Power Products T2000U Generator Set, equipped with a MITSUBISHI engine and a LEROY SOMER alternator.
Direct access to sections
GENERAL FEATURES
General characteristics
Description
Power table
Engine type S16R-PTAA2
Performance class G3
Frequency (Hz) 60
Reference voltage (V) 480/277
Max power ESP (kVA) 2500
Max power ESP (kWe) 2000
Max power PRP (kVA) 2272.70
Max power PRP (kWe) 1818.20
Current (A) 3007
Standard enclosure TERMINAL
Optional enclosure M80
Optional enclosure TELYS
Optional enclosure APM802
Electronic regulation
Mechanically welded chassis with anti-vibration suspensions
Radiator for temperature range 48/50°C max with mechanical fan
Fan protection grille and rotating parts (CE Option)
Exhaust compensator(s) with flanges
Starter and charging alternator 24V
Delivered with oil and coolant -30°C
User manual and commissioning guide
Voltages ESP PRP Amperes
backup
kWe kVA kWe kVA
480/277 2000 2500 1818 2273 3007
440/254 1920 2400 1745 2182 3149
ENGINE FEATURES
General data
Exhaust
Fuel
Oil
Thermal balance
Intake air
Cooling system
Emissions
Engine brand MITSUBISHI
Engine ref. S16R-PTAA2
Aspiration type Turbo
Intake air cooling Air/Air DC
Number of cylinders 16
Cylinder arrangement V
Displacement (L) 65.37
Bore (mm) 170
Stroke (mm) 180
Compression ratio 13.5 : 1
Speed (RPM) 1800
Piston speed (m/s) 10.80
ESP power (kW) 2105
Regulation class (%) +/- 0.5%
BMEP (bar) 19.30
Regulation type Electronic
Exhaust gas flow @ ESP 60Hz (L/s) 8033
Exhaust back pressure (mm H2O) 600
Consumption 110% (L/h) 522.10
Consumption 100% load (L/h) 470
Consumption 75% load (L/h) 357
Consumption 50% load (L/h) 251.50
Max fuel pump flow (L/h) 648
Oil capacity (L) 230
Min oil pressure (bar) 2.50
Max oil pressure (bar) 6.50
Oil consumption 100% load (L/h) 1.80
Oil sump capacity (L) 140
Heat rejected in exhaust (kW) 1724
Radiated heat (kW) 160
Heat rejected in water (kW) 691+638
Max intake back pressure (mm H2O) 400
Combustion air flow (L/s) 3033
Engine and radiator capacity (L) 370
Max water temperature (C°) 98
Water outlet temperature (C°) 95
Fan power (kW) 52
Fan air flow Dp=0 (m3/s) 36.30
Available back pressure on air (mm H2O) 20
Refrigerant type Glycol-Ethylene
HT thermostat (°C) 71-85
Emission PM (g/kW.h) 0.29
Emission CO (g/kW.h) 1.76
Emission HC (g/kW.h) 0.54
ALTERNATOR FEATURES
General data
Other data
Commercial brand of the alternator LEROY SOMER
Alternator ref. LSA 51.2 M60
Number of phases Three-phase
Power factor (cos Phi) 0.80
Altitude (m) 0 to 1000
Overspeed (rpm) 2250
Number of poles 4
Insulation class H
Temperature class (H/125°) continuous 40°C H / 125°K
AVR type R449
Total harmonic distortion at no load THD (%)
Waveform: NEMA = TIF
Waveform: IEC = FHT
Number of bearings 1
Direct coupling
Voltage regulation at steady state (+/- %) 0.50
Continuous rated power 40°C (kVA) 2460
Backup power 27°C (kVA) 2706
Efficiency at 100% load (%) 95.60
Air flow (m3/s) 2.80
Short circuit ratio (Kcc) 0.35
Synchronous longitudinal reactance unsaturated (Xd) (%) 357
Synchronous transverse reactance unsaturated (Xq) (%) 214
Transient time constant at no load (T'do) (ms) 2770
Saturated transient longitudinal reactance (X'd) (%) 26.80
Transient time constant in short circuit (T'd) (ms) 245
Saturated subtransient longitudinal reactance (X''d) (%) 14
Subtransient time constant (T''d) (ms) 23
Subtransient time constant (T''q) (ms) 20
Saturated subtransient transverse reactance (X''q) (%) 17.50
Unsaturated homopolar reactance (Xo) (%) 3.30
Saturated inverse reactance (X2) (%) 15.70
Armature resistance (Ra) (%) 1.40
Armature leakage reactance (Xa) (%) 8.20
Armature time constant (Ta) (ms) 41
No-load excitation current (io) (A) 1.40
Load excitation current (ic) (A) 5.50
Load excitation voltage (uc) (V) 63
Response time (Delta U = 20% transient) (ms) 700
Starting (Delta U = 20% permanent or 50% transient) (kVA) 4920
Transient Delta U 4/4 load-Cos Phi 0.8 AR (%) 11.80
No-load loss (W) 28800
Heat dissipation (W) 91000
DIMENSIONS
Dimensions compact version
Dimensions soundproof version
Length (mm) 5497
Width (mm) 2286
Height (mm) 2580
Net weight (kg) 14371
Tank capacity (L) 0
Length (mm) 0
Width (mm) 0
Height (mm) 0
Net weight (kg) 0
Tank capacity (L) 0
Sound pressure level @1m dB(A) 0
Sound pressure level @7m dB(A) 0
ENCLOSURE
TERMINAL
M80, information reporting
TELYS, ergonomic and user-friendly
APM802 dedicated to energy plant management
The enclosure serves as a simple terminal for connecting an electrical cabinet.
It offers the following features:
Emergency stop button, customer connection terminal, CE compliance.
The M80 enclosure has a dual functionality. It serves as a simple terminal for connecting an electrical cabinet and as a direct reading dashboard with dials that allow monitoring of the basic parameters of your generator set.
It offers the following features:
Engine parameters: Tachometry, Hour meter, Water temperature indicator, Oil pressure indicator, Emergency stop button, Customer connection terminal, CE compliance.
Extremely versatile, the TELYS enclosure is complete yet remains very accessible thanks to in-depth work on optimizing ergonomics and user-friendliness. With a large display screen, buttons, and a scrolling knob, it opts for simplicity and emphasizes communication.
It offers the following features:
Electrical measurements: Voltmeter, Ammeter, Frequency meter.
Engine parameters: Hour meter, Oil pressure, Water temperature, Fuel level, Engine speed, Battery voltage.
Alarms and faults: Oil pressure, Water temperature, No start, Overspeed, Min/max alternator, Min/max battery voltage, Emergency stop, Fuel level.
Ergonomics: Navigation knob between different menus.
Communication: Control and remote operation software, USB connections, PC connection.
For more information about the product and its options, please refer to the commercial documentation.
The new APM802 control panel is dedicated to the operation and monitoring of energy plants for the hospital, data center, banking, oil and gas, industrial, IPP, rental, and mining markets.
This panel is standard on all generator sets from 275 kVA intended for coupling functions. For the rest of our range, it is optional.
The human-machine interaction, designed in collaboration with a company specialized in interaction design, facilitates operation with a large 100% touch screen. The pre-configured system for energy plant applications features a unique customization function compliant with the international standard IEC 61131-3. New communication functions (automation and regulation) enhance the high availability of the installation's equipment.
Highlights:
Dedicated to energy plant management.
Ergonomics specially studied
High availability of equipment
Guaranteed modularity and sustainability
Facilitated installation extension
For more information, please refer to the commercial documentation.