Germany, Nordhausen
119km
... include: ISO 14644 ASTM G122-96 ASTM D6361 SAE AMS 0302 The PPM leak test stand is able to be programed to the customers requirement. The powerful in house built software enables exact design of pressure curves, such as holding times and exact pressure increase over time. It is an ideal solution for any sorts of plastic components. This exemplarily displayed test bench can utilize air or nitrogen as a test medium. Please get in touch about any other test mediums. In addition the PPM test benches can perform tests of multiple test units at a time.
...In addition to the usual ICT/FCT procedures, we can also specifically verify each individual manufacturing step depending on the requirements. Efficient testing strategies and final functional tests are an integral part of our quality management. In our testing laboratory, we can conduct automated, static, and cyclic environmental simulations for you, ranging from temperature shock air and temperature shock liquid tests to storage temperature tests and humidity tests. Based on the future operating environment, we compile a suitable qualification program for each product.
Germany, Magdeburg
211km
... you with regard to your testing tasks and, together with you, transfer the entire testing process into a specification sheet. OUR OPPORTUNITIES 2-chamber system air-air Test chamber volume up to 130 liters Temperature range hot chamber 50°C to 200°C Temperature range cold chamber -80°C to -100°C Change between chambers <15 seconds Maximum test material weight 25 kg State monitoring of the test specimens during the test...
...A good way to visually represent air distribution in a room/area is by using smoke cartridges. This smoke enters the room to be tested through the supply air outlets. Upon request, the smoke tests can be recorded with a digital video camera and included in the system documentation. Please contact us.
... HIGH SAVINGS POTENTIAL. Teddington air curtain systems are pioneering when it comes to effectiveness and reliability under demanding conditions. Various tests, including those in our testing facilities, impressively demonstrate the efficiency of our devices with the patented CONVERGO® pressure chamber nozzle system.
Germany, Linsengericht
73km
... and Control of Chamber Temperature Direct Setting and Control of Relative Humidity Display of Diagnostic Message Storage for 10 user-defined tests Multilingual User Interface Non-aging filter systems for ISO 105-B02 and AATCC TM16 On-rack XENOSENSIV® for measuring and controlling irradiance (in W/m²) and Black Standard Temperature on sample level Selectable temperature control either by Chamber...
Germany, Erkrath
234km
... surfaces get not damaged. The blasting process is suitable for the removal of all solid, exposed residues, especially on metallic surfaces of production tools and high-quality machine parts. Blasting granulate and blasting pressure are adapted to the respective application. With the pressure blasting process you can clean extruder and injection moulding screws, blowing heads, moulds and profile tools much faster and more gently than with conventional cleaning methods. In extensive tests with your own workpieces you can convince yourself of the economic efficiency of our system.
Germany, Langenfeld (rheinland)
228km
... bar to 8 bar bar Rail sizes:15 mm and 25 mm Bosch Rexroth Clamping cycles:1,000,000 Mounting:Vertical Effective direction:Z-axes toward gravity Material:Tool steel; Brake components: Steel Pneumatic medium:Dried, filtered air Operating temperature range:0 °C to 60 °C Application field:Z-axes, Vertical conveyor systems, Jacking applications...
Germany, Köln
223km
... XPR 3+ provides far superior product protection compared to periodic rate of rise tests. DRIVNG PROFITABILITY BY MAXIMIZING TOOL UPTIME The Transpector XPR 3+ RGA is a field proven quadruple and dual ion source sensor for sputtering pressure range applications. No pressure conversion equipment is required, long lifetime components, and the ability to rapidly detect and diagnose problems combine to maximize tool availability, product throughput and yield. The sensor can be operated continuously from high vacuum to 20 mTorr, without the need for pumps. The Transpector XPR 3+ dual ion...
Germany, Wimsheim
207km
... or influence the operation of the air-bag of the vehicle-own steering wheel with the actuator mounted. With the drive disabled, the vehicle can be driven by the driver. Test procedures can be created and executed in stand-alone operation. The system also can be integrated into a host automation system. Different configurations and options such as additional actuators (throttle, brake, clutch shift), additional operation modes and different integration interfaces are available. The steering system also cam be linked to the Autopilot System for fully automated driving of...
Germany, Donauwörth
208km
...Features: Fans of the ARMO-A series are fire-resistant fresh air and smoke extraction fans. All models are certified according to EN-12101-3 and CE, and they meet fire protection tests (2 hours at 300-400°C). The Armo-A series offers 2-, 4-, and 6-pole motors, which have an IP55 protection class and insulation class H. The fire-resistant housing is made of solid galvanized steel sheet and is...
Germany, Lauterbach
50km
...among other applications. Additionally, we supply galvanized or coated versions manufactured in small and large series, in pre-assembled units that meet specific requirements for tightness, air guidance, material, and aesthetics. Simply ask us for relevant laboratory tests or performance certificates.
Germany, Reilingen
174km
...Types of construction: - Brake dynamometer with eddy current brake (air or water cooled) - Low inertia hydrostatic dynamometer - Dynamometer with water vortex brakes - Regenerative dynamometer, 4-Q mode (low inertia) Areas of application: research, development, quality assurance, and training.
...³ Temperature range: -70 to +180°C II +50 to +300°C Humidity/climate range: 5 to 98% relative humidity Temperature change rate: Cooling: 2 to 15 K/min II Heating: 2 to 15 K/min Control/regulator: C-Touch screen Digital display of set and actual values, 3 analog channels visible simultaneously, graphical curve progressions Options: Pipe penetrations Ground-level loading Access ramps Machine unit next to or on cell ceiling External air-cooled condenser We would be happy to advise you personally and equip your walk-in test chamber according to your requirements.
Germany, Springe-Eldagsen
190km
...To conduct airtightness tests in large buildings, simply combine several BlowerDoor fans (BlowerDoor MultipleFan): With up to three fans per door opening, Germany’s leading measuring system for airtightness easily masters even large air-flow rates! The BlowerDoor MultipleFan system consists of three BlowerDoor fans and two digital DG-1000 pressure gauges, and was developed for airtightness...
Germany, Ebhausen
238km
...Vacuum systems, vacuum degassing, batteries, accumulators, medical components, process control - degassing in a vacuum Using vacuum degassing, unpleasant taste or odor nuisances can be removed, making them taste-neutral. Altitude simulation For air transport, it is essential to conduct tests and simulations at a pressure < 800 mbar, as pressure equalization occurs in cargo holds, but not all...
Germany, Laatzen
196km
... resistance, air tightness, and weather resistance according to DIN 18542. Hannoband-BG1-M For particularly demanding and larger joint widths, the use of Hannoband-BG1-M with HANNO membrane technology is recommended.
Germany, Steinenbronn
217km
... - Pressure dependency testing - Temperature behavior investigation - Repeatability measurement - Measurement capability determination (cgm, cgk) ...with the measured variables: - Flow - Pressure - Temperature - Humidity - Current - Voltage - Force - Distance - Medium: Air – other gases upon request!
Germany, Hartmannsdorf
196km
...We test products for their functionality under various environmental influences such as temperature, climate, air pressure, water, dust, as well as mechanical stresses. We simulate a variety of predictable environmental conditions in our laboratories and check whether your product can withstand these and will function reliably in its later application environment. Lifetime tests replicate the...
Germany, Freiberg
233km
...Visual tests in the laboratory and semi-technical scale Visual tests on a semi-technical scale can be conducted with us using an ATP 200 air classifier from Hosokawa Alpine. This classifier excels particularly in the fine particle range and allows for separation particle sizes down to approximately < 5 μm. A closed-loop system with our model mill is also feasible. In this setup, the coarse...
Germany, Bad Homburg
109km
... competitive price, have convinced our customers since the filter's introduction. Through continuous improvements, Infastaub optimizes and expands the functionality of the AJB, such as its pressure shock-resistant design up to 1.0 bar overpressure, which has been demonstrated in explosion tests. A special version for low temperatures down to -40 °C is also available, as well as a version for food applications, where all product-contacting components are approved according to Regulation EU 1935/2005 and EU 10/2011.
Germany, Althengstett
219km
... as ABS and PVC, polyester, Styrofoam, wood, felt, leather, fabrics, textiles, as well as metals like aluminum, steel, etc. 3M™ Fast Tack 1000NF contains no volatile organic compounds (VOCs) according to tests following EPA Method 24. Application: Bonding upholstery foam to furniture and vehicles, office partitions, securing insulation materials in vehicles, heating systems, ventilation, air conditioning, and appliances. Size: 18.93-liter bucket...
Germany, Neuenrade
180km
...Tool No.: 1583/292 Operating Weight: 47.11 kg Raw Weight: 44.91 kg Diameter: 719 mm Alloy: AIZn10Si8MgK This top plate is used in an air suspension system employed by the railway. High demands are placed on the mechanical properties as well as the casting structure. These properties are verified through tests (such as X-ray, crack testing, etc.) in an accredited testing laboratory. This casting...
Germany, Remscheid
215km
...drinking water pipes with air according to DIN EN 806-4 and ZVSHK guidelines, differential pressure tests up to 1 bar, testing of wastewater pipes according to EN1610, ALL no problem. Documentation via IR interface to thermal printer on document-compliant long-term stable thermal paper, detailed reports in DIN A4 format or as PDF reports via PC software.
Germany, Babenhausen
102km
... process and the simultaneous introduction of air into the floc structure are crucial for the function and performance of the flotation systems. Specific preliminary tests with the respective wastewaters concerning the later flotation system and its sizing are essential. For this purpose, ALMAWATECH has its own technical center available for pilot tests. This allows for precise determination of flocculation and exact calibration of the flotation systems.
Germany, Niederzissen
201km
... installed in your vehicle. Unlike many providers, our performance adjustment is exclusively developed through extensive cycle tests. Due to the potential for manipulation on stationary test benches, our cycle tests are conducted solely in real traffic and/or on closed or designated tracks.
Germany, Obersontheim
163km
...Airflow blower with homogeneous air distribution according to WLTP, GTR15, and USS §1066. Electric height adjustment, flaps, and telescopic extensions. The airflow blower compensates for the lack of airflow during performance tests and driving simulations with motor vehicles on roller test benches. The generated airflow is directed, for example, through a low-lying, wide outlet channel...
Germany, Braunschweig
196km
... tests","D x L":"D x L: 246 x 722","suitable accessories available":"suitable accessories available","OEM quality":"OEM quality","Pressure":"Pressure: 12.5","Examination according to R34":"Examination according to R34","According to customer requirements":"According to customer requirements"}...
Germany, Rimbach
137km
... classified in accordance with EN 13501-3 based on conducted fire protection tests (EN 1366-2). In Germany, approval from the Deutsches Institut für Bautechnik (DIBt) is required. Their use is regulated in the federal states by the legal introduction of the Model Ventilation Systems Directive (M-LüAR). Fire protection dampers must be inspected by a qualified person at least every 12 months; we would be happy to take care of that for you. Get a quote today.
Germany, Taunusstein
140km
...Leak tests can be performed using air, water, or vacuum. This technique is employed when proof of the tightness of a pipeline needs to be provided. In this process, the pipeline is completely or sequentially sealed with closure balloons. Afterwards, the sealed pipe section is subjected to air pressure, for example. A special computer program monitors the pressure trend according to specified...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play