Optical Level Switches for Hazardous Areas
Optical Level Switches for Hazardous Areas

Optical Level Switches for Hazardous Areas

Optical Level Switches for Hazardous Areas - The optical level switches UFGS…EX from EGE are ideal for detecting liquids with low dielectric constants, such as lubricating oils, hydrocarbons, or solvents. The UFGS…EX level sensors detect changes in the refractive index upon contact with the medium at the sensor tip. The sensors, featuring a stainless steel housing and glass tip, are also suitable for detecting aggressive media such as solvents. The sensors are available with Ex certifications according to ATEX and IECEx.

Keywords

Sensors
Similar products
1/15
Optical level sensors for explosive areas - Optical level sensors for explosive areas
Optical level sensors for explosive areas - Optical level sensors for explosive areas
The optical level switches are ideal for the detection of fluids with low DK value, such as lubrication oil, hydrocarbons or solvents. Optical level s...
DE-24214 Gettorf
Optical Level Detectors for Ex Zones - Optical Level Detectors for Ex Zones
Optical Level Detectors for Ex Zones - Optical Level Detectors for Ex Zones
The UFGS...EX optical level controllers from EGE are ideal for detecting low CD liquids, such as lubricating oils, hydrocarbons, or solvents. The UFGS...
DE-24214 Gettorf
Inductive Sensors for Heavy Mechanical Loads - Inductive Sensors for Heavy Mechanical Loads
Inductive Sensors for Heavy Mechanical Loads - Inductive Sensors for Heavy Mechanical Loads
EGE inductive sensors for high mechanical loads continue to operate safely and reliably after 10 impacts of 8 joules. The sensor, protected by a stain...
DE-24214 Gettorf
Level Sensors - Ultrasonic - Contactless - Level Sensors - Ultrasonic - Contactless
Level Sensors - Ultrasonic - Contactless - Level Sensors - Ultrasonic - Contactless
EGE ultrasonic sensors detect media surfaces up to 600 cm. EGE offers ultrasonic sensors for applications in humid environments with protection classe...
DE-24214 Gettorf
Level sensor - optical measuring principle - Level sensor - optical measuring principle
Level sensor - optical measuring principle - Level sensor - optical measuring principle
The optical level switches of this series are ideal for the detection of fluids with low DK value, such as lubrication oil or hydrocarbons. Optical le...
DE-24214 Gettorf
Level Controller - Optical Measurement Principle - Level Controller - Optical Measurement Principle
Level Controller - Optical Measurement Principle - Level Controller - Optical Measurement Principle
EGE level detectors with optical measurement principle have been specially designed for the detection of low epsilon liquids. This includes lubricatin...
DE-24214 Gettorf
Inductive Proximity Switches with Analog Output
Inductive Proximity Switches with Analog Output
This series complements the purely switching sensors with inductive proximity sensors featuring an analog output for measurement tasks. The analog sig...
DE-24214 Gettorf
Inductive sensors for high mechanical loads - Inductive sensors for high mechanical loads
Inductive sensors for high mechanical loads - Inductive sensors for high mechanical loads
EGE inductive sensors for high mechanical loads still work trouble-free even after 10 impacts of 8 Joule. The sensor protected by a solid stainless st...
DE-24214 Gettorf
Level Sensors down to -230° C - Level Sensors for use down to -230° C
Level Sensors down to -230° C - Level Sensors for use down to -230° C
EGE capacitive sensors for use down to -230°C reliably detect cryogenic gases or liquid granules, for example, for cryogenic grinding. The sensor's me...
DE-24214 Gettorf
Level Sensors - Conductive - Level Sensors - Conductive - for conductive fluids
Level Sensors - Conductive - Level Sensors - Conductive - for conductive fluids
Conductive level controller for the detection of conductive media. With this sensor, the resistance between two electrodes is measured. If a fluid sho...
DE-24214 Gettorf
Inductive Sensors for High Mechanical Loads
Inductive Sensors for High Mechanical Loads
Inductive sensors from EGE for high mechanical loads continue to operate safely and reliably even after 10 impacts of 8 Joules. The sensor, protected ...
DE-24214 Gettorf
Inductive proximity switches with analogue output - Inductive proximity switches with analogue output
Inductive proximity switches with analogue output - Inductive proximity switches with analogue output
In addition to purely switching sensors, your sensor specialist EGE also offers you inductive proximity switches with analogue output for measuring ta...
DE-24214 Gettorf
Level Sensors Sensors for use down to -230° C - Level Sensors Sensors for use down to -230° C
Level Sensors Sensors for use down to -230° C - Level Sensors Sensors for use down to -230° C
EGE capacitive sensors for use down to -230°C reliably detect cryogenic liquid gases or granulates, for example, for cryogenic grinding. The measuring...
DE-24214 Gettorf
Level sensor - ultrasonic - contactless - Level sensor - ultrasonic - contactless
Level sensor - ultrasonic - contactless - Level sensor - ultrasonic - contactless
EGE offers ultrasonic sensors with up to 600 cm distance from the medium surface, ultrasonic sensors for applications in humid environments in protect...
DE-24214 Gettorf
Ex-Flow Sensors - Evaluation Electronics - Evaluation Electronics for Flow Sensors for Explosive Environments
Ex-Flow Sensors - Evaluation Electronics - Evaluation Electronics for Flow Sensors for Explosive Environments
EGE evaluation electronics for ATEX flow sensors are suitable and certified for operation in explosive atmospheres. Ex flow sensors without integrated...
DE-24214 Gettorf

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play