• europages
  • >
  • COMPANIES - SUPPLIERS - SERVICE PROVIDERS
  • >
  • test rooms

Results for

Test rooms - Import export

Germany

Germany

Verified by Europages

E2 micro E-Chains® are very small, one-piece and two-piece (B07/B09) E-Chains® with a low weight and therefore ideal for highly dynamic applications. E2 micro E-Chains® are stable and available in many versions. igus® also offers numerous accessories and mounting options. "UPGrades" of the snap-open versions are available for many types; they are interchangeable among themselves and can thus be used as, among others, spare parts pack for new installation options. Other information Series 03 Inner height hi: 5 mm Inner widths Bi: 5 - 10 mm bending radii R: 10 - 28 mm Pitch: 10 mm E-Chain®, not-to-be-opened Series 04 Inner height hi: 7 mm Inner widths Bi: 7 - 30 mm bending radii R: 15 - 48 mm Pitch: 16,7 mm E-Chain®, not-to-be-opened Series 045 Inner height hi: 10,3 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 13 mm E-Chain®, not-to-be-opened Series 05 Inner height hi: 10 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, not-to-be-opened Series 06 Inner height hi: 10,5 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, not-to-be-opened Series 08 Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 25 - 48 mm Pitch: 20 mm E-Chain®, not-to-be-opened Series B07 Inner height hi: 10,3 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, snap-open along the outer radius Series B09 Inner height hi: 14,3 mm Inner widths Bi: 16 - 40 mm bending radii R: 28 - 48 mm Pitch: 20 mm E-Chain®, snap-open along the outer radius Series 074 Inner height hi: 10.9 mm Inner widths Bi: 10 - 40 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, snap-open along the inner radius Series 094 Inner height hi: 14,3 mm Inner widths Bi: 10 - 40 mm bending radii R: 28 - 48 mm Pitch: 20 mm E-Chain®, snap-open along the inner radius Series E2.10, openable along the outside Inner height hi: 10 mm Inner widths Bi: 6 - 50 mm bending radii R: 10 - 38 mm Pitch: 20 mm e-chain®, snap-open outside Series E2i. 10, openable on the inside Inner height hi: 10 mm Inner widths Bi: 6 - 50 mm bending radii R: 10 - 38 mm Pitch: 20 mm e-chain®, snap-open inside Serie E2C. 10, closed Inner height hi: 10 mm Inner widths Bi: 6 - 50 mm bending radii R: 10 - 38 mm Pitch: 20 mm e-chain®, closed Series E2.15, openable along the outside Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 28 - 48 mm Pitch: 20 mm e-chain®, snap-open outside Series E2i. 15, openable on the inside Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 28 - 48 mm Pitch: 20 mm e-chain®, snap-open inside Serie E2C. 15, closed Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 28 - 75 mm Pitch: 20 mm e-chain®, closed iF-Design-Award for E2 micro Series 05 Clean room test on request Special design: Electrically conductive ESD/Atex versions on request UL94-V0 classification for Series 03 and Series 14 (more on request) 42 dB(A) determined at the igus® laboratory, v = 1.0 m/s unsupported, Series 06.10.038.0 E2 micro E-Chains® are very small, one-piece and two-piece (B07/B09) E-Chains® with a low weight and therefore ideal for highly dynamic applications. E2 micro E-Chains® are stable and available in many versions. igus® also offers numerous accessories and mounting options. "UPGrades" of the snap-open versions are available for many types; they are interchangeable among themselves and can thus be used as, among others, spare parts pack for new installation options. Series 03 Inner height hi: 5 mm Inner widths Bi: 5 - 10 mm bending radii R: 10 - 28 mm Pitch: 10 mm E-Chain®, not-to-be-opened Series 04 Inner height hi: 7 mm Inner widths Bi: 7 - 30 mm bending radii R: 15 - 48 mm Pitch: 16,7 mm E-Chain®, not-to-be-opened Series 045 Inner height hi: 10,3 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 13 mm E-Chain®, not-to-be-opened Series 05 Inner height hi: 10 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, not-to-be-opened Series 06 Inner height hi: 10,5 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, not-to-be-opened Series 08 Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 25 - 48 mm Pitch: 20 mm E-Chain®, not-to-be-opened Series B07 Inner height hi: 10,3 mm Inner widths Bi: 6 - 64 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, snap-open along the outer radius Series B09 Inner height hi: 14,3 mm Inner widths Bi: 16 - 40 mm bending radii R: 28 - 48 mm Pitch: 20 mm E-Chain®, snap-open along the outer radius Series 074 Inner height hi: 10.9 mm Inner widths Bi: 10 - 40 mm bending radii R: 18 - 38 mm Pitch: 20 mm E-Chain®, snap-open along the inner radius Series 094 Inner height hi: 14,3 mm Inner widths Bi: 10 - 40 mm bending radii R: 28 - 48 mm Pitch: 20 mm E-Chain®, snap-open along the inner radius Series E2.10, openable along the outside Inner height hi: 10 mm Inner widths Bi: 6 - 50 mm bending radii R: 10 - 38 mm Pitch: 20 mm e-chain®, snap-open outside Series E2i. 10, openable on the inside Inner height hi: 10 mm Inner widths Bi: 6 - 50 mm bending radii R: 10 - 38 mm Pitch: 20 mm e-chain®, snap-open inside Serie E2C. 10, closed Inner height hi: 10 mm Inner widths Bi: 6 - 50 mm bending radii R: 10 - 38 mm Pitch: 20 mm e-chain®, closed Series E2.15, openable along the outside Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 28 - 48 mm Pitch: 20 mm e-chain®, snap-open outside Series E2i. 15, openable on the inside Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 28 - 48 mm Pitch: 20 mm e-chain®, snap-open inside Serie E2C. 15, closed Inner height hi: 15 mm Inner widths Bi: 10 - 50 mm bending radii R: 28 - 75 mm Pitch: 20 mm e-chain®, closed E-Chain® selection aids You can find the right E-Chain® quickly by entering concrete parameters and with the aid of a comparison table. Selection aids Installation instructions Joining and separating of the E2 micro E-Chain®. Assembly Instructions Application examples Applications in various industrial sectors. E2 micro For restricted spaces One and two-piece E-Chains®, from 5 mm inner height High torsion resistance Smallest inner heights and bending radii Mounting brackets with strain relief optional Small pitch for silent operation Cable-friendly interior Low weight Large pins for a long service life Favorable internal/external dimensions ratio B07/B09 in two parts - Can be folded out in outer radius due to integral hinges Typical industrial sectors and applications General construction machinery Models (micro E-Chain®), Automatic doors Vehicles Measuring machines Electronics Handling systems Pick and place robot iF-Design-Award for E2 micro Series 05 Clean room test on request Special design: Electrically conductive ESD/Atex versions on request UL94-V0 classification for Series 03 and Series 14 (more on request) 42 dB(A) determined at the igus® laboratory, v = 1.0 m/s unsupported, Series 06.10.038.0

Request for a quote

Germany

Verified by Europages

We have been manufacturing UP machines / components and beam delivery systems for over 20 years.Benefit from our experience and let us do your demanding assembly or adjustment work.Assembly / adjustment of optical systemsAssembly / adjustment of mechanical precision systems.cleaning.Clean room assembly.Functional test.

Request for a quote

Germany

With our HPT heat pump test bench you can simulate humidity as well as temperature. The test stand is used for functional testing of air-to-water heat pumps according to DIN EN 14511. Current test systems on the market, which are used to test e.g. air-to-water heat pumps, are climatic chambers with a cooling, heating and humidification unit fixed to the roof. The disadvantage of this concept is that it is not possible to set a homogeneous temperature and humidity distribution in the cube-shaped room. Based on test engineering concepts in the automotive industry, EP-E developed a concept in which the air flows in a closed loop (loop design). The HPT heat pump test stand is a closed-loop test stand for functional testing of air-to-water heat pumps according to DIN EN 14511. The advantageous closed-loop design uses an insulated chamber with conditioning units for temperature and humidity outside the chamber.

Request for a quote

Germany

The universal testing machine inspekt offers high-class mechanic precision, frame stiffness and modern control electronics. Customers also profit from the convincing cost/performance ratio. The top-quality, rugged machines can be used for almost any testing task. The size of the test room of the individual machines can be customized. It is also possible to add one or more test room. In combination with our user-friendly testing software LabMaster, standard-based and customer-specific tests can be easily implemented. Testing machine, testing software and our extensive range of accessories such as specimen grips and testing tools, extensometers or temperature control devices are optimally matched to each other and offer the ideal testing system for a wide variety of testing applications (tensile tests, compression tests, bending tests, peel tests,...). - Solid construction for highest measuring and control precision - Flexible design for versatile applications

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business