The valve isolates pumps from the system during pumps starting and stopping to protect pipe lines and pumps itself. The valve is equipped with a control solenoid valve that is switched on at pump starting and is able to fulfill pipe line gradually, reducing pressure rising peaks and allowing soft starting of the pump with closed outlet. The valve controls pump stopping as well, gradually closing before sending a closing signal to the pump. In case of casual pump stop, the valve acts also as an automatic check valve, preventing backflow over the impeller.
TECNIDRO
Italy
This valve protects pumps and pipes from pump startup and shutoff pressure surges due to power failure. Pump off means valve normally closed. If pump starting cause pressure surge, the pilot smoothly opens the valve to limit pressure rising.
Request for a quoteTECNIDRO
Italy
This valve protects pumps and pipes from pump startup and shutoff pressure surges due to power failure. Pump off means valve normally closed. If pump starting cause pressure surge, the pilot smoothly opens the valve to limit pressure rising. Quick relief valve opens due to both pressure rises and falls, fully reducing any pressure fluctuation.
Request for a quoteTECNIDRO
Italy
Available for pipes from DN50-2″ up to DN600-24″
Request for a quoteTECNIDRO
Italy
Available size: from DN300-12″ up to DN3000-120″
Request for a quote