The OPTIMASS 6000 is a Coriolis mass flow sensor. Combined with the MFC 400 signal converter it forms the OPTIMASS 6400 high performance Coriolis mass flowmeter for all process applications including cryogenic or high temperature media as well as high pressure fluids.
Germany
The DK46/47/48/800 is a variable area (VA) flowmeter for monitoring and adjusting extremely small flow rates of liquids and gases. It is thus particularly useful for sample flow monitoring in analyser systems and gas chromatographs or measuring liquids and gases in laboratories and pilot installations. The purgemeter operates without auxiliary power supply and is available with different glass tube and installation lengths from 90 to 325 mm / 3.55 to 12.8". The medium is visible and the flow value can be read directly off the scale at the height of the float. The glass flowmeter can be provided with max. two limit switches (NAMUR) or a 3-wire digital output. For precise setting of the flow value, the VA meter features a needle valve. The DK 46/47/48/800 is also available with a differential pressure/flow regulator to provide constant flow rates in case of varying inlet or outlet pressures. The device has approvals for use in hazardous areas.
Request for a quoteGermany
The OPTIFLUX 1000 is an electromagnetic flow sensor. Combined with the IFC 050, IFC 100 or IFC 300 signal converters it forms the OPTIFLUX 1050, OPTIFLUX 1100 and OPTIFLUX 1300 electromagnetic flowmeters for water and other conductive, non-abrasive media and OEM machinery applications.
Request for a quoteGermany
The DK32/34 is a variable area (VA) flowmeter for measuring low flow rates of liquids and gases. The tried and tested meter is particularly suitable for flow monitoring and dosing in gas analyser systems or on purge panels. Due to its robust all-metal design it can also be used in difficult process conditions with temperatures up to +200°C / +392°F or pressures up to 400 barg / 5800 psig. It is available with a metering valve as standard to accurately set the flow value. The DK32/34 operates without auxiliary power supply. The device just features a local indication with two optional MIN/MAX limit switches (NAMUR) or a reed contact. To provide constant flow rates in case of variable inlet or outlet pressures, the VA meter is also available with flow regulators. It comes with horizontal or vertical process connections for NPT or G thread and many other connection options. The VA meter has various approvals for hazardous areas.
Request for a quoteGermany
The OPTIFLUX 4000 is an electromagnetic flow sensor. Combined with the IFC 050, IFC 100 or IFC 300 signal converters it forms the OPTIFLUX 4050, OPTIFLUX 4100 and OPTIFLUX 4300 electromagnetic flowmeters for basic to advanced applications with aggressive and abrasive media or other conductive liquids.
Request for a quote