BTA 2 – Current Transformer Low Voltage Network Measurement
BTA 2 – Current Transformer Low Voltage Network Measurement

BTA 2 – Current Transformer Low Voltage Network Measurement

Summation Current Transformer from 2 to 6 single-phase inputs Calculates the vector sum of currents from several circuits in phase. Required when the ratios of the main current transformers are not identical. Winding Current Transformer Primary currents 1 – 5A Secondary currents 1 – 5A Accuracy class: KL.0.5 Burden: 40VA (2…4 inputs) 15VA (5…6 inputs)
Similar products
1/15
TRA812 – Current Transformer Low Voltage Network, Measurement
TRA812 – Current Transformer Low Voltage Network, Measurement
Single-phase current transformer Cable entry primary Primary currents 500…1500A Secondary currents 1 – 5A Accuracy class: cl.0.5 – 1 – 3 Burden 3…15VA...
DE-16562 Hohen Neuendorf Ot Bergfelde
TRA816 – Current Transformer Low Voltage Network, Measurement
TRA816 – Current Transformer Low Voltage Network, Measurement
Single-phase current transformer Cable entry primary Primary currents 2000…5000A Secondary currents 1 – 5A Accuracy class: Class 0.5 – 1 Burden 15…25V...
DE-16562 Hohen Neuendorf Ot Bergfelde
BTV 20 – Voltage Converter
BTV 20 – Voltage Converter
Voltage Converter – AC Network Primary Voltage: 100:√3V…600V Secondary Voltage: 100 – 110V – 100:√3V – 110:√3V Load / Class: 20VA/0.5 – 50VA/3P – 10VA...
DE-16562 Hohen Neuendorf Ot Bergfelde
BTV 100 – Voltage Converter
BTV 100 – Voltage Converter
Voltage Converter – AC Network Primary Voltage: 100:√3V…600V Secondary Voltage: 100 – 110V – 100:√3V – 110:√3V Load / Class: 100VA/0.5 – 200VA/3P – 50...
DE-16562 Hohen Neuendorf Ot Bergfelde
TAQ2-M – Current Transformer Low Voltage Network, Measurement
TAQ2-M – Current Transformer Low Voltage Network, Measurement
Single-phase current transformer Winding current transformer Primary currents 5…40A Secondary currents 1 – 5A Accuracy class: Class 0.5 – 1 Burden: 2V...
DE-16562 Hohen Neuendorf Ot Bergfelde
TRA580 – Single-phase Current Transformer, Low Voltage Network, Measurement
TRA580 – Single-phase Current Transformer, Low Voltage Network, Measurement
Single-phase current transformer Cable entry primary Primary currents 250…1000A Secondary currents 1 – 5A Accuracy class: Class 0.5 – 1 Burden 1…10VA ...
DE-16562 Hohen Neuendorf Ot Bergfelde
ANTN2-3-4 – Isolation Measurement Device for IT Networks DC
ANTN2-3-4 – Isolation Measurement Device for IT Networks DC
Continuous insulation monitoring against the ground Connection to DC network up to 220V Measuring range 200kΩ or 2MΩ 2 programmable alarms Alarm types...
DE-16562 Hohen Neuendorf Ot Bergfelde
5357.13 Isolation Transformer 115V/230V
5357.13 Isolation Transformer 115V/230V
115V / 230V / 400VA...
DE-16562 Hohen Neuendorf Ot Bergfelde
TRA230 – Split Current Transformer – AC Network
TRA230 – Split Current Transformer – AC Network
Split Current Transformer – AC Network Primary Busbar 20.5 x 30.5mm Primary Current: 60…400A Secondary Current: 1-5A Burden: 1…6VA Class: 0.5 / 1 / 3...
DE-16562 Hohen Neuendorf Ot Bergfelde
Tatri 75-15 – Three-Phase Current Transformer
Tatri 75-15 – Three-Phase Current Transformer
Three-phase current transformer Rail and cable entry 14.50×24.50mm Primary currents 100 /150A Secondary current 5A Burden: 1.5VA Accuracy class: 0.5 /...
DE-16562 Hohen Neuendorf Ot Bergfelde
DGY2K/2 – Programmable DC Voltage/Current
DGY2K/2 – Programmable DC Voltage/Current
Digital display for direct current or direct voltage programmable Dimensions: Front panel 96x48mm With or without 2 programmable limit contacts, MIN a...
DE-16562 Hohen Neuendorf Ot Bergfelde
5357.1 Isolation Transformer in Enclosure
5357.1 Isolation Transformer in Enclosure
AC 230V / 230V / 400VA...
DE-16562 Hohen Neuendorf Ot Bergfelde
E7A412.3 – Plug-in Current Transformer
E7A412.3 – Plug-in Current Transformer
Calibration-capable plug-in current transformers Pass-through Ø33 Frequency: 47…63Hz – Rated voltage: 0.72kV – Test voltage: 4kV for 1 minute at 50Hz ...
DE-16562 Hohen Neuendorf Ot Bergfelde
E9A615.3 – Plug-in Current Transformer
E9A615.3 – Plug-in Current Transformer
Calibration-capable Plug-in Current Transformers Pass-through Ø53 Frequency: 47…63Hz – Rated Voltage: 0.72kV – Test Voltage: 4kV for 1 minute at 50Hz ...
DE-16562 Hohen Neuendorf Ot Bergfelde
2257.21 – High-Performance DC Voltage Regulator
2257.21 – High-Performance DC Voltage Regulator
0 – 13.8V / 0 – 100A...
DE-16562 Hohen Neuendorf Ot Bergfelde

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play