Wire WT | Pt1000 - Wire resistance thermometer
Wire WT | Pt1000 - Wire resistance thermometerWire WT | Pt1000 - Wire resistance thermometer

Wire WT | Pt1000 - Wire resistance thermometer

Inline resistance thermometer Pt1000 Measurement range:-50 °C to +260 °C Electrical resistance:Pt1000 Tolerance:B / A or AA as per DIN IEC 751 Conductor:PTFE-Teflon Conductor guide:open Conductor:Strand, Cuvs, AWG 24F, 2 x 0.22 mm² (19 x 0.127 mm) Strand colour:white, red Wire length:500–5,000 mm Type of connection:Selection R ISO / 1000VAC:>200 Mohm
Similar products
1/15
Panel Standard Insert Flanged Bracket Mounting (PSIFB) - Panel Standard Insert
Panel Standard Insert Flanged Bracket Mounting (PSIFB) - Panel Standard Insert
Application: Panel insert for thermocouple and RTD citcuits. Mounting by means of a stainless steel bracket and two screws. Mechanical design: • Hous...
DE-51789 Lindlar
THK – Thermocouple Amplifier - Displays and transmitters
THK – Thermocouple Amplifier - Displays and transmitters
Compatible with any thermocouple probe type K fitted with a miniature plug. The thermocouple probe wires must be isolated from supply ground. THK 200...
DE-51789 Lindlar
Sheathing | without wire | Pt1000 - Sheathing resistance thermometer
Sheathing | without wire | Pt1000 - Sheathing resistance thermometer
Sheathing resistance thermometer Pt1000 without wire with flexible sheathing design Measurement range:-50 °C to +550 °C Electrical resistance:Pt1000 ...
DE-51789 Lindlar
Screw-in W-10136 | Fibreglass | Ni120 - Sheating tube resistance thermometer
Screw-in W-10136 | Fibreglass | Ni120 - Sheating tube resistance thermometer
Screw-in resistance thermometer Ni120 Measurement range:-50 °C to +450 °C Electrical resistance:Ni120 Probe Ø:2.5 x 7 mm Installation length:13 mm Th...
DE-51789 Lindlar
TEX-24F-Cuvn | 25 m - Teflon
TEX-24F-Cuvn | 25 m - Teflon
TEX-24F-Cuvn | 25 m - Teflon Length:25 m Conductor:strand, Cuvs, AWG 24F, 0.22 mm² (19 x 0.127 mm) Conductor insulation:PTFE Teflon Conductor guide:s...
DE-51789 Lindlar
Screw-type TC | Silicone | Type K | - Screw-in thermocouple
Screw-type TC | Silicone | Type K | - Screw-in thermocouple
Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement...
DE-51789 Lindlar
Sheathing | without wire | Ni120 - Sheathing resistance thermometer
Sheathing | without wire | Ni120 - Sheathing resistance thermometer
Sheathing resistance thermometer Ni120 without wire with flexible sheathing design Measurement range:-50 °C to +550 °C Electrical resistance:Ni120 Ci...
DE-51789 Lindlar
Plug-in thermocouple | Teflon | NTC 10 kOhm - Plug-in resistance thermometer
Plug-in thermocouple | Teflon | NTC 10 kOhm - Plug-in resistance thermometer
Plug-in resistance thermometer NTC 10 kOhm Measurement range:-50 °C to +260 °C Electrical resistance:NTC 10 kOhm Circuit type:2, 3 or 4-wire techniqu...
DE-51789 Lindlar
TEXTW-2 x 24F-Cuvs | 50 m - Teflon
TEXTW-2 x 24F-Cuvs | 50 m - Teflon
TEXTW-2 x 24F-Cuvs | 50 m - Teflon Length:50 m Conductor:strand, Cuvs, AWG 24F, 2 x 0.22 mm² (19 x 0.127 mm) Conductor insulation:PTFE Teflon Conduct...
DE-51789 Lindlar
Quantrol – Compact controller LC100 - Displays
Quantrol – Compact controller LC100 - Displays
Format 48 x 48 mm Two/three step, continuous controller Sensor monitoring Up to 5 outputs 1 Analogue input (universal) 1 Binary input 1 Relay output (...
DE-51789 Lindlar
TEX/CUTEXTW-24F-KK-IEC | 100 m - Teflon
TEX/CUTEXTW-24F-KK-IEC | 100 m - Teflon
TEX/CUTEXTW-24F-KK-IEC | 100 m - Teflon Length:100 m Thermocouple combination:NiCr-Ni Type “K” Limiting deviation:Class 1, DIN IEC 584 Part 2, +/- 1.
DE-51789 Lindlar
Sheathing tube | Teflon | Pt1000 - Sheating tube resistance thermometer
Sheathing tube | Teflon | Pt1000 - Sheating tube resistance thermometer
Sheathing tube resistance thermometer Pt1000 Measurement range:-50 °C to +260 °C Electrical resistance:Pt1000 Tolerance:B / A or AA as per DIN IEC 75...
DE-51789 Lindlar
Coupling jack Miniature | Locking (CMLJ) - Connector Miniature
Coupling jack Miniature | Locking (CMLJ) - Connector Miniature
Use: Connectors for thermocouples and resistance thermometer measurement circuits. Suitable for measurement with small wires and mineral-insulated met...
DE-51789 Lindlar
KFD-24-KK-IEC | 50 m - Kapton
KFD-24-KK-IEC | 50 m - Kapton
KFD-24-KK-IEC | 50 m - Kapton Length:50 m Thermocouple combination:NiCr-Ni Type “K” Limiting deviation:Class 1, DIN IEC 584 Part 2, +/- 1.5 °C or 0.0...
DE-51789 Lindlar
Sheathing tube | Fibreglass | Type K - Sheathing-tube thermocouples
Sheathing tube | Fibreglass | Type K - Sheathing-tube thermocouples
Sheathing thermocouples can be used anywhere due to their ruggedness and small design. Whether in industry, development or in the lab. The measurement...
DE-51789 Lindlar

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store