• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • atex

Results for

Atex - Import export

Service Provider

France

Sensor contactless technology, low simultaneity ATEX Zone 2 and 22 category 3GD No power Atex safety EN 60079-15 EN 61241-1 Machine Safety Level of performance with AWAX26XXL-EEX3 controller: up to PL = e in accordance with EN ISO 13849-1 Cycle before dangerous failure: B10d = 62,500 Max. activation distance: 17 mm, 5 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel Overcurrent: 500mA for 2s Shock resistance: 50 G. Vibrations: 30 G Detection encoding: mono-code Indicators: no Reset: automatic Total number of connectable sensors in series: 30 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 Marking: pad printing + serial no. for traceability Electrical connection: 3, 6, 12m cable Water resistance: IP 67 Temperature: -5°C to +80°C.

Request for a quote

France

Contactless coded electronic sensor ATEX zone 0/20 (PL version) or 1/21 (OX version) Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking for PL version II 1 GD Ex ia IIC T4 Ga Ex ia IIIC T135°C Da Product used in combination with AWAX26XXL-EEX box ATEX marking for OX version II 2 GD Ex ia IIC T4 Gb Ex ia IIIC T135°C Db Product used in combination with AWAX26XXL-EEX box Machine Safety Level of performance with AWAX controller: up to PL = e Safety category: 4 with AWAX controller Time before dangerous failure: MTTFd = 277 years Max. activation distance: 10 mm, 4 mm hysteresis Safety contacts/diagnostics: NO 2 x 50 mA/12V redundant and 1 x PNP 15mA/12V contact Shock / vibrations: 30 G Detection encoding: mono-code inviolable Indicator: LED indicates code recognition Reset: automatic Total number of connectable sensors in series: 0 Attachment: 4 tamper-proof M4 screws (optional ref: BH4) Mounting position: 2 (double wall brackets) Material: PA6 (PL version) or INOX 316L mirror polished (OX version) Electrical connection: 12m or more on request Water resistance: IP 67

Request for a quote

France

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X

Request for a quote

France

Compact 22.5 mm format Suitable for RDX8 or other sensor Removable terminals Cycle before dangerous failure: B10d = 2,000,000 at 2A Risk duration: 10 ms max Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts: 2 x NO 8A/250V + 2 x NF 8A/250V Diagnostics: 1x NO 400mA/60V max Indicators: 3 LEDs Reset: automatic Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -25°C to +70°C.

Request for a quote

United Kingdom

We manufacture all our offshore A60 service cabins in accordance with the highest industry standards (e.g. DNV 2.7-1, EN12079, DNV 2.7-2, DNV 2.7-3, ATEX, IEC 2nd NORSOK) including compliance with SOLAS/IMO regulatory requirements for fire protection. State-of-the-art safety monitoring systems are incorporated, where required, including integrated fire and gas, pressurisation and emergency shutdown systems suitable for applications up to Zone 1. They can be outfitted to perform any number of functions to suit your exact offshore project. Available from stock from our network of global bases. MWD Cabins, LWD Cabins, Laboratories, Leak Test Cabins, Work areas, Document Stores, Dark rooms, Local Equipment Rooms (LER), Telecom Rooms, Control Cabins, Dive Control, Cabin Internet room, IT Server room, Office Cabin Technicians Cabin, Gymnasium, Workover Cabin, Well Services.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business
Filters

Results for

Atex - Import export

Number of results

5 Products

Company type