Germany, Apolda
113km
... side. Installation Time 10 m2 / man-hour (experienced installation personnel) Components Glass-glass solar modules with SSG bonded backrails and mechanical support Horizontal rail, sliding safety Vertical construction as well as brackets/spacer screws are often provided by the construction site. If necessary, these will be part of the package.
Germany, Schwerin
235km
... ® script language protocol and an extended command set, syringe pump programs can be processed. Due to the interface compatibility, syringe pumps can easily be replaced. The Micro Dispense Module is characterized by its modular design with optional modules, such as shiftable in- and outlet, optional pump size, filter and flow sensor. The core component is a micro annular gear pump, a robust and...
Germany, Berlin
112km
... Alarm Output Visualization on PC Multilingual Software Playback of Stored Thermal Images as 'Video' Automatic Temperature Analysis in Self-Defined Sectors Integrated OPC Server for Remote Control of the System Analog/Digital Output Modules Optical Resolution: Up to 200:1 (90% Energy) Measurement Temperature Range: 20 – 1,200 °C Field of View: 90° Measurement Points Per Line: Up to 1024 Line Frequency: Up to 150 Hz Ambient Temperature: 0 – 50 °C, with Water Cooling up to 180 °C Interfaces: Ethernet TCP/IP (100 Mbit/s), OPC, DDE, Analog/Digital Output, RS485...
...Multi-axis servo amplifier, controls up to eight axes, supply voltage 60 VDC, CANopen interface, slot for custom modules (e.g., additional fieldbus interfaces, external measurement system)...
Germany, Marksuhl
195km
...contactless and Dual Interface IC modules can be executed with the highest performance and yield by processing of up to 128 modules in parallel. In addition to basic test and parameter test, software is also available for chip module initialisation, personalisation, and OS loading. Integration of SAM, HSM, or similar modules can be realised easily. Using high-end reader technology from Smartware or Micropross, this automatic IC module test handler offers unmatched performance for the complete production test of smart card and RFID modules. Flexible reel to reel system for high-speed test,...
... connected PC workstation. For example, the windows are operated electrically. Each employee can conveniently configure their environmental conditions in their workspace. We primarily focus on applications based on KNX (ISO/IEC 14543) and SMI (Standard Motor Interface) standards.
... the measurement range from 100 mHz to 10 MHz (extendable to 40 or 100 MHz) it covers a dynamic range of 300dB (mOhm…TOhm) with a base precision of 0.01%. Add a multiplexer and realize multichannel setups or ask us for custom modifications or OEM modules.
Matching products
ISX-3
ISX-3
Other products
MEArack
MEArack
Germany, Berlin
95km
... Dimensions: 400/450/500 (diameter) + pipe suspension Weight: 2.5 - 3.0 kg Application: Pendant light Interface: Ceiling hook Material: Aluminum and V2A and steel pipe Lamp glass: NPE - opal Protection class: Class I Protection rating: IP 4X Fitting: LED modules LED light sources Conventional light sources Coating: according to RAL or DB also powder coating Power reduction: on request Ready for connection: for 230V, 50Hz...
Germany, Bamberg
236km
...RST® MICRO as the optimal interface between LED modules and voltage or current sources Rated voltage: 250/400 V Rated current: 8 A Number of poles: 2-3 Protection class: IP66/68 (3m; 2h)/69; longitudinal tightness optional...
Germany, Hohen Neuendorf Ot Bergfelde
119km
...various measurement ranges from 25 mbar to 700 bar two different accuracy classes up to 0.01% of the measurement range end value single or dual range configuration (one or two pressure measurement ranges) 25 pressure units selectable large display with backlighting, menu-driven interface robust and weather-resistant compact, easy to use, lightweight easy one-handed operation secure grip, shock-resistant, protected by elastomer external IDOS pressure modules for range extension can be connected programmable leak test...
Germany, Hannover
222km
...Fast and reliable connection of PROFINET-IO and CAN, with data buffer - CAN PLC connection, e.g., to SIEMENS SIMATIC S7-300 or S7-400 - Coupling of CANopen® modules (according to CiA® specification CiA 301) or CAN Layer-2 modules (according to ISO 11898-1) - No limitation on the number of CAN participants imposed by the module - The gateway operates as a PROFINET-IO device with a maximum of 256 data bytes per input and output on the PROFINET bus - High-speed CAN interface according to ISO 11898-2 - 100BASE-TX PROFINET interface...
Germany, Geisa
221km
... understanding. A separate connection module is provided for each door. This includes the RS485 reader interface, the relay for the door opener, and a monitored input for a door contact. The KYO Cenloc from Datafox can be expanded later, and thanks to plug-in modules, this can be done by the user themselves. Modules can be easily replaced on-site in case of damage. The KYO Cenloc is available in three variants: "Rack" for server cabinets, "Wall" for wall mounting, and as a "Kit" for custom setups.
Germany, Hanover
222km
... speed (ISO 11898-2) compatible interface allows a maximum data-transfer rate of 1 Mbit/s. The 100 BASE-TX PROFINET IO interface is compatible to IEEE802.3 and runs at 100 Mbit/s. The gateway is designed according to PROFIBUS International Document TC2-09-0002 (CANopen-Integration_7012 d07_Jul09). The PROFINET IO interface and the CAN interface are electrically isolated. The module can be configured via PROFINET IO configuration tool GSDML- Composer. The esd CAN tools (CANreal, CANplot, CANrepro, CANscript, COBview) can be used additionally for CAN diagnostics.
...Interfaces to ERP and material flow software enable automatic order generation and traceability of transports. Additionally, sensors and level monitoring can be used for order generation. There is also the option to manually enter orders via the web-based user interface. A flexible system. Expandable for applications and environments.
Germany, Berlin
100km
... protocol) 1 x Relay + 1 x Analog output or 2 x Relay modern OLED display that ensures high contrast and wide viewing angle programmable current and voltage transmission configuration of measurement device parameters via keyboard or in the eCon program (via USB) modular housing for DIN rail S according to DIN-EN 62208 (the measuring device has a width of 3 modules). Dimensions: 53 x 110 x 60 mm.
Germany, Bamberg
237km
... bank codes and postal codes: UniBank verifies bank connections based on account number / bank code, UniPost: Correct addresses reach their destination faster! The Universal Postal Code Module in Java checks the entry of German postal codes: In all program dialogs where postal codes need to be entered, the input is validated. Java modules for programming.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play