dangerous failure: B10d = 2,000,000 at 2A Risk duration: 10 ms max Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts: 2 x NO 8A/250V + 2 x NF 8A/250V Diagnostics: 1x NO 400mA/60V max Indicators: 3 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -25°C to +70°C.
Request for a quoteCOMITRONIC BTI
France
Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X
Request for a quoteCOMITRONIC BTI
France
Contactless coded electronic sensor ATEX zone 0/20 (PL version) or 1/21 (OX version) Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking for PL version II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da Product used in combination with AWAX26XXL-EEX box ATEX marking for OX version II 2 GD Ex ia IIC T4 Gb Ex ia IIIC T135°C Db Product used in combination with AWAX26XXL-EEX box Machine Safety Level of performance with AWAX controller: up to PL = e Safety category: 4 with AWAX controller Time before dangerous failure: MTTFd = 277 years Max. activation distance: 10 mm, 4 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/12V redundant and 1 x PNP 15mA/12V contact Shock / vibrations: 30 G Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Total number of connectable sensors in series: 0 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 (PL version) or INOX 316L mirror polished (OX version) Electrical connection: 12m or more on request Water resistance: IP 67
Request for a quoteCOMITRONIC BTI
France
Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.
Request for a quoteManufacturer/ Producer
14 Rue Pierre Paul de Riquet
33610 Canéjan - France
SHENZHEN PROMOSTAR HARDWARE CO.,LTD
Germany
These are the parts made by brass, then after colorful plating, the products mainly used in electronic product field.
Request for a quoteSHENZHEN PROMOSTAR HARDWARE CO.,LTD
Germany
These are the E-cigarette shell which is machining by aluminum,then after special knurled,brown plating ,its nice appearance makes it very popular.
Request for a quotePEEKCHINA CO., LTD.
China
Manufacturing Process CNC Machining & Injection Molding PEEK performance Polyetheretherketone (PEEK) is a high-performance, engineering thermoplastic characterized by an unusual combination of properties. These properties range from high temperature performance to mechanical strength and excellent chemical resistance. Material Grade ARKPEEK-1000: 100%PEEK Produced from virgin polyetheretherketone resin and offers the highest toughness and impact resistance of all types. ARKPEEK-CF30: 30% Carbon Fiber + 70% PEEK Carbon fiber reinforcement lends the material a high level of rigidity and creep strength, high mechanical strength and heat conductivity values. ARKPEEK-GF30: 30% glass fiber + 70% PEEK Glass filled PEEK exhibits increased mechanical strength and high rigidity. ARKPEEK-MOD: 10% Carbon Fiber + 10% PTFE +10% Graphite high performance engineering plastic with product characteristics including excellent sliding and abrasion & wear resistance, high mechanical.
Request for a quotePEEKCHINA CO., LTD.
China
Material: Amorphous, Semi-crystalline and Mineral Filled Semi-crystalline. PEEK (polyetheretherketone) Film Provides: ● High Temperature Performance ● Excellent Tribological Properties ● Broad Chemical Resistance ● High-Strength & Toughness ● Electrical Stability & Radiation Resistance ● Low Smoke & Toxic Gas Emission ● High-Purity, extremely low extractables Appication: ● Micro speaker diaphragm, dome tweeter. ● Presslire exchanger and senior oliaphragin. ● Aerospace high-speed rail insulation and TAB heat insulation components. ● Thrust washers for micro motors, gaskets for automobiles. ● High-temperature resistant label, pressure sensitive tape substrate. ● Insulation layer of electric vehicle battery. ● Flexible film surface heater. ● Wire, cable, insulation and wrcop sheaths.