Type EGSL - DC Power Supplies
Type EGSL - DC Power Supplies

Type EGSL - DC Power Supplies

Type EGSL Category DC Power Supplies Design DC Power Supply (single-phase) Application As a DC power supply for general applications, e.g., for installation in devices, to supply control circuits in switchgear, distribution systems, machines, etc., with protective low voltage (SELV). Particularly suitable as a power supply for programmable logic controllers (PLC). Execution compact, finger-safe plastic housing (IP 20) the devices consist of a safety transformer according to EN 61558-2-6 as well as an electronic part with continuous short-circuit proof and over-temperature protected voltage regulators screw and snap-on mounting on DIN rail according to DIN EN 50022 connections to screw terminals according to VBG 4 with self-releasing terminal clamps printed performance data with circuit diagram the output voltage is indicated by a green LED Input Voltage: 230 V AC +/- 10% Switching Group: Ii0 Output Voltage: SELV DC 12 V or 24 V +/- 1% (adjustable) Protection Class: IP 20 Ambient Temperature: max. 60°C Output Current: 0.75 ... 1.5 A DC (temporarily overloadable) Frequency: 50-60Hz Ripple: < 20 mVss Emissions: EN 61000-6 -3/-4, (Class B) Immunity: EN 61000-6 -1/-2 Regulation: < 0.5 % Output Protection: none, as continuously short-circuit proof Output Protection Circuit: Freewheeling diode, Varistor Mounting Position: Cooling fins vertical Transformer: VDE 0570-2-6 / EN 61558-2-6 Safety: VDE 0805 / EN 60950 Installation: on DIN rail according to DIN EN 50022, lateral distance > 10 mm Protection Classes: II
Similar products
1/15
Type EGS - DC Power Supplies
Type EGS - DC Power Supplies
Type EGS Category DC Power Supplies Design Type DC Power Supply (Single-phase) Application For general use, e.g., to supply circuits in switchgear, ...
DE-91332 Heiligenstadt I.ofr.
Type DGS - DC Power Supplies
Type DGS - DC Power Supplies
Type DGS Category DC Power Supplies Design DC Power Supply (three-phase) Application For industrial use, e.g., to supply circuits in switchgear, dis...
DE-91332 Heiligenstadt I.ofr.
Type DTI - three-phase transformers
Type DTI - three-phase transformers
Type DTI Category Transformers Design Insulation Transformer (three-phase) Application Insulation transformers are network transformers where the ra...
DE-91332 Heiligenstadt I.ofr.
Type DSS - three-phase transformers
Type DSS - three-phase transformers
Type DSS Category Transformers Design Spar Transformer (three-phase) Application For supplying electrical consumers of all kinds. Significant saving...
DE-91332 Heiligenstadt I.ofr.
Type BSN - DC Power Supplies
Type BSN - DC Power Supplies
Type BSN Category DC Power Supplies Design DC Power Supply (single-phase) Application For general use, e.g., to supply circuits in switchgear, distr...
DE-91332 Heiligenstadt I.ofr.
Type E-UL (ETKU) - single-phase transformers
Type E-UL (ETKU) - single-phase transformers
Type E-UL (ETKU) Category Transformers Design Universal Control Transformer Isolation Transformer (single-phase) Application Isolation transformers ...
DE-91332 Heiligenstadt I.ofr.
Type E-UL (ETKU) - control transformers
Type E-UL (ETKU) - control transformers
Type E-UL (ETKU) Category Transformers Design Universal Control Transformer Isolation Transformer (single-phase) Application Isolation transformers ...
DE-91332 Heiligenstadt I.ofr.
Type DZE - throttle inductors
Type DZE - throttle inductors
Type DZE Category Chokes & Inductors Design Intermediate Circuit Choke Application The intermediate circuit choke is designed for installation in th...
DE-91332 Heiligenstadt I.ofr.
Type UTS/UTT II - single-phase transformers
Type UTS/UTT II - single-phase transformers
Type UTS/UTT II Category Transformers Design Isolation Transformer (single-phase) Network Transformer (single-phase) Application UTS For supplying e...
DE-91332 Heiligenstadt I.ofr.
Type DKE uk = 4% at 230 V - chokes-inductors
Type DKE uk = 4% at 230 V - chokes-inductors
Type DKE uk = 4 % at 230 V Category: Chokes & Inductors Design: Commutation choke (single-phase) Application: As a commutation choke for peak curren...
DE-91332 Heiligenstadt I.ofr.
Type DRT - three-phase transformers
Type DRT - three-phase transformers
Type DRT Category Transformers Design Ring-type transformer (three-phase) Application For stepless adjustment of the output AC voltage from zero to ...
DE-91332 Heiligenstadt I.ofr.
Type DNE II - choke inductors
Type DNE II - choke inductors
Type DNE II Category Chokes & Inductors Design Network Choke (single-phase) Application For peak current limitation, suppression of network feedback...
DE-91332 Heiligenstadt I.ofr.
Type EGX - DC Power Supplies
Type EGX - DC Power Supplies
Type EGX Category DC Power Supplies Design DC Power Supply (single-phase) Application As a DC power supply for general applications, e.g., for insta...
DE-91332 Heiligenstadt I.ofr.
Type DKD uk = 4% - choke inductors
Type DKD uk = 4% - choke inductors
Type DKD uk = 4 % Category Chokes & Inductors Design Commutation choke (three-phase) Application Used as a commutation choke for peak current limit...
DE-91332 Heiligenstadt I.ofr.
Type DGC - DC Power Supplies
Type DGC - DC Power Supplies
Type DGC Category DC Power Supplies Design Type DC Power Supply (three-phase) Application For general use, e.g., to supply circuits in switchgear, d...
DE-91332 Heiligenstadt I.ofr.

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store