Flow monitoring Flow monitoring is a procedure that demands a reliable and reproducible surveillance of limit values and flow patterns. Flow sensors detect critical deviations of the flow rate of liquid and gaseous media. Typical areas of application are the monitoring of cooling circuits in welding applications for example, protection against dry running of pumps, as well as the flow monitoring in air ducts and air conditioning equipment. Because of the calorimetric mode the media temperature is also monitored. Flow rate measurement In addition to reproducibility, flow-rate measurement demands a defined degree of accuracy. The flow meters continuously and accurately measure a defined volume of a fluid per unit of time and are suitable for applications where qualitatively consistent process results and a steady supply of fluids is essential. We offer flow meters with calorimetric, magnetic-inductive and Vortex measurement principle for various areas of application.

Request for a quote

Germany

Verified by Europages

CSN® Explosionproof screw plug or flanged immersion heaters ( Ex ) are perfectly suited for direct heating of liquids or gas / air mixtures in hazardous areas. The devices are available with attached or integrated temperature monitoring systems. For these heaters various high quality stainless steel grades are available. The electical immersion heater type 94./..EEs….T.(.) is designed for the heating of liquids and quit gasair mixtures in the zone 1 and zone 2. The standars elements, mentioned in this list are suitable for DGRL (code 97/23/EG) Art. 3 Para. 3. The elements can be suited (on request) to other uses requiring another classification according to DGRL.

Request for a quote

Germany

Verified by Europages

CSN® screwin heating units are particularly suitable for the direct heating of liquids, air and gases. In relation to the process, we provide you with screwin or tank heating units with tubular heating elements made of stainless steel which we adjust to the respective application situation and the medium to be heated in consultation with you. The surface loadings, a very critical design feature for the longterm durability of the elements, are calculated for their specific application. For exact temperature monitoring, the screwin heating units can be manufactured with various controllers and / or limiters, as well as PT100 sensors or sheath thermocouples. Our team also looks forward to standing by your side if you need heating solutions which cannot be covered with socalled standard solutions. We are happy to develop processcustomised solutions in close consultation with you. We look forward to your task.

Request for a quote

Germany

Verified by Europages

CSN ® Explosion proof cartridge heaters as direct heaters for liquids or gases in hazardous environment. These units are equipped with a heating bundle or a replaceable ceramic heating element. For temperature control these heaters are available with an integrated temperature monitoring system. These devices are available in various material grades. The electric cartridge heating element type 93./..EEx….T.(.) is designed for the heating of liquids in the zone 1 and zone 2. The standars elements, mentioned in this list are suitable for DGRL (code 2014/68/EU) Art. 4, Para. 3. The elements can be suited (on request) to other uses requiring another classification according to DGRL Further information about our CSN® ExCartridge Heater

Request for a quote

Germany

Verified by Europages

Just as innovative as the design of the AirgoClean® 140 E/145 E is its intelligent air purification system for permanent control and improvement of the room air quality. Protect your health and the health of the people around you with HEPA-filtered air that is 99.97 % free from harmful suspended particles. The AirgoClean® 140 E/145 E removes pathogenic viruses such as SARS-CoV-2 or the influenza virus, bacteria, fine dust, house dust, pollen, dust mite residues, mould spores or allergens from the room air just as reliably as cigarette smoke, smog and other unpleasant odours. Fully automatically, thanks to state-of-the-art air quality sensors. The air quality sensors of the AirgoClean® 140 E/145 E continuously monitor the room temperature and humidity as well as the air quality and microparticle load of the room air in order to clean it with an intelligently controlled air cleaning performance.

Request for a quote

Do you sell or make similar products?

Sign up to europages and have your products listed

Add my business

Germany

Verified by Europages

The integrat 80 is used for the modular temperature control with water up to 140°C in the basic version with up to six temperature control circuits to be operated completely independently of each other. The basic version can be expanded with extension columns and up to 24 temperature control modules. As an option, the temperature control circuits can be extended with the 4-way distributor vtc with flow and temperature measurement. Thus, a maximum of 96 temperature control circuits can be monitored with the vtc 4-way distribution system. In conjunction with the standard heating control system used as standard, a homogeneous temperature profile on the mould cavity surface is achieved in an extremely energy-efficient manner, as well as with constant cooling by using a motor valve. As an option, the pumps can also be operated with frequency control unit. This improves the procedural results and contributes to energy savings.

Request for a quote

Germany

Verified by Europages

MULTI-ZONE TEMPERATURE CONTROL- AND MONITORING SYSTEM WITH NON-CONTACT FLOW MEASUREMENT. Due to the design, dimensioning and selection of the used components, enersave temperature control systems are the most efficient systems on the market with the highest flow rates at operating point. By using the frequency inverter, the already high basic efficiency is optimized and the pump characteristic curve will be optimally adapted to the respective operating conditions. The flow measurement of the individual temperature zones is carried out using noncontact measurement technology according to the ultrasonic principle.

Request for a quote

Germany

For head or field installation Feed via current loop Temperature compensation Measurement/monitoring to USP<645>

Request for a quote

Germany

Filltech's most advanced pumping technology: High-end CO 2/N 2O pump designed for automatic redundancy and fail-over Highlights Intelligent interoperability with any Filltech filling station Optimized energy consumption Complete plug &amp; Play system ready for instant connection Safe operation through intelligent monitoring: pressure, temperature, leakage Low noise emission Application ready: filling, dozing, transfer, supply Joint pumps for flow-rates up to 6 tons Remote operations: Monitoring, remote control, power control Technical Data Capacity: 400 - 1500 kg/h, 6-25 lpm, 1.7 -6.6 gpm Power supply: 3 x 400V / 50 Hz, opt 120 / 208V, opt. 277 / 480V/60Hz, 3-phase Power consumption: 1.5 to + 4 kW/h (dep. on pump size) Dimensions (LxWxH): 900 x 900 x 1670 mm / 35 x 35 x 66 in. Pump Triplex plunger pump NP 25/50 – 25/70 Motor: Belt drive Construction characteristics CO 2 supply: liquid from tank system Ring- or stub lines Automatic start cycle Pressure supply needed for valve: 8 b

Request for a quote

Germany

Wireless fire detector with temperature sensor that monitors security in the room twenty four hours a day and immediately notifies of smoke and sharp jumps in temperature.

Request for a quote